Press ✓ Mark section complete at the end of each section after you study it. Opening the page does not mark anything. Tap a chip to jump. Labels: 🔥 very high-yield · 📌 must memorize · ⚠️ exam trap · 🧠 memory trick · 🔬 lab connection · 💡 understand this.
1 · Concentrations, solutions and unit conversions
Simple idea: every concentration answers one question — how much substance is in how much solution? The units change (grams, moles, equivalents; 100 mL, 1 L, 1 kg), but the logic is always amount ÷ volume (or mass).
The main ways to express concentration
| Expression | Meaning | Example |
|---|---|---|
| % w/v | grams of solute per 100 mL of solution | 0.9% NaCl = 0.9 g per 100 mL = 9 g/L |
| % v/v | mL of solute per 100 mL of solution | 70% ethanol = 70 mL ethanol made up to 100 mL |
| % w/w | grams of solute per 100 g of solution | Concentrated acids on the bottle label (37% HCl) |
| Molarity (M) | moles of solute per litre of solution | 58.44 g NaCl in 1 L = 1 mol/L |
| Molality (m) | moles of solute per kilogram of solvent | Used for osmolality (mOsm/kg) |
| Normality (N) | gram-equivalents per litre of solution | 1 M H2SO4 = 2 N |
| mEq/L | milli-equivalents per litre = mmol/L × charge (valence) | Ca2+ 2.5 mmol/L = 5.0 mEq/L |
Worked examples
- How many grams of NaCl (MW 58.44) make 500 mL of 0.15 mol/L? 0.15 mol/L × 0.500 L × 58.44 g/mol = 4.38 g.
- Calcium 10 mg/dL in mmol/L and mEq/L (MW 40.08): mmol/L = mg/dL × 10 ÷ MW = 10 × 10 ÷ 40.08 = 2.5 mmol/L; × valence 2 = 5.0 mEq/L.
- 1 mol/L H2SO4 gives 2 H⁺ per molecule → 2 N. 1 mol/L HCl = 1 N. 1 mol/L H3PO4 (full neutralization) = 3 N.
Concentrated acids: specific gravity and purity
The label gives specific gravity (SG) (grams per mL) and purity (% w/w). Only the pure part counts.
- HCl, SG 1.19, 37%, MW 36.46: 1.19 × 1000 × 0.37 = 440 g/L ÷ 36.46 = about 12 mol/L.
- H2SO4, SG 1.84, 96%, MW 98.08: 1.84 × 1000 × 0.96 = 1766 g/L ÷ 98.08 = 18 mol/L = 36 N.
Hydrates
A hydrate carries water inside the crystal, so you must weigh more of it to get the same number of moles. Grams of hydrate = grams of anhydrous form × (MW hydrate ÷ MW anhydrous).
Example: a method needs 10 g anhydrous CuSO4 (MW 159.6) but only CuSO4·5H2O (MW 249.7) is available: 10 × 249.7 ÷ 159.6 = 15.6 g.
Percent solutions → molarity and normality, and mEq → grams
- 20% w/v NaOH (MW 40): 20 × 10 = 200 g/L ÷ 40 = 5 mol/L = 5 N (one OH⁻).
- Grams for a mEq solution: 100 mL of a 140 mEq/L Na⁺ standard made from NaCl (MW 58.44). Na⁺ has charge 1, so 140 mEq/L = 140 mmol/L. 140 mmol/L × 0.100 L = 14 mmol × 58.44 mg/mmol = 818 mg = 0.82 g NaCl.
- Gravimetric factor (part of a compound): you need 100 mg of Na⁺ but must weigh NaCl. Weigh 100 × (58.44 ÷ 22.99) = 254 mg NaCl. The compound weight is always MORE than the weight of the ion it carries.
Osmolality of a prepared solution and ionic strength
Osmolality counts particles, not molecules. A salt that splits in water gives more than one particle per molecule.
- 0.1 mol NaCl + 0.1 mol glucose in 1 kg water: (0.1 × 2) + (0.1 × 1) = 0.3 osmol/kg.
- 0.9% saline = 9 g/L ÷ 58.44 = 0.154 mol/L × 2 ≈ 308 mOsm/L if ideal; with φ 0.93 it is about 286 — close to plasma.
- 0.1 mol/L CaCl₂: Ca²⁺ 0.1 × 2² = 0.4; Cl⁻ 0.2 × 1² = 0.2; I = ½ × 0.6 = 0.3. For NaCl, I equals its molarity (0.1 mol/L → 0.1).
pH, pOH and buffers
- [H⁺] = 1 × 10⁻³ mol/L → pH 3. Each tenfold change in [H⁺] moves pH by 1 unit.
- 0.1 mol/L weak acid, 1% ionized: [H⁺] = 0.1 × 0.01 = 10⁻³ → pH 3.
- [OH⁻] = 1 × 10⁻⁴ → pOH 4 → pH 10. NaOH 0.001 mol/L → pOH 3 → pH 11 → 0.04 g NaOH per litre.
- Acetate buffer, pKa 4.76, salt : acid = 10 : 1 → pH = 4.76 + 1 = 5.76. Equal salt and acid → pH = pKa.
Other units: metric prefixes, temperature, weight, ppm, glassware
| Prefix | Factor | Prefix | Factor |
|---|---|---|---|
| kilo (k) | 10³ | micro (µ) | 10⁻⁶ |
| deci (d) | 10⁻¹ | nano (n) | 10⁻⁹ |
| centi (c) | 10⁻² | pico (p) | 10⁻¹² |
| milli (m) | 10⁻³ | femto (f) | 10⁻¹⁵ |
- Which is smallest — 1 ng, 500 pg or 0.001 mg? Change all to grams: 10⁻⁹, 5 × 10⁻¹⁰, 10⁻⁶ → 500 pg.
- 98.6 °F → (98.6 − 32) × 5/9 = 37 °C = 310 K. 154 lb ÷ 2.2 = 70 kg.
- Lead 0.05 ppm = 0.05 mg/L = 0.005 mg/dL = 5 µg/dL.
- A 50-mL flask with ±0.1% tolerance: 50 × 0.001 = ±0.05 mL (49.95–50.05 mL).
Radioactivity: half-life and units
- ¹²⁵I (half-life about 60 days) after 120 days: n = 2 → 100% × ¼ = 25% left. After 180 days: 12.5%.
- 7 half-lives leave (½)⁷ = 0.78% — less than 1%; 10 half-lives leave less than 0.1% (rule used for decay-in-storage waste).
Source: Tietz Textbook of Laboratory Medicine, 7th ed., Ch 15 Principles of Basic Techniques and Laboratory Safety (molarity, molality, normality, p. 199.e1); Ch 37 Electrolytes and Blood Gases (glucose ÷ 18, urea ÷ 2.8, p. 415.e10); Ch 44 Toxic Elements (conversion table incl. creatinine × 88.4, p. 455.e1); SUCCESS! Ch.12 Laboratory Calculations. · SUCCESS! Ch.12 Laboratory Calculations (book only: % to normality, mEq to grams, gravimetric factor) (gap check v-next) · Tietz 7th ed., Ch 37 Electrolytes and Blood Gases (osmotic coefficient, p. 415.e10); Ch 17 Electrochemistry and Chemical Sensors (ionic strength, p. 224.e8) (gap check v-next) · Tietz 7th ed., Ch 15 Principles of Basic Techniques and Laboratory Safety (pH definition, Henderson–Hasselbalch, buffer capacity ±1 unit of pKa, p. 199.e14); pH + pOH = 14 book only (SUCCESS! Ch.12) (gap check v-next) · Tietz 7th ed., Ch 15 Principles of Basic Techniques and Laboratory Safety (SI base units incl. kelvin, Table 15.1, p. 199.e1; metric prefixes, Table 15.3, p. 199.e2); °F, pounds, ppm and glassware tolerance book only (SUCCESS! Ch.12) (gap check v-next) · Tietz 7th ed., Ch 15 Principles of Basic Techniques and Laboratory Safety (radionuclide half-lives, Table 15.12, p. 199.e11; half-life, 7 and 10 half-lives, Bq and Ci, p. 199.e12) (gap check v-next)
2 · Dilutions
Simple idea: a dilution tells you how many parts of sample are in how many parts of the total mixture. To get back to the patient's real value, multiply the result by the dilution factor.
| Words | Meaning | Total parts |
|---|---|---|
| "1:5 dilution" (= 1/5) | 1 part sample in 5 parts total | 1 + 4 = 5 |
| "1:4 ratio" (sample : diluent) | 1 part sample to 4 parts diluent | 1 + 4 = 5 → also a 1/5 dilution |
Making a weaker solution from a stronger one: C1V1 = C2V2
The amount of solute does not change when you add diluent, so concentration × volume is the same before and after.
Example: make 500 mL of 0.1 mol/L from a 2 mol/L stock. V1 = C2V2 ÷ C1 = 0.1 × 500 ÷ 2 = 25 mL stock, then add diluent to a total of 500 mL (about 475 mL).
Serial dilutions
Each tube is a dilution of the tube before it. The total dilution is the product of each step.
- 1:2 → 1:5 → 1:10 gives a final dilution of 1/2 × 1/5 × 1/10 = 1:100.
- A two-fold series of a 1000 mg/dL stock: 500, 250, 125, 62.5 … mg/dL (stock ÷ 2ⁿ for tube n).
Correcting a patient result
Glucose is above the linear range. 0.2 mL serum + 0.8 mL saline (1:5) reads 160 mg/dL. Patient glucose = 160 × 5 = 800 mg/dL.
Titration and correcting a solution's strength
At the end point of an acid–base titration, equivalents of acid = equivalents of base, so the C1V1 rule works with normality.
- 20.0 mL of NaOH needs 25.0 mL of 0.100 N HCl: N = 0.100 × 25.0 ÷ 20.0 = 0.125 N.
- 1000 mL of acid titrates at 0.105 N but should be 0.100 N: final volume = 0.105 × 1000 ÷ 0.100 = 1050 mL → add 50 mL water. Use only the volume LEFT after the titration aliquot was removed.
- Units first: from a 5 mg/mL stock, make 100 mL of 25 mg/dL. 25 mg/dL = 0.25 mg/mL → V1 = 0.25 × 100 ÷ 5 = 5 mL.
Source: Tietz 7th ed., Ch 15 Principles of Basic Techniques and Laboratory Safety (dilution, serial dilution, dilution factor, p. 199.e14); SUCCESS! Ch.12 Laboratory Calculations; Harr §5.4 Calculations, Quality Control and Statistics. · Tietz 7th ed., Ch 15 Principles of Basic Techniques and Laboratory Safety (C1 × V1 = C2 × V2, p. 199.e14); titration and correction book only (SUCCESS! Ch.12) (gap check v-next)
3 · Standard curves and Beer's law calculations
Simple idea: absorbance (A) rises in a straight line with concentration (Beer's law), so one standard of known concentration lets you calculate the unknown.
Worked examples
- %T = 50 → A = 2 − log 50 = 2 − 1.699 = 0.301. %T = 10 → A = 1.0. %T = 100 → A = 0.
- A = 0.5 → %T = 10^(2 − 0.5) = 31.6%.
- One-point calculation: a 100 mg/dL standard reads A 0.40, the patient reads A 0.25 → Cu = 0.25 ÷ 0.40 × 100 = 62.5 mg/dL.
- Using molar absorptivity: NADH at 340 nm has ε = 6.22 × 10³ L·mol⁻¹·cm⁻¹. A = 0.311 in a 1-cm cuvet → c = A ÷ (ε × b) = 0.311 ÷ 6220 = 5.0 × 10⁻⁵ mol/L = 50 µmol/L.
Plotting and reading a standard curve
- Plot absorbance (y) against concentration (x) on ordinary graph paper → straight line through zero (after blanking).
- %T against concentration on ordinary paper gives a curve; on semilog paper (log of %T) it becomes a straight line.
- Linearity = the range where the line stays straight. Above it (stray light, too much colour, reagent exhausted) the line bends toward the x-axis.
- Interpolate (read between standards) — never extrapolate above the highest standard. Dilute the sample and repeat.
When does Beer's law hold?
- %T = I ÷ I₀ × 100 (I = light leaving the sample, I₀ = light entering it).
- Light must be (nearly) monochromatic: a narrow bandwidth gives higher absorbance and better linearity; a wide bandpass lets through light the analyte does not absorb.
- The solution must be dilute enough to stay in the linear range.
- Only the analyte should absorb: set 100%T (A = 0) with a reagent blank that contains everything except the analyte.
- The law fails if the analyte fluoresces or keeps reacting (its concentration changes) during the reading.
- Use at least two calibrators with each run; a calibration factor is valid only inside the linear part.
Source: Tietz 7th ed., Ch 16 Optical Techniques (Beer's law and spectrophotometry nomenclature, Table 16.2, p. 203; linearity, p. 208); SUCCESS! Ch.1 §I and Ch.12; Harr §5.1 and §5.4. · Tietz 7th ed., Ch 16 Optical Techniques (%T = I/I₀, Table 16.2, and calibrators, p. 203; reagent blank, p. 204; bandwidth and Beer's law agreement, p. 206); fluorescence/reaction book only (SUCCESS! Ch.12) (gap check v-next)
4 · Descriptive statistics
Simple idea: a list of results is described by its centre (mean, median, mode) and its spread (range, SD, CV).
Centre
| Measure | How | Data 4, 5, 5, 6, 7, 8, 14 |
|---|---|---|
| Mean | sum ÷ number of values | 49 ÷ 7 = 7 |
| Median | middle value after sorting (50th percentile) | 6 |
| Mode | most frequent value | 5 |
The single high value (14) pulls the mean up, but hardly moves the median. In a right (positive) skew: mode < median < mean. In a perfect Gaussian (bell) curve, mean = median = mode.
Spread
Worked example — five control results: 98, 100, 102, 99, 101 mg/dL. Mean = 100. Deviations −2, 0, +2, −1, +1 → squares 4, 0, 4, 1, 1 = 10. 10 ÷ (5 − 1) = 2.5 → SD = 1.58. CV = 1.58 ÷ 100 × 100 = 1.58%.
Confidence interval (CI) of a mean
The mean of a sample is only an estimate. The standard error (SE) = SD ÷ √n. The 95% CI ≈ mean ± 2 × SE (for 30 or more results).
Example: 36 results, mean 100, SD 6 → SE = 6 ÷ 6 = 1 → 95% CI ≈ 98 to 102. More results → smaller SE → narrower CI.
Precision vs accuracy
- Precision = how close repeated results are to each other (expressed as SD or CV). Random error.
- Accuracy (trueness) = how close results are to the true value (bias). Systematic error.
- CV lets you compare precision at different concentrations or between methods because it has no units. QC rules (Levey–Jennings, Westgard) are Module 19.
- Reference interval = the central 95% of results from healthy people (mean ± 2 SD only if the data are Gaussian; otherwise the 2.5th–97.5th percentiles).
z-score, combining SDs and the many-tests effect
- Mean 100, SD 5, result 110 → z = +2.
- Within-run SD 3 and between-day SD 4 → total SD = √(9 + 16) = 5, not 7.
- 10 tests → 1 − 0.95¹⁰ ≈ 40%; 20 tests → about 64% of healthy people get at least one "abnormal" flag.
Source: Tietz 7th ed., Ch 2 Statistical Methodologies in Laboratory Medicine (CV definition p. 12; median p. 13; mean, SD, CV equations and Gaussian 68.26/95.44/99.72% p. 14; standard error and 95% CI p. 15); Ch 9 Reference Intervals (central 95%, p. 167); SUCCESS! Ch.12 and Ch.13; Harr §5.4. · Tietz 7th ed., Ch 2 Statistical Methodologies in Laboratory Medicine (standard Gaussian variable z, p. 15; SD of a sum/difference, p. 42); Ch 9 Reference Intervals (1 − 0.95ᵐ, 10 tests ≈ 40%, p. 189) (gap check v-next)
5 · Sensitivity, specificity and predictive values
Simple idea: compare the test with the truth (a reference method or the final diagnosis) in a 2 × 2 table.
| Disease present | Disease absent | |
|---|---|---|
| Test positive | True positive (TP) | False positive (FP) |
| Test negative | False negative (FN) | True negative (TN) |
Worked example (1000 people, prevalence 10%)
100 have the disease: 90 test positive (TP), 10 negative (FN). 900 do not: 45 test positive (FP), 855 negative (TN).
- Sensitivity = 90 ÷ 100 = 90% · Specificity = 855 ÷ 900 = 95%
- PPV = 90 ÷ 135 = 66.7% · NPV = 855 ÷ 865 = 98.8% · Efficiency = 945 ÷ 1000 = 94.5%
Prevalence changes the predictive values
Use the SAME test in a population where only 1% have the disease (10 of 1000): TP = 9, FP = 5% of 990 ≈ 49.5. PPV = 9 ÷ 58.5 ≈ 15%. Sensitivity and specificity did not change, but most positives are now false.
Moving the cut-off
- Lower cut-off → more positives → sensitivity ↑, specificity ↓ (fewer missed cases, more false alarms) — good for screening.
- Higher cut-off → specificity ↑, sensitivity ↓ — good for confirming a diagnosis.
- The ROC curve plots sensitivity against (1 − specificity) at every cut-off; area 1.0 = perfect test, 0.5 = useless.
Likelihood ratios and the PPV formula
- Same test (sens 90%, spec 95%): LR+ = 0.90 ÷ 0.05 = 18; LR− = 0.10 ÷ 0.95 ≈ 0.11.
- Prevalence 10% → pre-test odds 0.1 ÷ 0.9 = 0.111 × 18 = 2.0 → probability 2 ÷ 3 = 66.7% — the same PPV as the 2 × 2 table.
- LR far above 1 → result makes disease more likely; LR near 1 → result adds little.
Source: Tietz 7th ed., Ch 2 Statistical Methodologies in Laboratory Medicine (diagnostic accuracy, sensitivity, specificity, ROC curve and predictive values/prevalence, pp. 44–47); Ch 14 Laboratory Stewardship and Test Utilization (low prevalence → poor PPV, p. 198.e3); Harr §5.4. · Tietz 7th ed., Ch 2 Statistical Methodologies in Laboratory Medicine (predictive value from prevalence, likelihood ratios and odds, p. 47) (gap check v-next)
6 · The required chemistry calculations
The ASCP chemistry guideline names these calculations. Learn each formula, the units and one worked example.
| Calculation | Formula | Worked example |
|---|---|---|
| % transferrin saturation | serum iron ÷ TIBC × 100 | Iron 60 µg/dL, TIBC 450 µg/dL → 13% (low → iron deficiency) |
| UIBC | TIBC − serum iron (TIBC = UIBC + iron) | 450 − 60 = 390 µg/dL |
| Indirect (unconjugated) bilirubin | total − direct | 3.2 − 0.4 = 2.8 mg/dL |
| LDL cholesterol (Friedewald) | TC − HDL − TG/5 (mg/dL); TG/2.2 in mmol/L | TC 220, HDL 50, TG 150 → 220 − 50 − 30 = 140 mg/dL |
| Non-HDL cholesterol | TC − HDL | 220 − 50 = 170 mg/dL |
| Globulin and A/G ratio | globulin = total protein − albumin; A/G = albumin ÷ globulin | TP 7.0, albumin 4.2 → globulin 2.8 g/dL; A/G = 1.5 |
| Timed (24-h) urine output | concentration × volume (same volume units!) | Protein 45 mg/dL × 18 dL (1800 mL) = 810 mg/24 h |
| Creatinine clearance | (U × V) ÷ P, V in mL/min; × 1.73 ÷ BSA | U 120 mg/dL, P 1.2 mg/dL, 1440 mL/24 h (= 1.0 mL/min) → 100 mL/min; BSA 1.50 m² → 100 × 1.73 ÷ 1.50 = 115 mL/min/1.73 m² |
| Calculated osmolality | 2 × Na + glucose/18 + BUN/2.8 (mg/dL) | Na 140, glucose 90, BUN 14 → 280 + 5 + 5 = 290 mOsm/kg |
| Osmolal gap | measured − calculated osmolality | Measured 320 − calculated 290 = 30 (normal about 10 or less) → think toxic alcohol |
| Anion gap | Na − (Cl + HCO3) | 140 − (104 + 24) = 12 mmol/L (if K is added, the reference interval is higher) |
| Enzyme activity (U/L) | ΔA/min × total volume × 10⁶ ÷ (ε × b × sample volume) | ΔA/min 0.05, TV 1.0 mL, SV 0.05 mL, NADH ε 6220 → 161 U/L |
Source: Tietz 7th ed., Ch 40 Iron Metabolism (TIBC = UIBC + iron, transferrin saturation, pp. 418.e9–418.e13); Ch 51 Liver Disease (indirect = total − direct bilirubin, p. 709); Ch 36 Lipids and Lipoproteins (non-HDL-C = TC − HDL-C p. 375; VLDL-C as TG/5 p. 394; Friedewald limit TG > 400 mg/dL p. 403; newer equations p. 405); Ch 34 Kidney Function Tests (BSA 1.73 m² adjustment p. 352.e28; creatinine clearance p. 352.e33); Ch 37 Electrolytes and Blood Gases (calculated osmolality, p. 415.e10); Ch 43 Clinical Toxicology (anion gap p. 454.e5; osmolal gap p. 454.e6); Ch 16 Optical Techniques (molar absorptivity); SUCCESS! Ch.1 (globulins = TP − albumin p. 23; Friedewald p. 39; % saturation p. 63) and Ch.12. · Tietz 7th ed., Ch 25 Enzyme and Rate Analysis (international unit, p. 300.e6); total volume incl. sample book only (SUCCESS! Ch.12) (gap check v-next)
7 · Exam traps — the commonest calculation errors
| Trap | Correct approach |
|---|---|
| "1 + 9" called a 1:9 dilution | It is 1:10 (sample ÷ total). DF = 10. |
| Forgetting to multiply a diluted result | Result on dilution × DF = patient value. |
| mg/dL ↔ mmol/L off by 10× | mmol/L = mg/dL × 10 ÷ MW. |
| Molarity vs molality | Per litre of solution vs per kg of solvent. |
| Normality of H2SO4 | 2 × molarity (two H⁺). |
| Concentrated acid without purity | SG × 1000 × purity ÷ MW. |
| Hydrate weighed like anhydrous | Multiply by MW hydrate ÷ MW anhydrous (need MORE). |
| %T treated as proportional to concentration | Only absorbance is; A = 2 − log %T. |
| Extrapolating past the top standard | Dilute and rerun. |
| SD divided by n | Divide by n − 1 for a sample. |
| PPV confused with sensitivity | PPV = TP ÷ all positives; depends on prevalence. |
| Clearance with 24-h volume in mL | Use mL/min (volume ÷ 1440). |
| Friedewald used with TG 600 mg/dL | Not valid above 400 mg/dL. |
| Anion gap with K⁺ added silently | Check whether the formula includes K⁺ (gap about 4 higher). |
Summary of Study Sections 1–6 (Tietz 7th ed., Ch 2, 15, 16, 34, 36, 37, 40, 43, 51; SUCCESS! Ch.12; Harr §5.4).
⚡ Last-Minute Review — Laboratory Mathematics & Statistics
1. Concentrations
- % w/v = g per 100 mL · M = mol per L of solution · m (molal) = mol per kg of solvent · N = M × n (H⁺/OH⁻/charge).
- Grams needed = M × L × MW. mmol/L = mg/dL × 10 ÷ MW; mEq/L = mmol/L × valence.
- Glucose ÷ 18 · BUN ÷ 2.8 · creatinine × 88.4 (µmol/L) · calcium ÷ 4.
- Concentrated acid: SG × 1000 × purity ÷ MW (HCl 37% ≈ 12 M; H2SO4 96% ≈ 18 M = 36 N).
- Hydrate: grams × MW hydrate ÷ MW anhydrous (weigh MORE).
2. Dilutions
- Dilution = sample ÷ total (1 + 9 = 1:10). DF = total ÷ sample. Patient result = diluted result × DF.
- C1V1 = C2V2. Serial dilutions: multiply the steps (1:2 × 1:5 × 1:10 = 1:100).
3. Beer's law
- A = abc · A = 2 − log %T (100% → 0; 10% → 1; 1% → 2) · Cu = Au ÷ As × Cs.
- c = A ÷ (ε × b); NADH ε = 6.22 × 10³ at 340 nm. Interpolate, never extrapolate — dilute.
4. Statistics
- Mean = sum ÷ n · median = middle · mode = most frequent. Right skew: mode < median < mean.
- SD = √[Σ(x − mean)² ÷ (n − 1)] · variance = SD² · CV% = SD ÷ mean × 100.
- Gaussian: ±1 SD 68% · ±2 SD 95% (±1.96) · ±3 SD 99.7%. SE = SD ÷ √n; 95% CI ≈ mean ± 2 SE.
- Precision = repeatability (random error, SD/CV); accuracy = closeness to truth (bias). Reference interval = central 95%.
5. Test performance
- Sens = TP ÷ (TP + FN) · Spec = TN ÷ (TN + FP) · PPV = TP ÷ (TP + FP) · NPV = TN ÷ (TN + FN) · Efficiency = (TP + TN) ÷ all.
- Prevalence ↓ → PPV ↓, NPV ↑. Lower cut-off → sensitivity ↑, specificity ↓. SnNout · SpPin.
6. Required calculations
- % saturation = iron ÷ TIBC × 100 · UIBC = TIBC − iron · indirect bilirubin = total − direct.
- LDL = TC − HDL − TG/5 (not valid if TG > 400 mg/dL) · non-HDL = TC − HDL · globulin = TP − albumin; A/G = alb ÷ glob.
- 24-h output = conc × volume (mg/dL × dL). CrCl = U × V ÷ P (V in mL/min) × 1.73 ÷ BSA.
- Osm = 2Na + glucose/18 + BUN/2.8; osmolal gap = measured − calculated (> about 10 → toxic alcohol?).
- AG = Na − (Cl + HCO3) ≈ 12. Enzyme U/L = ΔA/min × TV × 10⁶ ÷ (ε × b × SV).