1 · The laboratory safety system: who makes the rules and which plans you must have
Simple idea: every laboratory works with things that can hurt people — blood, chemicals, fire, electricity, radiation, heavy boxes. Safety is a system: laws set the minimum, the laboratory writes plans, people are trained, equipment is checked, and every accident (even a near miss) is reported so it does not happen again.
US agencies the exam expects you to know
| Agency | What it does for laboratory safety |
|---|---|
| OSHA — Occupational Safety and Health Administration (Department of Labor) | The federal agency that enforces workplace safety law (Occupational Safety and Health Act of 1970). Writes the Bloodborne Pathogens Standard, the Hazard Communication ("Right to Know") Standard and the Laboratory (chemical hygiene) Standard. Can inspect without notice; can fine an employer (for example, for not supplying gloves). An employee may ask OSHA for an inspection. |
| CDC — Centers for Disease Control and Prevention | Publishes guidelines: Universal → Standard Precautions, biosafety levels (Biosafety in Microbiological and Biomedical Laboratories), post-exposure advice. Guidelines, not fines. |
| CAP and The Joint Commission (TJC) | Private, voluntary accrediting organizations; their inspections (often unannounced) include safety checklists. CAP requires an ergonomics program and a tuberculosis exposure control plan. |
| CMS / CLIA '88 | Quality of testing (Module 19); not the main safety enforcer. |
| EPA — Environmental Protection Agency | Hazardous (chemical) waste disposal under the Resource Conservation and Recovery Act (RCRA); registers disinfectants. |
| DOT, IATA, ICAO | Rules for packaging and shipping hazardous materials and infectious substances by road (DOT) and air (IATA/ICAO). See Section 10. |
| NFPA — National Fire Protection Association | Fire codes, the 704 hazard diamond, electrical code; adopted by local fire departments. |
| NRC — Nuclear Regulatory Commission (or the state) | Licenses and inspects the use of radioactive materials (book only). |
People and plans
- Safety officer / chair of the safety committee: implements and maintains the whole safety program (named person, even in a small laboratory). Leadership is ultimately responsible; every employee is responsible for working safely.
- Chemical hygiene officer (CHO): required by OSHA; gives technical guidance for the chemical hygiene plan.
- Mandated written plans: chemical hygiene plan (CHP) and bloodborne-pathogen exposure control plan (both OSHA, since 1991) · tuberculosis exposure control plan (CAP, following CDC) · ergonomics program (CAP) · waste management plan · emergency/disaster (fire, pandemic, bioterrorism) plans.
- Training: at hire (before working with the hazard) and at least yearly; safety manual given to every new employee; training documented. SDSs and safety documents reviewed yearly.
- Incident (occurrence) reports: for every injury, exposure and near miss — the aim is prevention, not blame. Records are kept, not thrown away after review.
- Safety inspections/audits: internal team on a schedule; external inspectors (OSHA, CAP, TJC, state, fire department) may come unannounced.
Hierarchy of controls (best → weakest)
Tietz 7th ed., Ch 15 Principles of Basic Techniques and Laboratory Safety, p. 199.e15 (OSHA 1970, CDC, JC/CAP, key elements, safety officer, CHO, safety manual), p. 199.e16 (PPE duty, inspections unannounced, CHP and exposure control plan 1991, TB plan), p. 199.e17 (ergonomics program required by CAP), p. 199.e21 (EPA/RCRA), p. 199.e25 (safety elements); book only: hierarchy-of-controls wording, NRC.
2 · Bloodborne pathogens, the chain of infection and Standard Precautions
Simple idea: we cannot know which patient specimen is infectious, so we treat every specimen as if it carries HIV, hepatitis B virus (HBV) or hepatitis C virus (HCV).
Chain of infection — break any link and infection stops
Hand hygiene is the simplest and most effective way to break the chain. Vaccination makes the host non-susceptible (HBV). Engineering controls block transmission.
From Universal to Standard Precautions
| Name | Year | Covers |
|---|---|---|
| Universal Precautions (UP) | 1987 (CDC) | Blood and body fluids containing visible blood |
| Body substance isolation | later 1980s | All moist body substances (gloves for any moist fluid) |
| Standard Precautions | 1996 (CDC; updated 2007) | Blood and ALL body fluids, secretions and excretions except sweat, non-intact skin and mucous membranes; gloves for any moist body fluid AND hand hygiene after removing gloves; also respiratory hygiene, sharps safety, cleaning/disinfection |
| Transmission-Based Precautions | — | Extra layer for contact, droplet or airborne spread (added to, never instead of, Standard Precautions) |
OSHA Bloodborne Pathogens Standard (29 CFR 1910.1030)
- Written exposure control plan: purpose, scope, references, definitions, responsibilities and procedures; reviewed at least yearly; employees involved in choosing safer devices.
- Exposure determination: every job classified — all employees exposed / some exposed / not exposed (Tietz Groups I, II, III).
- HBV vaccine offered free to every employee with occupational exposure (within 10 working days of assignment; employee may decline in writing and still have it later). Exempt: already vaccinated, immune by antibody test, or medical contraindication.
- Employer provides, cleans, repairs and replaces PPE at no cost; free training during working hours, at hire and yearly.
- Post-exposure evaluation and follow-up at no cost; medical records kept for duration of employment + 30 years (confidential).
- Needlestick Safety and Prevention Act (2000): engineered sharps-injury protection must be used and a sharps injury log kept.
- Biohazard labels/symbol on containers of regulated waste, refrigerators and freezers with blood, and shipping containers. Tietz: no special warning label is put on individual patient specimens — all are treated as hazardous.
Occupational risk
| Agent | Risk after one needlestick from an infected source (approximate) | Prevention |
|---|---|---|
| HBV | Highest: about 6–30% if not immune | Vaccine (offered free) |
| HCV | About 1–2% (lower in recent studies) | No vaccine; early follow-up testing |
| HIV | About 0.3% (mucous membrane ≈ 0.1%) | Post-exposure prophylaxis |
Most laboratory-acquired bloodborne infections follow parenteral inoculation (needlestick, cut). Viral hepatitis (HBV) is the classic major job-related infectious hazard. Intact skin is a good barrier.
Tietz 7th ed., Ch 15, p. 199.e17 (exposure control plan sections, Groups I–III, sharps log), p. 199.e19 (exposure routes, Universal → Standard Precautions 1996, all fluids except sweat), p. 199.e20 (Transmission-Based Precautions, no labels on patient specimens), p. 199.e21 (HBV vaccine offered free); book only (SUCCESS!, Concise Review, Strasinger): chain of infection, 10-day vaccine rule, 30-year records, risk percentages.
3 · Personal protective equipment, hand hygiene and safe work practices
PPE — what, when, why
| Item | Rules |
|---|---|
| Gloves | Single-use, disposable (nonsterile latex or other) for specimens; change between patients and when torn or contaminated; never washed and reused. Latex allergy → nitrile, vinyl, neoprene or powder-free low-allergen latex. Chemicals: choose the glove by the chemical and the task (nitrile/neoprene resist many chemicals). Heat-resistant gloves for hot glass and dry ice. Cut-resistant for sharp work. |
| Laboratory coat/gown | Fluid-resistant, long sleeves with snug cuffs, closed (buttoned/zipped) front. Removed before leaving the laboratory; never worn in break rooms or cafeteria; laundered by the employer. |
| Eye and face | Goggles, safety glasses with side shields, face shield, or work behind a splash shield whenever splashes or caustic/toxic chemicals are possible. Contact lenses are not eye protection and can trap irritants. |
| Respirator | Fit-tested N95 (or better) for airborne agents such as Mycobacterium tuberculosis; a surgical mask is not enough. |
| Shoes | Closed-toe, fluid-resistant, covering the whole foot (no sandals, no cloth/mesh). |
Hand hygiene — the single most effective infection-control measure
- Wash after removing gloves, before leaving the laboratory, before eating, after any contamination.
- Technique: wet with warm water → soap → lather and rub all surfaces (≥ 15–20 seconds) → rinse with fingers pointing down → dry with paper towel → turn the faucet off with the paper towel.
- Alcohol hand rub is fine for clean hands, but visibly soiled hands need soap and water.
Safe work practices
- No eating, drinking, smoking, applying cosmetics or lip balm, or handling contact lenses in the work area. No food in laboratory refrigerators (label them).
- Never mouth pipette — use mechanical pipetting devices. Do not mix infectious fluids by bubbling air through them.
- Tie back long hair; no dangling jewelry, loose sleeves or ties. Do not run.
- Keep hands away from mouth, nose and eyes. Do not use the "clean area" phone with gloves; remove gloves and wash before touching clean areas.
- Do not bend, break, shear or recap used needles; discard needles and syringe as a unit into a sharps container immediately.
- Disinfect the bench at the end of work and after spills. End-of-shift order: disinfect the work area → remove gloves → remove coat → wash hands.
- Uncap tubes away from the face (behind a shield, with gauze); centrifuge tubes capped; open the centrifuge only after it stops.
Tietz 7th ed., Ch 15, p. 199.e16 (PPE, eye protection, contact lenses, heat-resistant gloves), p. 199.e20 (barrier list, nonlatex gloves, mouth pipetting, bubbling air, hand washing, protective clothing removed on leaving), p. 199.e25 (BSC); Ch 99 Allergy, p. 1357.e24 (latex allergy in health care workers); book only: donning/doffing order, hand-washing steps (Strasinger Ch 1).
4 · Needlesticks, splashes, blood spills and disinfection
Exposure incident — what to do FIRST
A few drops on a glove: change the gloves and wash hands — do not wash or disinfect gloves and keep using them.
Blood spill clean-up
- Sodium hypochlorite inactivates HBV and HIV; the 1:10 dilution of household bleach (≈ 0.5% hypochlorite) is the classic exam answer. Diluted bleach loses strength — make it fresh (commonly daily).
- Always follow the manufacturer's directions for a new disinfectant — a stronger mix is not "better" and may not work.
- Broken glass: never pick up with hands — use a brush and dustpan or forceps.
- Prions (transmissible spongiform encephalopathy agents) resist the usual disinfection and sterilization rules and need special procedures.
- Sterilization (kills all life, including spores): autoclave (moist heat under pressure, classically 121 °C, 15 psi) or incineration. Disinfection removes most pathogens but not all spores.
Tietz 7th ed., Ch 15, p. 199.e20 (decontaminate surfaces with EPA-registered hospital disinfectants; CLSI M29), p. 199.e21 (clean freezers with gloves and respiratory protection); book only (SUCCESS! §III, BOC, Concise Review, CLSR): 1:10 bleach, PEP timing, first-aid sequence, prions, autoclave conditions.
5 · Biosafety levels, biological safety cabinets, fume hoods, centrifuges and waste
Biosafety levels (CDC/NIH)
| Level | Agents | Example |
|---|---|---|
| BSL-1 | Not known to cause disease in healthy adults | Teaching strains |
| BSL-2 | Human disease that is rarely serious; prevention or treatment often available | Most clinical laboratories (blood, routine cultures) |
| BSL-3 | Serious or lethal disease, spread by aerosols; treatment may exist | Culture work with M. tuberculosis, dimorphic fungi such as Coccidioides (cultures) |
| BSL-4 | Dangerous/exotic agents, high risk of aerosol infection, no reliable treatment | Ebola (only special centers such as the CDC) |
Cabinets and hoods — protect whom?
| Device | Air flow | Protects |
|---|---|---|
| BSC Class I | Room air drawn in at the open front, out through a HEPA filter | Worker + environment (not the product) |
| BSC Class II (most common) | Inward air at front + HEPA-filtered air flowing DOWN over the work; Class II A returns filtered air into the room, Class II B ducts it outside | Worker + environment + product — the most useful safety device in microbiology |
| BSC Class III | Gas-tight box, work through glove ports | Maximum (BSL-4) |
| Horizontal laminar-flow "clean bench" | Blows filtered air toward the worker | Product only — never for infectious material |
| Chemical fume hood | Ducted; all air exhausted outside the building | Worker from chemical vapors — NOT from microbes; not a storage cabinet |
- HEPA = high-efficiency particulate air filter; catches particles and aerosols but not chemical vapors (chemicals can also damage it). BSCs need regular certification and airflow checks.
- Laboratories (especially microbiology) are kept at negative pressure to offices, so air flows into the lab, not out.
- Aerosol sources: centrifuging uncapped tubes, opening a centrifuge before it stops, popping stoppers, splashing, vortexing open tubes, flaming loops. Before centrifuging: inspect tubes for cracks and cups for glass; balance the load; use safety cups/sealed rotors; clean spills with disinfectant.
- Tuberculosis control: specimens from TB patients reach every section, including chemistry. Processing in a BSC; culture work at BSL-3; N95 respirator; employee screening.
Waste
- Separate infectious from non-infectious waste at the source. Red/orange biohazard bags for non-sharp infectious waste (tubes, contaminated gauze, gloves); ordinary trash for paper wrappers and clean packaging.
- Sharps (needles, lancets, broken contaminated glass, slides, pipettes): rigid, puncture-resistant, leak-proof, labeled container; close when about ¾ full.
- Regulated medical waste = infectious waste; treated by autoclave or incineration before disposal; regulated by state rules.
- Chemical hazardous waste: EPA rules (RCRA, "cradle to grave"), licensed hauler, never into biohazard bags.
Tietz 7th ed., Ch 15, p. 199.e18–e19 (biological hazards, centrifuge accidents), p. 199.e20–e21 (inspect tubes and trunnion cups, red-bag disposal, BSL-2 procedures), p. 199.e16 (fume hood uses), p. 199.e23 and p. 199.e25 (risk groups, HEPA recirculation for risk groups I–II, not for III–IV); Ch 86 Mycobacteriology, p. 1203.e3 (M. tuberculosis cultures at BSL-3); Ch 87 Mycology, p. 1204.e15 (BSL-2 class II cabinet; dimorphic fungi BSL-3); book only: BSC class details, horizontal clean bench, negative pressure, ¾-full rule.
6 · Chemical hazard communication: labels, SDS, NFPA diamond and exposure limits
Two OSHA chemical standards
| Standard | Main points |
|---|---|
| Hazard Communication Standard (HCS, 29 CFR 1910.1200; "Right to Know"; extended to hospitals 1988; aligned with the UN Globally Harmonized System, GHS, in 2012) | Workers have a right to know the hazards of the chemicals they use. Manufacturers classify chemicals and supply labels and Safety Data Sheets (SDS); employers keep an inventory, keep SDSs accessible on every shift, label containers and train workers. |
| Laboratory Standard (Occupational Exposure to Hazardous Chemicals in Laboratories, 29 CFR 1910.1450) | Written chemical hygiene plan: SOPs, control measures (fume hoods checked, PPE), training, medical consultation, operations needing prior approval, extra protection for select carcinogens, reproductive toxins and highly toxic chemicals, and a designated chemical hygiene officer. Chemical inventory updated yearly. Exposure monitoring when there is reason to think limits are exceeded. |
GHS label (from the manufacturer)
Product identifier · signal word ("Danger" = more severe, "Warning" = less severe) · hazard statements · precautionary statements · supplier details · pictograms (black symbol in a red-bordered diamond). OSHA enforces 8 pictograms; the environment pictogram is optional.
| Pictogram | Means |
|---|---|
| Flame | Flammables, pyrophorics, self-heating, emits flammable gas |
| Flame over circle | Oxidizers |
| Exploding bomb | Explosives, self-reactives, organic peroxides |
| Skull and crossbones | Acute toxicity (fatal or toxic) |
| Corrosion | Skin corrosion/burns, eye damage, corrosive to metals |
| Health hazard (person with star on chest) | Carcinogen, mutagen, reproductive toxin, respiratory sensitizer, target-organ toxicity |
| Exclamation mark | Irritant (skin/eye), skin sensitizer, harmful (less severe) toxicity, narcotic effects |
| Gas cylinder | Gases under pressure |
Safety Data Sheet (SDS, formerly MSDS) — 16 standard sections
1 Identification · 2 Hazard(s) identification · 3 Composition · 4 First-aid measures · 5 Fire-fighting · 6 Accidental release (spills) · 7 Handling and storage · 8 Exposure controls/PPE (exposure limits) · 9 Physical/chemical properties · 10 Stability/reactivity · 11 Toxicology (carcinogenic potential) · 12–15 ecological, disposal, transport, regulatory (not enforced by OSHA) · 16 Other. An SDS never lists the price. First stop for "how do I dispose of / store / treat exposure to this chemical?"
NFPA 704 diamond (for emergency responders)
| Position | Color | Hazard |
|---|---|---|
| Left | Blue | Health |
| Top | Red | Flammability |
| Right | Yellow | Reactivity (instability) |
| Bottom | White | Special information (e.g., W with a line = water-reactive, OX = oxidizer) |
Each colored part carries a number 0 (minimal) to 4 (severe). A "slightly toxic" chemical = 1 in blue. The diamond does NOT show biohazards. Placed on doors, buildings and tanks so firefighters can see it. (HMIS is a similar color bar system.)
Hazard words and exposure limits
- Carcinogen causes cancer (formaldehyde, benzene) · mutagen changes DNA · teratogen causes birth defects · corrosive destroys tissue at the contact site (strong acids/bases) · toxic harms by ingestion, inhalation or skin absorption · irritant causes reversible inflammation.
- PEL (permissible exposure limit, OSHA, legal), usually an 8-hour time-weighted average · TLV (threshold limit value, ACGIH) = amount a worker may be exposed to in one 8-hour day without harm · STEL = 15-minute short-term limit · action level = point that triggers monitoring. Lower TLV = more toxic chemical.
- Formaldehyde (OSHA standard): PEL 0.75 ppm (8 h), STEL 2 ppm, action level 0.5 ppm; repeat monitoring when procedures or equipment change.
- Symptoms after chemical exposure (e.g., repeated headaches): report to the supervisor; the employer provides a medical consultation at no cost and without loss of pay.
Tietz 7th ed., Ch 15, p. 199.e15 (HCS 1988 "Lab Right to Know"), p. 199.e16–e17 (CHP elements, yearly inventory, SDS 16 sections, sections 12–15 non-mandatory, GHS), p. 199.e19 (OSHA eight pictograms + optional environment; NFPA 704 0–4, three colored quadrants and special fourth); Concise Review Ch 11 (Laboratory Standard elements, formaldehyde limits); book only: signal words, TLV/PEL definitions, HMIS.
7 · Handling, storing and disposing of chemicals; chemical spills and first aid
Handling
- Always add acid to water, slowly, while mixing (in the sink for cooling) — never water to concentrated acid (it boils and spatters). "Do what you oughta, add acid to water."
- Carry glass bottles in rubber/plastic carriers; hold a bottle by its body, never by the neck; use a cart for heavy or many bottles.
- Label the container before filling it: name, concentration, preparer's initials, date (and expiry, storage). Discard reagents found in unlabeled bottles. A portable container used immediately by the person who filled it is exempt from labeling.
- Volatile, toxic or carcinogenic chemicals: use in the fume hood; gloves, eye protection; respirator if needed.
- Strong acids/caustics: dispense with a pump or automatic dispenser; never mouth pipette.
Storage
- Store by compatibility, never alphabetically. Keep acids away from bases, flammables away from oxidizers and acids, and never mix bleach (chlorine) with ammonia (toxic chloramine gas).
- Large and heavy bottles on low shelves (never above head height).
- Flammables: approved vented flammable-storage cabinet; small working amounts in approved safety cans (≤ 5 gallons, spring-closing lid and flame arrester); refrigerate only in explosion-proof (flammable-safe) refrigerators — the light switch or thermostat of an ordinary refrigerator can ignite vapors. Fume hoods are not storage areas. Tietz: no more than 60 gallons of the most flammable classes per cabinet.
- Dangerous-on-ageing chemicals: picric acid becomes shock-sensitive (explosive) if it dries out with age; diethyl ether forms explosive peroxides on long contact with air; perchloric acid explodes with organic material (no wooden benches; special wash-down hoods); sodium azide (reagent preservative) forms explosive copper/lead azides in drain pipes — flush with large volumes of water or collect as waste; mercury vapor is toxic — clean every droplet with a mercury kit (best: avoid mercury).
Spills
Large or highly toxic spill (e.g., gallons of formaldehyde): evacuate the area first, alert others and the emergency team; clean-up only by trained responders with respirators
Chemical first aid
- Skin: remove contaminated clothing and flush with large amounts of water (safety shower for large areas) for 15 minutes; do NOT neutralize an acid with a base on the skin; no ointments.
- Eyes: eyewash at once for 15 minutes, holding the eyelids open; then medical care. Eyewash stations and showers must be inspected and flushed regularly.
- Take the SDS (product information) to the doctor.
Disposal
Never pour flammable or toxic solvents down the drain. Collect in safety cans (Tietz: separate cans for ether and for chlorinated solvents) and dispose of as EPA hazardous waste through a licensed waste hauler. Small amounts of water-miscible, non-hazardous chemicals may go down the drain with plenty of water if local rules allow. Consult the SDS for disposal of old reagents.
Tietz 7th ed., Ch 15, p. 199.e21 (carry bottles in rubber/plastic containers, never by neck, acid slowly into water in the sink, label before adding reagent, label contents, discard unlabeled bottles, dispensers, perchloric acid, mercury, EPA RCRA, solvents in fume hood), p. 199.e22 (approved vented metal cabinet, 5 gallons per room, 60 gallons per cabinet, solvent disposal and separate cans), p. 199.e16 (spill kits); book only (SUCCESS! §III): picric acid, sodium azide, ether peroxides, spill steps, chlorine–ammonia, 15-minute flush, secondary-container exemption.
8 · Fire safety: flash point, fire classes, extinguishers, RACE and PASS
Simple idea: fire needs fuel, heat and oxygen (plus the chain reaction). Remove one and the fire stops. A flammable liquid does not burn — its vapor burns.
- Flash point = the lowest temperature at which a liquid gives off enough vapor to form an ignitable mixture with air just above its surface. Traditional rule: flammable < 100 °F (37.8 °C), combustible ≥ 100 °F. Volatility is shown by the boiling point. Xylene, ethanol, methanol and acetone are common flammable laboratory liquids.
- Pyrophoric materials ignite by themselves in air (e.g., potassium metal with moisture).
| Class | Fuel | Use | Never |
|---|---|---|---|
| A | Ordinary combustibles: paper, wood, cloth (a burning lab coat), rubber, plastics | Water, dry chemical, foam | — |
| B | Flammable liquids and gases: solvents, oil, grease, paint thinner | Dry chemical, CO₂, foam | Water (spreads the fire) |
| C | Energized electrical equipment (instruments, electrophoresis units, computers) | CO₂, dry chemical, clean-agent (Halon-type) gas | Water or foam (shock) |
| D | Combustible metals: magnesium, sodium, potassium, lithium, titanium | Special dry powder (trained staff) | Water |
| K | Cooking oils/fats (kitchens) | Wet chemical | Water |
- Multipurpose ABC dry-chemical extinguisher = the usual laboratory extinguisher. Gaseous agents (Halon 1301 or modern clean agents, CO₂) leave no residue — preferred for computer/instrument rooms.
- Electrical fire: if power is switched off at the source it becomes a class A or B fire.
- Extinguishers by every laboratory door; inspected regularly; only trained staff use them.
- Person on fire: stop, drop and roll, fire blanket, or safety shower.
- Exits and corridors always clear; fire alarm locations known; unannounced fire drills; evacuation maps posted. Labs with explosion risk need a second exit.
- Tietz also mentions a "type E" fire (cannot be put out, e.g., explosives store — let it burn while protecting surroundings); US references use class K instead.
PASS — Pull the pin → Aim at the base of the fire → Squeeze the handle → Sweep side to side
Tietz 7th ed., Ch 15, p. 199.e22 (flash point definition, vapor too lean below it; NFPA/OSHA fire codes; safety shower pull ring; fire blanket; dry chemical all-purpose; extinguisher near every door; training), p. 199.e23 (Table 15.13 classes A, B, C and combinations; type D powdered metals; type E; Halon 1301 in computer rooms); book only (SUCCESS! §III, Strasinger Ch 1): 100 °F rule, class K, RACE, PASS, pyrophoric potassium.
9 · Electrical, compressed gas, cryogenic, radiation and ergonomic hazards
Electrical
- All equipment grounded (three-prong plug) or double insulated; UL (or equivalent) listed; checked for electrical safety when new and after repair.
- No multi-outlet "gang" adapters; Tietz: extension cords prohibited (only temporary, short, heavy-gauge, UL-approved, single outlet). Power strips with their own breaker mounted above bench level.
- Replace frayed cords at once (never tape them). Never handle equipment with wet hands; if liquid is spilled on an instrument, turn it off and dry it. Unplug, tag out and report equipment that gives even a small shock ("tingle").
- Repairs only with the instrument unplugged.
- Shocked person: do NOT touch them while they are in contact with the current — first turn off the circuit breaker or unplug the instrument, or push the source away with a non-conducting object (wood, glass); then call for help and start CPR if needed.
Compressed gases and cryogens
- Cylinders stored and used upright, chained/strapped to a wall or bench, even when empty; moved only on a hand truck with the cylinder secured and the valve cap on; never rolled or dragged. Check the contents label before connecting; never force a regulator thread. Store away from flammable liquids and heat.
- Liquid nitrogen and dry ice: very cold burns and displacement of oxygen — insulated (cryogenic) gloves, face shield, cover skin, good ventilation; never seal dry ice in an airtight container (CO₂ pressure can burst it).
Radiation (book only)
- Principle ALARA — as low as reasonably achievable: minimize time, maximize distance, use shielding.
- Radiation symbol: magenta/black three-bladed trefoil on yellow. Workers wear dosimeter badges; pregnant workers should not work with radioisotopes (or follow special limits). Radioactive waste goes to a separate, labeled container.
- Tietz: a β-emitter such as ³²P is more hazardous than ³H because its particles carry more energy; γ-rays are very penetrating and harder to shield.
Ergonomics and physical hazards
- Repetitive motion, awkward posture and force (pipetting, keyboard, microscope) cause musculoskeletal disorders (e.g., carpal tunnel syndrome). Keep wrists neutral, adjust the workstation, take breaks, use ergonomic pipettes. Report pain to the supervisor early.
- Lifting: bend at the knees and hips, keep the load close, tighten abdominal muscles, lift with the legs, do not twist.
- Do not run in the laboratory; keep floors dry and aisles clear.
Tietz 7th ed., Ch 15, p. 199.e22 (grounding with three-prong plugs, NEC, extension cords prohibited, power strips above bench, wet hands, unplug and leave a note; compressed gas rules: hand truck, valve cap, secured cylinders, check contents, never force threads), p. 199.e12 (β- and γ-emitter hazard), p. 199.e17 (ergonomics risk areas), p. 199.e21 (dry ice chests); book only (BOC, Strasinger Ch 1): shock rescue, ALARA, badges, lifting.
10 · Transport of specimens: inside the hospital, to a referral laboratory, and shipping infectious substances
Inside the facility
- Specimens travel capped, in a leak-proof biohazard-labeled bag with the request form in a separate outer pocket (paper never inside with the tube). Carriers are rigid and can be disinfected.
- Pneumatic tube systems can cause hemolysis (↑ plasma hemoglobin, potassium, LD, AST) if tubes are not full or move inside the carrier, or if the route has sharp curves and sudden stops. Blood gas samples (PO₂ changes from air bubbles) and samples for some platelet function/viscoelastic tests, and specimens with very fragile cells (e.g., leukemia, chemotherapy), should be hand-carried or centrifuged first.
- Time and temperature: some tests need the specimen on ice (ammonia, lactate, pyruvate, ACTH, gastrin, renin, blood gases in some settings); protect bilirubin/carotene/some drugs from light; separate serum or plasma from cells within about 2 hours; if centrifugation is delayed, keep blood at room temperature (cold makes potassium leak out of red cells).
- Specimens from remote sites must be processed (separated, preserved) at the collection site before courier transport.
To a referral (reference) laboratory
- The referring laboratory checks the referral laboratory's quality (CAP: obtain its CLIA certificate) and follows its specimen requirements; referral results are identified as such in the record.
- Assume transit may take up to 72 hours; avoid shipping just before weekends/holidays; keep an aliquot for retesting when possible.
- Containers: leak-proof polypropylene or polyethylene with a screw cap (Teflon-lined); avoid glass; polystyrene cracks when frozen. Air transport may expose packages to about half normal air pressure, vibration and temperature extremes.
- Frozen specimens: insulated Styrofoam box (walls about 1 inch thick) with dry ice, specimen buried in the dry ice, box vented (never airtight). Dried blood spots: paper envelope, kept dry; rapid shipping rarely needed.
Shipping infectious substances (DOT 49 CFR, IATA Dangerous Goods Regulations)
| Category | Definition | UN number / marking |
|---|---|---|
| Category A | Can cause permanent disability or life-threatening/fatal disease in otherwise healthy people or animals on exposure (e.g., cultures of M. tuberculosis, B. anthracis, Coccidioides; Ebola specimens) | UN 2814 "Infectious substance, affecting humans" (UN 2900 animals only); Division 6.2 infectious-substance label; shipper's declaration for dangerous goods |
| Category B | Infectious substances that do not meet Category A — most routine patient specimens sent for diagnosis | UN 3373 "Biological substance, Category B" (diamond mark) |
| Exempt | Specimens with minimal likelihood of containing pathogens (e.g., routine chemistry on a healthy person) | "Exempt human specimen"; still triple packaging |
- Only trained (and certified by the employer) staff may package and ship hazardous materials: DOT HAZMAT training at least every 3 years; IATA every 2 years. Violations bring large fines for the person and the employer.
- Airlines treat dry ice as a hazardous material, so even ordinary frozen specimens fall under the rules.
- Treat every specimen as if it were infectious when packaging, even if it is not a known etiologic agent.
Tietz 7th ed., Ch 4 Specimen Collection and Processing, p. 77 (on-ice tests, light protection, remote processing, separation within 2 h, room temperature if delayed), p. 78 (pneumatic tube hemolysis, PO₂, fragile cells, referral laboratory CLIA certificate, 72 h, weekends, 0.50 atm, containers, polystyrene, Styrofoam 1 inch, dry ice, vented box), p. 79 (treat all specimens as regulated, airlines and dry ice, IATA training); Ch 15, p. 199.e18 (UN classes, DOT 2002 rule), p. 199.e21 (DOT/IATA/ICAO HAZMAT training, shipper's declaration, fines); Ch 87 Mycology, p. 1204.e15 (Category A vs B by severity; Coccidioides culture Category A); book only (current DOT 49 CFR 173.199 and IATA): UN numbers, 95 kPa, absorbent, training intervals, exempt specimens.
11 · Signs, symbols, ISO 15190 and exam traps
Signs and symbols
| Sign/symbol | Meaning |
|---|---|
| OSHA "DANGER" sign — red, black and white | Immediate hazard; special precautions required |
| OSHA "CAUTION" — yellow and black | Potential hazard; be careful |
| Safety instruction — green and white | General safety information (e.g., location of eyewash) |
| Biohazard symbol — three interlocking crescents (trefoil), fluorescent orange or red-orange | Biological (infectious) hazard: specimens, regulated waste, refrigerators with blood |
| Radiation trefoil — magenta/black on yellow | Radioactive material |
| NFPA 704 diamond (blue, red, yellow, white) | Chemical hazards for emergency responders |
| GHS pictograms (red-bordered diamonds) | Chemical hazard classes on labels and SDSs |
| DOT/UN shipping labels (diamond, class number 1–9 in the bottom corner) | Hazard class during transport; lost when the inner containers are unpacked → the laboratory must label each container |
UN hazard classes (DOT labels)
1 Explosives · 2 Gases (compressed) · 3 Flammable liquids · 4 Flammable solids · 5 Oxidizers · 6 Toxic and infectious substances (6.2 = infectious) · 7 Radioactive · 8 Corrosives · 9 Miscellaneous (e.g., dry ice).
International view — ISO 15190 (medical laboratories — safety)
Voluntary standard linked to ISO 15189: designated safety officer, hazard identification, incident reporting, training, PPE, safe work practices, aerosols, safety cabinets for risk groups I–II, chemical, radiation and fire safety, emergency evacuation (annual fire drill), electrical equipment, sample transport and waste disposal; at least yearly safety audits. It does not cover containment work with risk group III–IV pathogens.
Exam traps — quick list
- "Which is PPE?" → something worn (lab coat, gloves). Cabinets, showers, eyewashes, sharps containers = engineering controls.
- OSHA enforces; CDC recommends; TJC/CAP accredit voluntarily.
- Highest bloodborne risk = HBV; vaccine free.
- First aid always before paperwork; paperwork (incident report) always — including near misses.
- Fume hood ≠ biological safety cabinet. Class II BSC = downward HEPA air.
- NFPA 4 = worst; blue = health; the diamond has no biohazard part.
- Acid into water; label before filling; store by compatibility, not alphabetically.
- Electrical fire = class C (no water); burning coat/paper = class A.
- Category B = UN 3373; Category A = UN 2814; triple packaging; dry ice vented.
Tietz 7th ed., Ch 15, p. 199.e18–e19 (UN nine classes, DOT labels lost on unpacking, GHS/NFPA), p. 199.e23–e24 (ISO 15190, Table 15.14, risk groups III–IV excluded); book only (BOC, Strasinger Ch 1): OSHA sign colors (29 CFR 1910.145), symbol colors.
⚡ Last-Minute Review — Laboratory Safety & Specimen Transport
1. System
- OSHA enforces (Bloodborne Pathogens, Hazard Communication "Right to Know", Laboratory/chemical hygiene standards; inspections, fines). CDC guidelines. CAP/TJC voluntary accreditation (CAP: ergonomics + TB plans). EPA chemical waste. DOT/IATA shipping. NFPA fire codes + diamond.
- Safety officer runs the program; chemical hygiene officer for the CHP. Required plans: CHP, exposure control plan, TB, ergonomics, waste, disaster.
- Controls: engineering (BSC, hood, sharps box) → work practice (no recapping, hand hygiene) → PPE (gloves, coat, eye/face, N95) last. Incident report for every injury, exposure and near miss.
2. Biological
- Standard Precautions (1996): all blood and body fluids except sweat. HBV highest risk (≈ 6–30%), HCV ≈ 1–2%, HIV ≈ 0.3%. HBV vaccine free (10 working days), declination allowed. Records employment + 30 years. Sharps log.
- Hand hygiene = most effective; rinse fingers down; faucet off with towel. No mouth pipetting, food, cosmetics, contacts. Coat off before leaving. End of shift: disinfect → gloves off → coat off → wash.
- Needlestick: wash with soap and water → report → evaluation → PEP within hours (not after 72 h). Eye splash: eyewash 15 min. Drops on gloves: change gloves, wash hands.
- Blood spill: PPE → absorb → clean → 1:10 bleach (fresh) → biohazard waste. Prions resist routine decontamination.
- BSL-2 = most clinical labs; BSL-3 = TB/dimorphic fungus cultures (N95); BSL-4 = exotic. Class II BSC = HEPA air downward (IIA back to room, IIB outside). Fume hood = chemicals only, all air outside. Lab negative pressure.
- Centrifuge: capped, balanced, wait until stopped. Sharps container rigid, puncture-proof, ¾ full. Separate infectious and non-infectious waste.
3. Chemical
- GHS label: signal word (Danger > Warning), pictograms; exclamation mark = irritant; health hazard = carcinogen; skull = acute toxicity; flame over circle = oxidizer. SDS 16 sections (4 first aid, 8 PPE/limits) — never cost.
- NFPA: blue health (left), red flammability (top), yellow reactivity (right), white special (bottom); 0–4 (4 worst); no biohazard.
- TLV/PEL = 8-hour limit; lower = more toxic. Formaldehyde PEL 0.75 ppm, STEL 2, action level 0.5.
- Acid to water; label before filling; carry in rubber carriers; store by compatibility; flammables in vented cabinet/safety can ≤ 5 gal/explosion-proof refrigerator; picric acid (dry → explosive), ether (peroxides), azide (explosive metal salts in drains), perchloric (organics), chlorine + ammonia (toxic gas).
- Skin/eye chemical: water 15 min, no neutralizing. Big toxic spill: evacuate first. Solvent waste: EPA hazardous waste, licensed hauler, never down the sink.
4. Fire, electrical, gas, radiation
- Flash point = lowest temperature giving an ignitable vapor; flammable < 100 °F. A paper/cloth, B liquids, C electrical, D metals, K kitchen. ABC dry chemical = lab standard; no water on B/C. RACE (Rescue, Alarm, Contain, Extinguish/Evacuate); PASS (Pull, Aim at base, Squeeze, Sweep).
- Grounded 3-prong plugs; no gang adapters/extension cords; tag out shocking equipment; shocked person — cut power first.
- Cylinders upright, chained, valve cap on, hand truck. Liquid N₂: face shield + cryo gloves. Radiation: time, distance, shielding (ALARA); badges; pregnancy.
- Ergonomics: neutral wrists; lift with knees/hips/legs.
5. Transport
- Biohazard bag + request in outside pocket. Pneumatic tube → hemolysis (K, LD, AST ↑), PO₂ errors; hand-carry fragile/blood gas samples.
- On ice: ammonia, lactate, pyruvate, ACTH, gastrin, renin. Light: bilirubin. Separate ≤ 2 h; if delayed keep at room temperature (not 4 °C — K leaks).
- Referral: check CLIA certificate; up to 72 h; no weekend shipping; polypropylene, not glass or polystyrene; Styrofoam + dry ice, vented.
- Category A = UN 2814 (cultures of dangerous agents); Category B = UN 3373 (most specimens). Triple packaging: leak-proof primary + absorbent + leak-proof secondary + rigid outer; list between secondary and outer; dry ice UN 1845. Trained shippers only (DOT 3 y, IATA 2 y).