Press ✓ Mark section complete at the end of each section after you study it. Opening the page does not mark anything. Tap a chip to jump. Labels: 🔥 very high-yield · 📌 must memorize · ⚠️ exam trap · 🧠 memory trick · 🔬 lab connection · 💡 understand this.
1 · Start here — the laboratory, food service and pharmacy for the infection preventionist
Simple idea: three support departments can either protect patients or spread infection to many of them at the same time. The laboratory finds the germs and protects its own workers. Food and nutrition services (FNS) feed every patient, so one mistake can make a whole ward ill. The pharmacy prepares and stores medicines that go straight into the blood, so one contaminated bag or vial can reach dozens of patients. The infection preventionist (IP) works with all three as partners.
Every question in this topic is one of four jobs:
- Partner: use what the department gives you (culture results, antibiogram, product information, temperature logs) and tell it what you need.
- Protect the worker: biosafety levels, biological safety cabinets (BSCs), safe lab practice, safe shipping and waste in the laboratory.
- Protect the product: safe food flow and temperatures in the kitchen; safe vials, injections and sterile compounding in the pharmacy.
- Respond to a cluster: when many patients share one food, one drug or one lot, save the evidence, report, investigate with public health, then fix the failed step.
| # | Study section | APIC chapters | CIC domain(s) |
|---|---|---|---|
| 1 | Start here: map | 110, 111, 112 | EC, MC |
| 2 | The laboratory as the IP's partner | 110 | SEI, MC, EC |
| 3 | Biosafety levels, risk assessment, BSCs, LRN | 110 | EC, EOH |
| 4 | Lab-acquired infection, shipping and lab waste | 110 | EOH, EC, CSDA |
| 5 | Foodborne illness in healthcare | 111 | SEI, IDP, EC |
| 6 | Safe food flow and temperatures | 111 | EC |
| 7 | Food staff and kitchen hygiene | 111 | EC, EOH |
| 8 | Pharmacy and infection prevention | 112 | EC, SEI, MC |
| 9 | Safe injection, vials and hang times | 112 | PCT, EC |
| 10 | Sterile compounding (USP <797> / <800>) | 112 | EC, PCT |
| 11 | Decisions, numbers and traps | 110, 111, 112 | all |
Sources: APIC Text, Ch.110 Laboratory Services — 'Key Concepts', 'Infection Prevention Team Member'; Ch.111 Nutrition Services — 'Key Concepts', 'Background'; Ch.112 Pharmacy Services — 'Key Concepts', 'Background' · CDC/NIH: BMBL 6th ed. (2020) · FDA Food Code (2022) · USP General Chapter <797> (official 1 Nov 2023).
2 · The laboratory as the IP's partner — what the lab gives infection prevention, and who regulates the lab
Simple idea: the infection preventionist (IP) cannot find most infections without the laboratory. The microbiology laboratory finds and names the germ, tests which antibiotics work, and keeps the data the IP uses for surveillance. So the laboratory is a team member of the infection prevention program, not only a service. A laboratory leader should sit on the infection prevention and control committee, and the IP should visit the laboratory often.
What the laboratory gives the IP
| Laboratory contribution | Why the IP needs it |
|---|---|
| Teaching basic microbiology and explaining culture results | A positive culture is not always an infection. The laboratory helps separate infection, colonization and contamination (for example one bottle of coagulase-negative staphylococci out of four). |
| Explaining methods: strengths, limits, cost | The IP must know what a test can and cannot detect before using it for case finding or screening. |
| Advance notice of method, reagent or instrument changes | A new, more sensitive test can raise infection rates without any real change in patients (see below). |
| Rapid notification of alert organisms and clusters | Calls for organisms such as carbapenem-resistant Enterobacterales, Candida auris, methicillin-resistant Staphylococcus aureus (MRSA) in a new unit, or several similar isolates in a short time, so isolation starts early. |
| The antibiogram (at least yearly) | A summary of the percentage of isolates of each organism that are susceptible to each drug. It shows resistance trends and supports antimicrobial stewardship and empiric therapy choices. |
| Saving isolates | When a cluster is suspected, saved isolates can be sent for strain typing (for example whole genome sequencing) to show whether cases are related. |
| Help in outbreak investigation | Planning which specimens to collect (patients, staff, environment) and which tests answer the question. Environmental cultures are done only with a clear purpose. |
| Specimen quality control and rejection rules | Poor specimens give misleading results: a sputum full of squamous cells, a leaking container, an unlabeled tube, a formed stool sent for Clostridioides difficile testing. |
| Reportable disease results | Laboratories also have legal duties to report certain results to public health; the IP coordinates so that reporting is complete and on time. |
Pseudo-outbreaks and contamination
A pseudo-outbreak is a rise in positive results without a real rise in disease. Causes include a contaminated reagent, a contaminated bronchoscope or specimen container, a laboratory cross-contamination event, or a new test. Clues: positive cultures but patients are not ill, many isolates of an unusual organism, and the cases link to one laboratory step or device. The laboratory and the IP investigate together.
Working together day to day
- Regular meetings and rounds in the laboratory: review new isolates, unusual resistance and pending results.
- An agreed alert organism list and a call-back process (who calls whom, how fast, also at night and on weekends).
- Written rules for how long isolates are kept and for saving isolates on request.
- When testing is sent out to a regional or reference laboratory, the contract should still give the IP fast results, alert calls and a microbiology contact for the committee.
Who regulates and accredits the laboratory
| Body | Role |
|---|---|
| Centers for Medicare & Medicaid Services (CMS) | Runs the Clinical Laboratory Improvement Amendments (CLIA) program: all testing on human specimens for diagnosis, prevention or treatment (research testing is outside CLIA). Issues certificates, surveys and enforces. |
| Food and Drug Administration (FDA) | Places each test in a complexity group (waived, moderate, high). |
| Centers for Disease Control and Prevention (CDC) | Technical standards, guidelines and quality studies for CLIA; biosafety guidance (with the National Institutes of Health). |
| Accreditation organizations with CLIA deeming authority | Current CMS list: AABB, American Association for Laboratory Accreditation (A2LA), Accreditation Commission for Health Care (ACHC), American Society for Histocompatibility and Immunogenetics (ASHI), COLA, College of American Pathologists (CAP), The Joint Commission (TJC). New York and Washington have state programs exempt from CLIA. |
| Clinical and Laboratory Standards Institute (CLSI) | Writes consensus standards (for example worker protection, waste, venipuncture). Not a regulator. |
| Occupational Safety and Health Administration (OSHA) | Worker safety law, including the Bloodborne Pathogens Standard. |
- Non-waived laboratories are surveyed every 2 years — by CMS or its state agency (Certificate of Compliance) or by an approved accreditor (Certificate of Accreditation). Waived-testing sites are not routinely surveyed. Older sources (e.g., APIC Text 2014) describe yearly state CLIA surveys.
- Most hospital laboratories are accredited by CAP, with peer inspection every 2 years and a self-assessment checklist. CAP grades items by phase: Phase I items should be corrected; Phase II items are serious and must be corrected before accreditation.
How the exam asks it
- "C. difficile rates jumped 40% the month the lab started PCR. FIRST step?" → review the method change with the laboratory before declaring an outbreak.
- "Three patients on one ward grow the same resistant organism. Best laboratory help?" → save the isolates and request strain typing.
- "What does the antibiogram show?" → percent of isolates susceptible to each drug, by organism, usually for one year.
- "Which agency runs CLIA?" → CMS (not FDA, not CAP).
Sources: APIC Text, Ch.110 Laboratory Services — 'Infection Prevention Team Member', 'Accreditation', 'Future Trends' · CMS: Clinical Laboratory Improvement Amendments (CLIA) brochure (MLN) · CMS: List of CLIA-approved accreditation organizations (August 2025).
3 · Biosafety levels, risk assessment, biological safety cabinets and the Laboratory Response Network
Simple idea: the more dangerous the germ and the more easily it spreads through the air, the more layers of protection the laboratory needs. The United States guide is Biosafety in Microbiological and Biomedical Laboratories (BMBL), written by CDC and the National Institutes of Health (NIH); the current edition is the 6th edition (2020). It describes four biosafety levels (BSL-1 to BSL-4), plus four animal biosafety levels for work with infected animals.
Three layers of protection
- Work practices — safe technique and training (the most important layer).
- Primary barriers — safety equipment around the work: biological safety cabinets, sealed centrifuge cups, personal protective equipment (PPE).
- Secondary barriers — the building: doors, sinks, air flow, surfaces that can be cleaned.
The four biosafety levels
| Level | Agents (examples) | Key practices and facility |
|---|---|---|
| BSL-1 | Well-known agents that do not cause disease in healthy adults (for example Bacillus subtilis) | Open bench, standard practices, hand washing sink; teaching labs |
| BSL-2 | Moderate hazard; spread by needlestick, mucous membrane or ingestion: hepatitis B virus, HIV, Salmonella, Toxoplasma. All human blood, body fluids and tissues of unknown status | Limited access when work is going on, biohazard sign, self-closing doors, sink near exit, eyewash; BSC for splash or aerosol work; care with sharps. Most hospital clinical laboratories |
| BSL-3 | Serious or lethal disease by inhalation: Mycobacterium tuberculosis cultures, Coxiella burnetii, St. Louis encephalitis virus | All open work in a BSC; entry through two self-closing doors (anteroom); inward directional airflow; exhaust air not recirculated to other areas; sealed surfaces; waste made noninfectious |
| BSL-4 | Dangerous or exotic agents with high aerosol risk and often no treatment or vaccine: Ebola, Marburg | Class III cabinet, or Class II with a one-piece positive-pressure suit; separate building or isolated zone; HEPA exhaust; all material decontaminated before leaving. Rare in hospitals |
Biological risk assessment
Each laboratory does a risk assessment of its agents and its procedures, repeats it regularly (APIC 2014: yearly) and whenever a new risk appears. Two big inputs: the agent hazard (how infectious, how severe, is there a vaccine or treatment) and the procedure hazard (volume and concentration, aerosol-making steps, sharps, staff skill). CDC teaches the process as: identify hazards → evaluate risk (likelihood × severity) → put mitigation in place → check that the controls work. Staff differ in susceptibility (pregnancy, immune suppression), so occupational health is involved. The IP and the safety committee review the result.
Biosecurity and select agents
Biosafety keeps people safe from germs; biosecurity keeps germs safe from people (loss, theft, misuse). Select agents and toxins are agents that could severely threaten public health, regulated by CDC and the Animal and Plant Health Inspection Service (APHIS) in the Federal Select Agent Program. A clinical laboratory that is not registered but identifies a select agent in a patient specimen must:
- report immediately for the highest-concern agents (for example Bacillus anthracis, Yersinia pestis, Francisella tularensis, botulinum toxin, Ebola and Marburg viruses, variola, Burkholderia mallei/pseudomallei);
- send APHIS/CDC Form 4 within 7 calendar days of identification, including what happened to the isolate (destroyed by autoclave or transferred to a registered laboratory);
- work with the local or state public health laboratory.
The Laboratory Response Network (LRN)
CDC set up the LRN in 1999 to respond to biological and chemical terrorism and other public health emergencies. The biological network has three levels:
| Level | Who | Job |
|---|---|---|
| Sentinel | Hospital and commercial clinical laboratories (thousands) | Front line. Recognize a suspicious isolate, rule out or refer, keep chain of custody, notify |
| Reference | About 120 state and local public health, military, veterinary, food and agriculture laboratories | Confirm the agent with standard LRN tests so local authorities can act fast |
| National | CDC and other federal laboratories | Strain characterization, forensics, the most dangerous agents |
Biological safety cabinets (BSCs)
A BSC uses high-efficiency particulate air (HEPA) filters and controlled airflow to keep aerosols away from the worker and the room. It is different from a chemical fume hood (protects the worker from vapors, no HEPA filter) and a laminar-flow clean bench (blows clean air toward the worker — protects only the product; never use it for infectious material).
| Cabinet | Protects | Key facts |
|---|---|---|
| Class I | Worker + environment (not the product) | Room air pulled in at the front (≥ 75 ft/min), HEPA-filtered exhaust; used for example to enclose equipment |
| Class II | Worker + environment + product | Inflow at front, HEPA-filtered downflow over the work and HEPA exhaust. Current types: A1 (≥ 75 ft/min inflow), A2, B1, B2, C1 (≥ 100 ft/min). Type B cabinets are hard-ducted; B2 exhausts all air. The usual clinical laboratory cabinet |
| Class III | Highest protection | Gas-tight box under negative pressure, work through attached gloves, exhaust through two HEPA filters (or HEPA + incineration); for BSL-4 agents |
- Certify at installation, after moving or repair, and at least every year.
- Place away from doors, walkways and air vents; do not use open flames inside; ultraviolet lamps are not a substitute for surface disinfection; disinfect the work surface after each use.
Older sources (e.g., APIC Text 2014) list Class II types as IIA, IIB1, IIB2 and IIB3; the current types are A1, A2, B1, B2 and C1.
Centrifuges and aerosols
Aerosols come from pipetting, mixing, vortexing, opening tubes, pouring off supernatant and from centrifuging itself. The worst event is a tube breaking during a spin. Prevent it with balanced loads, capped tubes, sealed safety cups or rotors (loaded and opened in the BSC), and waiting before opening the lid after a suspected break.
How the exam asks it
- "Which BSL for routine processing of blood specimens?" → BSL-2. "For M. tuberculosis culture work?" → BSL-3.
- "Which cabinet protects worker, environment and specimen?" → Class II.
- "Sentinel lab suspects F. tularensis. BEST action?" → stop work-up, use a BSC, refer to the LRN reference laboratory and notify.
Sources: APIC Text, Ch.110 Laboratory Services — 'Biosafety Levels', 'Biological Risk Assessment', 'Laboratory Biosecurity', 'Laboratory Response Network', 'Biological Safety Cabinets', 'Centrifuges' · CDC/NIH: Biosafety in Microbiological and Biomedical Laboratories, 6th ed. (2020), Section IV and Appendix A · CDC: Biological Risk Assessment Process (Safe Labs) · CDC: Laboratory Response Network for Biological Threats (LRN-B) · Federal Select Agent Program: APHIS/CDC Form 4.
4 · Laboratory-acquired infections, worker protection, shipping and laboratory waste
Simple idea: laboratory workers handle concentrated germs every day. Most laboratory-acquired infections (LAIs) have no clear exposure event, or come from an error, accident or careless handling. Classic LAIs include brucellosis, tuberculosis, typhoid, shigellosis, meningococcal disease and hepatitis. Prevention = Standard Precautions + good microbiological technique + engineering controls + training + occupational health follow-up.
Standard microbiological practices (BSL-2 laboratory)
- No mouth pipetting — use mechanical pipettors.
- No eating, drinking, smoking, applying cosmetics or handling contact lenses; no food stored in laboratory refrigerators.
- Wash hands after handling specimens, after removing gloves and before leaving the laboratory.
- Laboratory coat worn only in the laboratory and laundered by the facility (not taken home); gloves changed when soiled or torn and never washed or reused; eye and face protection for splash risk outside a BSC.
- Sharps: no recapping, bending or breaking of needles; puncture-resistant containers close to use; broken glass picked up with tongs or brush and pan, never with hands; replace glass with plastic when possible.
- Disinfect work surfaces after work and after every spill; decontaminate equipment before repair or removal.
- Biohazard sign at the entrance (biosafety level, responsible person, contact number, entry rules); a laboratory biosafety manual; training at hire and yearly and when procedures change.
Phlebotomy
- OSHA's Bloodborne Pathogens Standard requires gloves for venipuncture; add face protection or a gown when splashes are likely (for example arterial puncture, combative patient).
- Use safety-engineered needles. Blood tube holders are single-use: discard holder and needle together as one unit into the sharps container (OSHA).
- Patient protection: hand hygiene, single-patient or disposable tourniquets, skin antisepsis (alcohol for routine draws; for blood cultures a stronger antiseptic such as chlorhexidine-alcohol or an iodine preparation, allowed to dry, to reduce contamination).
Spills and exposures
- Spill: warn others and leave if an aerosol may have formed (wait for it to settle per policy) → PPE → cover with absorbent → apply an appropriate disinfectant (for example fresh bleach dilution) for the contact time → pick up glass with tools → discard as biohazard → report.
- Exposure (needlestick, splash, aerosol): first aid at once (wash skin with soap and water; flush eyes or mucous membranes with water), report immediately to the supervisor and occupational health, get medical evaluation and post-exposure care. Record the agent, route, time and place, PPE worn, first aid given, relevant medical history and witnesses.
- Post-exposure serology: one single result is hard to read. Paired sera (baseline and later) showing seroconversion or a fourfold titer rise support recent infection. Some research laboratories store a baseline serum before work starts.
- Think "laboratory exposure" when a laboratory worker has an unexplained febrile illness (for example brucellosis weeks after a plate was sniffed or handled on the open bench).
Occupational health for laboratory staff
Preplacement evaluation based on the job's hazards (history, immunizations, allergies, medicines — a full physical is rarely needed), vaccines for agents handled (hepatitis B vaccine offered under OSHA), medical clearance for respirators, and an easy, non-punitive way to report symptoms. Routine periodic examinations are generally not needed.
Transporting and shipping specimens
The U.S. Department of Transportation (DOT) Pipeline and Hazardous Materials Safety Administration (PHMSA) rules (and International Air Transport Association, IATA, rules for air) apply even to courier and car transport off-site.
| Class | Meaning | Marking | Examples |
|---|---|---|---|
| Category A | Can cause permanent disability or life-threatening or fatal disease in healthy people or animals when exposure occurs | UN2814 (affects humans) or UN2900 (animals only); infectious substance label; shipper's declaration | Ebola virus specimens; cultures of M. tuberculosis, B. anthracis, Brucella |
| Category B | Infectious, but does not meet Category A | UN3373 "Biological substance, Category B" | Most routine diagnostic specimens, including a sputum for TB testing |
| Exempt specimen | Low chance that a pathogen is present | "Exempt human specimen" | Blood for cholesterol or drug-level tests |
| Regulated medical waste | Waste from diagnosis, treatment or research | UN3291 | Shipped laboratory biohazard waste |
Triple packaging is the core of all shipping: (1) a leakproof primary container, (2) enough absorbent for all the liquid plus a leakproof secondary container, (3) a rigid outer package. The list of contents goes between the secondary and outer layers. For air transport of liquids, the primary or secondary container must withstand a pressure difference of 95 kPa. Category B by air: primary ≤ 1 L, outer package ≤ 4 L. Staff who pack hazardous materials need DOT training (refresher at least every 3 years; IATA every 2 years).
Laboratory waste and the autoclave
- The laboratory makes much of the facility's infectious waste: cultures and stocks, pathology tissue, blood and blood products, sharps, waste from patients with highly communicable disease.
- Segregate at the point of use; sharps into puncture-resistant containers; keep handling and transport short.
- Cultures and stocks are decontaminated before they leave the facility (usually steam autoclave) or are incinerated by a licensed vendor — never put directly into the sewer or landfill.
- Liquid blood and body fluids may be poured carefully into the sanitary sewer if local rules allow: wear face protection and a fluid-resistant apron if splashing is possible, pour gently without running water, then flush with plenty of water. This sink is not used for hand washing.
- Waste with select agents is autoclaved before leaving the laboratory.
- Waste storage: brief, labeled with the biohazard symbol, access restricted, cleaned each time it is emptied.
Autoclave verification: waste loads are dense, so cycles are longer than for clean instruments (APIC 2014: often 60–90 minutes or more at about 121 °C, per the manufacturer). Load correctly (do not overpack, open or loosen bags so steam can enter) and check function with a biological indicator of Geobacillus stearothermophilus spores (formerly Bacillus stearothermophilus) at a set interval — APIC 2014 says at least weekly; BMBL 6th ed. asks for validation and regular verification ⚑ Not verified (exact current interval not stated in the pages checked). A failed indicator → remove the autoclave from use, reprocess the waste, repair and retest.
How the exam asks it
- "Most important rule to prevent ingestion of agents?" → no mouth pipetting (and no eating or drinking).
- "A culture of M. tuberculosis is sent to a reference laboratory. How is it classified?" → Category A, UN2814.
- "Laboratory tech has a splash to the eye. FIRST action?" → flush the eye with water, then report and get evaluation.
- "Autoclave biological indicator is positive. NEXT step?" → take the autoclave out of service, reprocess the loads since the last good test, repair, retest.
Sources: APIC Text, Ch.110 Laboratory Services — 'Background', 'Work Practices, Safety Equipment, and Facility Safeguards', 'Phlebotomy', 'Transporting Biohazardous Materials', 'Infectious Waste Management', 'Occupational Prevention and Exposures' · CDC/NIH: Biosafety in Microbiological and Biomedical Laboratories, 6th ed. (2020) · DOT/PHMSA: Transporting Infectious Substances Safely (2022) · OSHA: Bloodborne Pathogens Standard, 29 CFR 1910.1030; OSHA Safety and Health Information Bulletin on blood tube holders (2003).
5 · Foodborne illness in healthcare — who is at risk, which germs, and what to do first
Simple idea: a hospital kitchen feeds the people who are least able to fight a gut infection. A small mistake in a kitchen — food left warm too long, an ill cook, a dirty slicer — can make many patients sick at the same time. The food and nutrition services (FNS) department prevents this every day, and the infection preventionist (IP) helps it watch, investigate and fix problems together with public health.
Who is at highest risk?
The U.S. Food and Drug Administration (FDA) Food Code calls these people a highly susceptible population (HSP): people who are more likely than others to get foodborne illness because they are immunocompromised, very young (preschool age) or older adults, and who get their food in a facility that gives custodial care, health care or assisted living. Every hospital and nursing home serves an HSP. In practice think of: newborns and infants, older residents, pregnant women (risk of Listeria), transplant and chemotherapy patients, people with low stomach acid, and tube-fed patients.
How big is the problem?
The Centers for Disease Control and Prevention (CDC) published new burden estimates in 2025 for seven major pathogens (about 2019 data): roughly 9.9 million illnesses, 53,300 hospitalizations and 931 deaths per year in the United States. Norovirus causes the most illnesses and the most hospitalizations; Salmonella causes the most deaths; Listeria causes few illnesses but almost every case is hospitalized. Older sources (e.g., APIC Text 2014) give the 2011 CDC figures — about 48 million illnesses (1 in 6 Americans), 128,000 hospitalizations and 3,000 deaths from all foodborne agents — and call Salmonella the leading cause.
Infection, intoxication, toxin-mediated infection
The exam likes this difference because it explains the timing and why cooking may not help.
| Type | What happens | Examples | Typical foods / clues |
|---|---|---|---|
| Infection | Live germs are eaten and multiply in the gut or invade the body; onset usually a day or more | Salmonella, Campylobacter, Shiga toxin-producing E. coli (STEC), Shigella, Listeria, Vibrio | Poultry, eggs, undercooked ground beef, raw milk, soft cheese, deli meat, raw oysters, produce |
| Intoxication | The germ grows in the food and makes a toxin before it is eaten; onset fast (hours), vomiting common; reheating may not destroy the toxin | Staphylococcus aureus, Bacillus cereus (vomiting type), Clostridium botulinum | Hand-made salads, ham, cream desserts (Staph from food handlers' skin); cooked rice held warm (B. cereus); reduced-oxygen packaged foods (botulism) |
| Toxin-mediated infection | Germs are eaten and release toxin in the gut | Clostridium perfringens | Large batches of meat, stews and gravy cooled slowly — a classic "institutional" outbreak |
| Viruses | Do not grow in food; food is only the vehicle, usually through an infected worker's hands | Norovirus, hepatitis A virus | Ready-to-eat food, salads, ice, raw shellfish from polluted water |
| Parasites | Do not grow in food; killed by proper cooking (or freezing for some fish) | Toxoplasma, Cyclospora, Cryptosporidium, Trichinella, Anisakis | Undercooked pork or game, raw fish, imported produce, contaminated water |
| Natural toxins | Chemical poisons in the food itself; cooking does not help | Scombroid and ciguatera (fish), shellfish toxins, poisonous mushrooms | Fish held warm (scombroid), reef fish (ciguatera) |
Why do kitchens fail?
The Food Code names five main risk factors for foodborne illness. Learn them as one list, because almost every scenario fits one of them:
- Food from unsafe sources (home-canned food, unapproved suppliers, recalled product).
- Inadequate cooking (end temperature not reached or not held).
- Improper holding temperature or time (slow cooling, warm cold-holding, cold hot-holding) — the practice most often linked to outbreaks.
- Contaminated equipment and cross-contamination (raw meat juices on a ready-to-eat surface, a dirty slicer).
- Poor personal hygiene — especially poor hand washing, bare-hand contact with ready-to-eat food and ill workers who keep working.
Detecting a cluster
CDC defines a foodborne disease outbreak as two or more people who get a similar illness after eating or drinking a common food. In a hospital, suspect it when several patients, staff or visitors who ate food prepared in the facility develop similar gastrointestinal illness close in time — for example vomiting on two units the morning after the same lunch, or staff who ate in the cafeteria falling ill. Surveillance clues come from the laboratory (several Salmonella isolates; whole-genome sequencing links), from employee health (staff calling in sick with diarrhea) and from nurses on the units.
The FIRST actions in a suspected foodborne outbreak
FNS should save leftover suspected food for a qualified laboratory, write down how the food was prepared and held, give the IP a list of foods served in the suspected period, report ill staff and patients, and carry out the control measures. Public health reporting follows state and local law; in many states it is mandatory, and the health department usually leads food testing, because most hospital laboratories do not culture food.
The investigation in order
- Confirm that there really is an outbreak (not a pseudo-outbreak, not the usual baseline).
- Write a case definition (person, place, time, symptoms).
- Confirm the diagnosis with clinical and laboratory tests (stool culture or molecular panel; norovirus testing).
- Notify public health.
- Look for more cases.
- Describe cases by time (epidemic curve) and place; interview ill and well people about everything eaten in the days before onset (at least 3 days); calculate food-specific attack rates.
- Test the implicated food if it is available (usually by the public health laboratory).
- Form a hypothesis about the food and the failure.
- Put control measures in place (often already started on day 1).
- Write and share a final report: features, mode of transmission, control measures.
Surveys, recalls and emergencies
- Surveyors: the local (county or city) health department, state licensing agencies, the Centers for Medicare & Medicaid Services (CMS), The Joint Commission (TJC) and the Occupational Safety and Health Administration (OSHA) can all inspect the kitchen. Inspections may be unannounced. Most states base their food rules on the FDA Food Code. FNS keeps the standards on hand, trains staff on them and runs mock surveys.
- Recalls: the U.S. Department of Agriculture (USDA) Food Safety and Inspection Service announces recalls of meat, poultry and egg products; FDA handles most other foods; suppliers may also call. Pull the product, separate and mark it "do not use", then return or discard it as the recall says. Keeping lot numbers makes this possible.
- Imminent health hazard: the Food Code says operations must stop and the regulatory authority must be told after a fire, flood, long loss of power or water, sewage backup, misuse of toxic chemicals, or the start of an apparent foodborne outbreak — unless an approved emergency plan allows safe continued service.
- Emergency planning: FNS plans food and potable water for patients and staff (APIC cites a common state requirement of about a 72-hour supply), disposable dishes, refrigerated trucks, safe preparation of infant and enteral formulas, and alcohol hand rub when water fails.
How the exam asks it
- "Several patients vomit 2–4 hours after lunch. FIRST action?" → keep the leftover suspected food, then report and start the investigation with public health.
- "BEST way to find the vehicle?" → interview ill and well people and compare food-specific attack rates.
- "Should the kitchen culture all food workers every month?" → No; test ill workers when indicated.
- "Who must be notified?" → the local or state health department, as required by law, plus FNS leadership, employee health and the infection prevention committee.
Sources: APIC Text, Ch.111 Nutrition Services — 'Infection Risk', 'Hazardous Agents', 'Monitoring for Contamination', 'Addressing a Foodborne Outbreak', 'Investigating a Foodborne Outbreak', 'Surveying Agencies for Healthcare FNS', 'Emergency Management Preparedness', 'Food Safety and Recall' · FDA: Food Code 2022 (definition of highly susceptible population; §3-801.11; §8-404.11; Annex 4 risk factors) and Summary of Changes in the 2026 FDA Food Code (Sept 2026) · CDC: Estimates — Burden of Foodborne Illness in the United States (updated 2025) · CDC: Field Epidemiology Manual, Acute Enteric Disease Outbreaks (2024) · CDC: Foodborne outbreak basics.
6 · Safe food flow — from the delivery truck to the tray, and the temperatures that keep it safe
Simple idea: food is safe when it comes from a safe source, is kept out of the danger zone, is cooked hot enough, and is cooled and reheated fast. Each step in the "flow of food" is a chance to control germs — or to lose control. The numbers in this section are the most tested numbers in the whole topic.
1. Purchasing and receiving
- Buy only from an approved source: a supplier inspected under federal, state and local law. CMS guidance for healthcare kitchens treats home-canned or home-baked goods and produce bought from a roadside stand or farm market as not approved. Commercially filled, unopened packages (pasteurized milk, liquid pasteurized eggs, ready-made tube-feeding formula) lower the risk.
- Inspect deliveries at once: truck clean and refrigerated; packages intact; dates, inspection stamps and labels present; no signs of pests, thawing and refreezing (large ice crystals, dripping) or tampering. Reject damaged or warm product.
- Check temperatures: refrigerated Time/Temperature Control for Safety (TCS) food at 41 °F (5 °C) or below; frozen food frozen solid; shell eggs received at an air temperature of 45 °F (7 °C) or below.
2. Storage
- FIFO = first in, first out. Date items on arrival and use the oldest first; discard outdated stock.
- Store food at least 6 inches off the floor, on clean, open (slatted) shelving away from walls; never in locker rooms, toilets, garbage or mechanical rooms or under unprotected sewer lines.
- Raw animal foods below ready-to-eat foods, so drips cannot fall on food that will not be cooked again.
- Chemicals are labeled and stored apart from and never above food. Keep lot numbers when food is moved out of its original box, so a recall can be traced. Remove cardboard boxes early (moisture, pests).
- APIC gives typical storage ranges: dry storage about 50–70 °F (10–21 °C), meats and dairy about 32–40 °F (0–4 °C), frozen food about −10 to 0 °F (−23 to −18 °C).
3. TCS food and the danger zone
TCS food (formerly "potentially hazardous food") needs time and temperature control to stop germ growth or toxin formation: meat, poultry, fish, eggs, dairy, cooked rice, beans and potatoes, cut melons, cut tomatoes, cut leafy greens, raw sprouts, garlic-in-oil.
4. Cooking end-points (FDA Food Code, current)
| Minimum internal temperature | Foods |
|---|---|
| 165 °F (74 °C), instantaneous | Poultry; stuffed meat, fish, pasta or poultry; stuffing with meat; wild game. Raw animal foods cooked in a microwave: 165 °F in all parts, then cover, rotate or stir, and let stand 2 minutes |
| 155 °F (68 °C) for 17 seconds | Ground (comminuted) meat and fish, injected or mechanically tenderized meat, ratites, raw eggs pooled or held for later service (e.g., buffet scrambled eggs) |
| 145 °F (63 °C) for 15 seconds | Intact whole cuts of meat (steaks, chops), fish, raw eggs broken for one order and served at once |
| 145 °F (63 °C) for 4 minutes | Whole meat roasts (other time–temperature pairs allowed) |
| 135 °F (57 °C) | Fruits and vegetables cooked for hot holding |
Measure in the thickest part, not touching bone; for thin items insert from the side. Clean and sanitize the probe between foods. Older sources (e.g., APIC Text 2014, using the 2009 Food Code) list 165 °F for 15 seconds for poultry and 155 °F for 15 seconds for ground meat.
5. Cooling, reheating, thawing, date marking
| Step | Current rule |
|---|---|
| Cooling cooked food | 135 → 70 °F within 2 hours, and 135 → 41 °F within a total of 6 hours. Food made from room-temperature ingredients (e.g., canned tuna salad): to 41 °F within 4 hours |
| Cooling methods | Shallow pans, smaller portions, ice-water bath with stirring, blast chiller, ice as an ingredient; containers loosely covered and not stacked |
| Reheating for hot holding | All parts to 165 °F for 15 seconds, reached within 2 hours. Commercially processed ready-to-eat food from an unopened package: 135 °F. Never reheat in hot-holding equipment (steam tables hold heat; they do not reheat) |
| Thawing | In the refrigerator at 41 °F or below; under cold running water at 70 °F or below; in the microwave only if cooking follows at once; or as part of cooking. Never on the counter |
| Date marking | Ready-to-eat TCS food kept refrigerated longer than 24 hours: label it, use within 7 days at 41 °F or below; the day it was made is day 1 |
| Time as a public health control | With written procedures, TCS food may be held without temperature control for up to 4 hours (then served, cooked or discarded), or up to 6 hours for cold food that starts at 41 °F and never goes above 70 °F. Not allowed for raw eggs in an HSP facility |
6. Thermometers and temperature logs
Use a probe thermometer that is accurate to ±2 °F (±1 °C) for food; air and water thermometers in refrigerators must be accurate to ±3 °F (±1.5 °C). Calibrate on a schedule (for example in an ice-water bath) and after a drop. Every refrigerator, freezer, cart and hot-holding unit has a log: who checked, the reading, and what was done when the reading was out of range. A log that shows a bad reading with no corrective action is a survey finding.
7. What to do after a cold-holding excursion
Example: the night log of a walk-in refrigerator reads 48 °F at 22:00 and 50 °F at 06:00; nobody acted.
- The Food Code's longest allowance for TCS food without temperature control is 4 hours (time as a public health control, with written procedures). Food warmer than 41 °F for longer than that, or for an unknown time, is not made safe by putting it back in the cold. ⚑ Not verified: the exact disposition of food held above 41 °F for less than 4 hours is decided by the local regulatory authority and the facility's written policy; FDA's inspection annex asks how long the food was out of control, whether hazards such as C. perfringens or B. cereus could be present, and whether reheating can remove them.
- Non-TCS items (whole raw fruit, bread, sealed shelf-stable products) are not affected.
- Then fix the system: service or replace the unit, add an alarm or continuous monitoring, and train staff that an out-of-range reading requires action and a note.
8. HACCP — the prevention system
Hazard Analysis and Critical Control Point (HACCP) is a written, prevention-based plan for biological, chemical and physical hazards (including allergens). A critical control point (CCP) is a step where control is applied and a hazard is prevented, removed or reduced to a safe level — for example cooking, cooling, hot and cold holding, receiving. A critical limit is the measurable value at that step, such as "cool to 70 °F within 2 hours".
| # | HACCP principle | Example |
|---|---|---|
| 1 | Conduct a hazard analysis | Chicken salad: Salmonella, Listeria, slow cooling |
| 2 | Find the critical control points | Cooking, cooling, cold holding |
| 3 | Set critical limits | 165 °F; 2 + 4 hours cooling; 41 °F holding |
| 4 | Monitor the CCPs | Probe readings logged by a named person |
| 5 | Take corrective action when a limit is missed | Reheat, re-cook, or discard; fix the cause |
| 6 | Verify that the system works | Supervisor reviews logs, checks thermometer calibration |
| 7 | Keep records | Logs, corrective actions, training, calibration |
The FDA and USDA lists put verification as principle 6 and record-keeping as principle 7; some older texts reverse the two. Learn the idea rather than the number.
Tray and unit (floor) food
- Send trays in temperature-controlled or insulated carts and check cart temperatures. If the patient is away, keep or replace the tray; do not leave it at room temperature.
- Unit refrigerators: label and date patient food; check daily; APIC advises discarding prepared perishable food after 48–72 hours and open cans of nourishment after 24 hours.
- Vending machines with TCS food must hold 41 °F or below or 135 °F or above and stop selling if the temperature fails.
How the exam asks it
- "Correct cold-holding temperature?" → 41 °F (5 °C) or below.
- "A 10-gallon pot of chili is put in the walk-in to cool. BEST correction?" → divide into shallow pans or use an ice bath or blast chiller.
- "Leftover soup needs reheating for the steam table." → 165 °F within 2 hours on the stove, then hold at 135 °F or above.
- "Refrigerator log shows 50 °F overnight; FIRST action?" → check food temperatures and time, discard TCS food that was out of control too long, then repair and document.
Sources: APIC Text, Ch.111 Nutrition Services — 'Purchasing', 'Receiving', 'Storage of Food', 'Food Production System', 'Safe Handling' (Table 111-1), 'Prevention Strategies for Safe Food', 'Holding and Serving Prepared Foods', 'Overproduction', 'Hazard Analysis and Critical Control Point', 'Vending Machine Guidelines' · FDA: Food Code 2022 (§§3-401.11, 3-401.12, 3-403.11, 3-501.13, 3-501.14, 3-501.15, 3-501.16, 3-501.17, 3-501.19, 4-203.11, 4-203.12; Annex 5 risk-based inspections) · FDA: Summary of Changes in the 2026 FDA Food Code (Sept 2026; no change to holding temperatures) · FDA: Hazard Analysis Critical Control Point (HACCP) principles.
7 · Food staff and kitchen hygiene — hands, ill workers, sanitizing, ice, feeds and pests
Simple idea: the most common germs in hospital food outbreaks — norovirus, hepatitis A, Shigella, Staphylococcus aureus — come from people, not from the food itself. So the strongest protections are clean hands, no bare-hand contact with ready-to-eat food, and keeping ill workers away from food. The second group of protections is clean and sanitized equipment, safe ice and water, and a building that keeps pests out.
Hand hygiene in the kitchen
- The FDA Food Code hand wash takes at least 20 seconds: wet with clean, running warm water; apply soap; rub hard for 10–15 seconds (fingertips, between fingers, under nails, exposed arms); rinse; dry with a single-use towel or approved dryer; use a towel to turn off a hand-operated tap.
- The current Food Code requires a hand sink to deliver water of at least 85 °F (29.4 °C). Older sources (e.g., APIC Text 2014) give a minimum of 100 °F.
- Hand sinks are for hands only (not for food or utensils), stocked with soap and towels, and easy to reach; local rules decide how many.
- Wash: before starting work and before putting on gloves; after the toilet; after touching raw meat, poultry, fish or eggs and before touching ready-to-eat food; after coughing, sneezing, eating, drinking or smoking; after touching hair, face or dirty surfaces; after taking out garbage, handling chemicals or dish-room work; when changing tasks; after removing gloves.
- Hand antiseptics may be used after washing, not instead of it, in food work.
Other personal rules: short, clean fingernails, and no nail polish or artificial nails unless intact gloves are worn; no jewelry on hands and arms except a plain ring (the 2026 Food Code also allows medically needed devices); hair restraints; clean outer clothing; eat, drink and smoke only in set areas.
Ill food workers — report, exclude, restrict
Food workers must report to the person in charge, in a way that can be checked, these symptoms: vomiting, diarrhea, jaundice, sore throat with fever, and an infected (pus) skin lesion that is open or draining. They must also report these diagnoses — the "Big 6": norovirus, hepatitis A virus, Shigella, STEC, typhoid fever (Salmonella Typhi) and nontyphoidal Salmonella — and certain exposures (for example a household member with one of these, or eating a food linked to a confirmed outbreak).
| Situation | Action (food establishment serving an HSP) |
|---|---|
| Vomiting or diarrhea (infectious cause possible) | Exclude (send home). If not diagnosed: may return when free of symptoms for at least 24 hours or with a note that the cause is not infectious |
| Diagnosed norovirus, Shigella or STEC | Exclude; in an HSP setting the exclusion stays until the Food Code clearance criteria are met (time without symptoms, or negative tests, or health-authority approval) |
| Jaundice (onset in last 7 days) or hepatitis A | Exclude; the person in charge notifies the regulatory authority |
| Typhoid fever (or within past 3 months, untreated) | Exclude; release only with health-authority approval |
| Sore throat with fever | Exclude in an HSP facility (restrict elsewhere) |
| Infected lesion on hand or wrist | Restrict unless covered by an impermeable cover and a single-use glove |
| Any Big 6 diagnosis | Person in charge notifies the regulatory authority |
Exclude = not allowed in the food establishment; restrict = may work but not with exposed food, clean equipment, utensils, linens or single-service items. The 2026 Food Code adds a written employee illness policy and, for reinstating workers diagnosed with STEC, Shigella or nontyphoidal Salmonella, two consecutive negative results from a validated test where testing is used. In a hospital, the FNS manager, employee health and the IP use the same rules, and kitchens must have a written procedure for cleaning up vomit and diarrhea.
Cleaning and sanitizing
Cleaning removes food and soil; sanitizing reduces germs on a clean surface to a safe level. Sanitizer does not work well on a dirty surface. Manual dishwashing uses a three-compartment sink: wash → rinse → sanitize → air dry. Never dry dishes with a towel; store cups and glasses inverted; do not nest wet items.
| Method | Current Food Code minimum |
|---|---|
| Chlorine, manual or machine | 25–49 mg/L at 120 °F; 50–99 mg/L at 75–100 °F (depending on pH); 100 mg/L at 55 °F; contact at least 10 seconds (7 seconds for 50 mg/L in the right conditions) |
| Iodine | 12.5–25 mg/L, at least 68 °F, pH 5 or lower; 30 seconds |
| Quaternary ammonium | Concentration on the EPA-registered label, at least 75 °F, water hardness within label limits; 30 seconds |
| Hot water, manual immersion | At least 171 °F (77 °C) for 30 seconds |
| Hot water dish machine | Final sanitizing rinse at least 180 °F at the manifold (165 °F for a stationary-rack, single-temperature machine); dish surface must reach 160 °F |
Check concentration with test strips and machine temperatures with a gauge or temperature-indicating label every shift, and log them. Wiping cloths are kept in sanitizer solution between uses and are used for nothing else. Cutting boards must be nonabsorbent and replaced when deeply scored; separate boards for raw meat, produce and cooked food help prevent cross-contamination. Clean as you go; post cleaning schedules (what, when, how, with which chemical); keep safety data sheets for chemicals.
Ice and water
- Ice is food. Make it only from potable water; keep bins covered; use a nonbreakable scoop with a handle, stored outside the ice in a clean holder; never use hands or a glass to scoop.
- Do not store food, drinks or specimens in ice meant for consumption. Ice used to chill bottles, melons or equipment coils must not then be served.
- Clean and sanitize ice machines on the manufacturer's schedule; CDC's environmental guideline links contaminated ice and ice machines to outbreaks (for example nontuberculous mycobacteria, Legionella), so the IP should include them in water-management and environmental rounds.
- Plumbing: prevent cross-connections between drinking water and waste lines with air gaps and backflow devices; no food storage under leaking or unshielded sewer lines.
Enteral feeds, infant formula and breast milk
- Prefer commercially prepared, closed-system tube feeds and ready-to-feed formulas. If formula must be mixed, use a clean, separate preparation area with a hand sink, liquid soap and single-use towels; clean equipment; hair cover and gloves; label each container with product, date, time and initials; never use raw eggs.
- APIC hang-time limits: open-system formula decanted from a can about 8 hours; formula reconstituted from powder 4 hours; reusable bags and bottles discarded every 24 hours.
- CDC (2026): prepared infant formula — use within 2 hours, and within 1 hour once feeding starts; refrigerate and use within 24 hours if not used; throw out what is left after a feeding. For infants younger than 2 months, preterm or immunocompromised infants, powdered formula should be mixed with water at about 158 °F (70 °C) to kill Cronobacter, or a liquid product used.
- Expressed breast milk (CDC 2026): room temperature up to 4 hours, refrigerator up to 4 days, freezer best within 6 months (12 months acceptable); use thawed milk within 24 hours in the refrigerator; never refreeze; never microwave; discard leftovers within 2 hours after a feeding.
- Wrong breast milk given to an infant: follow the incident policy and inform risk management (APIC treats it as an exposure event). CDC's steps: tell the mother whose milk was given and ask about her health, medicines and how the milk was handled; tell the receiving infant's parents that the risk of infection is small; and let the child's physician decide on any testing. Prevent it with labels, two-person or barcode checks at feeding time.
Food from home
Food that family brings for one patient is not part of the kitchen's approved-source chain, so the facility needs a policy (developed by nursing, FNS and the IP): label it with the patient's name and date, store it in a patient-food refrigerator, discard it on schedule, and never serve it to other patients. Home-canned or home-made food must not enter the FNS food supply. (⚑ Not verified: details of food-from-home policies vary by facility; APIC and CMS address only approved sources for the kitchen.)
Waste and integrated pest management
- Garbage containers: leak-proof, easy to clean, with tight lids; removed from the kitchen often; outside containers on smooth, nonabsorbent surfaces; washed where a floor drain goes to the sanitary sewer.
- Integrated pest management (IPM) means prevention first: seal cracks and gaps, repair screens and doors, inspect deliveries, keep areas clean and dry, rotate stock, and use a licensed pest-control operator who inspects, identifies the cause and reports conditions that attract pests. Pesticides are only one tool, applied by the licensed operator.
- Only FNS staff and people on FNS business should enter food preparation areas.
How the exam asks it
- "A cook calls in with vomiting since last night. Return?" → after 24 hours without symptoms (if not diagnosed), per policy.
- "A worker making sandwiches without gloves." → stop; use utensils or gloves after hand washing; no bare-hand contact for an HSP.
- "BEST storage for the ice scoop?" → in a clean holder outside the ice.
- "Hot-water manual sanitizing?" → 171 °F for 30 seconds.
Sources: APIC Text, Ch.111 Nutrition Services — 'Basic Principles', 'Personnel Policies', 'Hand Washing', 'To Prevent Cross-contamination', 'Ice', 'Formulas', 'Cleaning, Sanitizing, and Equipment Maintenance' (Tables 111-2 and 111-3), 'Environmental Concerns', 'Management of Waste and Pest Control', 'Guidelines For Food And Nutrition Responsibilites' · FDA: Food Code 2022 (§§2-201.11, 2-201.12, 2-201.13, 2-301.12, 3-301.11, 3-303.11, 4-501.111, 4-501.112, 4-501.114, 4-703.11, 5-202.12) · FDA: Summary of Changes in the 2026 FDA Food Code (Sept 2026) · CDC: Infant Formula Preparation and Storage (2026) · CDC: Breast Milk Storage and Preparation (2026) · CDC: What to Do If an Infant or Child Is Mistakenly Fed Another Mother's Milk (2026) · CDC: Guidelines for Environmental Infection Control in Health-Care Facilities (2003).
8 · Pharmacy and infection prevention — partners, contaminated products and drug diversion
Simple idea: a medicine that should be sterile can carry germs straight into the blood. When that happens, many patients can be infected at the same time with the same organism. The pharmacy prepares, stores and recalls medicines; the infection preventionist (IP) watches infections and finds clusters. Together they find the product, stop its use and protect patients.
What the pharmacy does for infection prevention
- Prepares and stores sterile medicines — compounded sterile preparations (CSPs) such as intravenous (IV) admixtures, parenteral nutrition (PN) and syringes.
- Trains other compounders — nurses, anesthesia staff, respiratory therapists, dialysis staff and clinic staff also prepare sterile doses. Pharmacy should help teach and check their aseptic technique.
- Coordinates recalls — removes a recalled lot from every unit and helps trace which patients received it.
- Inspects patient care areas — removes expired drugs and checks medication refrigerators and storage.
- Formulary and product decisions — for example choosing single-dose vials, prefilled syringes or ready-to-use products that need less manipulation.
- Antimicrobial stewardship — the right drug, dose, route and duration; restriction and approval programs; usage data; computer order sets; patient-specific advice with physicians. Goals: better outcomes, less resistance, less Clostridioides difficile infection, lower cost.
- Staff health — pharmacists may give vaccines and help choose post-exposure prophylaxis with occupational health. Pharmacy staff need the same immunity evidence as other healthcare personnel.
What the IP gives the pharmacy
The IP brings expertise on cleaning and disinfection, hand hygiene, gowning and gloving, environmental sampling, and adult education. The IP joins environment of care rounds in the pharmacy and helps with a gap analysis / risk assessment of compounding practice. The infection prevention committee should review the sterile compounding quality plan (training, competency, facility, environmental monitoring) and stewardship data. Two surveillance streams meet here: the pharmacist tracks antimicrobial use, the IP tracks resistant organisms; together they see whether use patterns drive multidrug-resistant organisms (MDROs).
Intrinsic vs extrinsic contamination
| Intrinsic | Extrinsic | |
|---|---|---|
| When it happens | During manufacture (or transport) — before the product reaches the facility | After manufacture — during compounding, storage, or use at the bedside |
| Typical pattern | Cases in many facilities, often in many states, linked to one lot | Cases in one unit or one facility, linked to one practice, person or area |
| Examples | Contaminated albuterol or saline for respiratory therapy; endotoxin in IV products; the 2012 compounded steroid outbreak | Propofol drawn up early and left at room temperature; one dextrose bag used for many heparin infusions near a sink; reused syringes |
| Key action | Quarantine the lot, report to the Food and Drug Administration (FDA) MedWatch and public health, recall | Observe and correct practice; re-train; remove the product in use |
Both are less common than infection from the catheter itself, but when infusate is contaminated, bacteremia and septic shock are more likely. Most infusate outbreaks are caused by aerobic Gram-negative rods: Klebsiella, Enterobacter, Serratia, Citrobacter freundii, Burkholderia cepacia, Ralstonia pickettii. Endotoxin alone (no live bacteria) can also cause fever and sepsis-like reactions. Fungi (Candida parapsilosis, C. albicans) are linked with PN.
Which fluids let germs grow?
- Lipid products (propofol, fat emulsions) support rapid growth at room temperature — near-neutral pH and lots of fat. This is why propofol must be drawn up just before use and its tubing changed often.
- 5% dextrose supports Klebsiella, Enterobacter, Serratia and B. cepacia. Distilled water supports B. cepacia, Pseudomonas, Acinetobacter and Serratia. Many bacteria can survive in normal saline.
- PN (dextrose + amino acids) inhibits most bacteria but lets Candida grow slowly; adding albumin or lipid (3-in-1 mixtures) raises the risk.
- Many concentrated drug infusions (some opioids, vasopressors) are hostile to bacteria — but do not rely on this.
Outbreaks from compounding pharmacies
Before 2012, outbreaks from compounded drugs had already caused hundreds of infections (for example Serratia from betamethasone, Exophiala from methylprednisolone, B. cepacia from heparin flush). In 2012, contaminated preservative-free methylprednisolone acetate injections (epidural and joint) from one compounding pharmacy caused the multistate fungal meningitis outbreak: CDC counted 753 cases and 64 deaths in 20 states, mostly due to the mold Exserohilum rostratum. Infections appeared weeks to months after injection. This outbreak led to the Drug Quality and Security Act (2013) and the FDA category of 503B outsourcing facilities (section 10).
Drug diversion
Diversion means a worker takes a controlled drug (often an injectable opioid such as fentanyl) for personal use. If the worker injects part of a syringe and refills it with saline, or reuses the patient's syringe, the drug that the patient gets can carry the worker's hepatitis C virus (HCV) or bacteria. CDC lists outbreaks of HCV and of Gram-negative bloodstream infections (Serratia marcescens, Sphingomonas paucimobilis, Achromobacter, Ralstonia pickettii) caused by tampering. Patients may also get no pain relief, and an impaired worker gives unsafe care.
When diversion is suspected (CDC Clinician Brief: Drug Diversion, 2024): assess patient harm, consult public health when tampering may have harmed patients, report promptly to law enforcement and regulators (for example the Drug Enforcement Administration and the licensing board). Prevention: secure storage, automated dispensing logs, waste witnessing, and active monitoring to detect unusual use.
What the IP does when a product-related cluster is suspected
How the exam asks it
- "Cases in several hospitals, same lot number" → intrinsic contamination; quarantine the lot, report to FDA and public health.
- "Cluster on one unit after a practice change" → extrinsic; observe preparation and use.
- "FIRST action when a contaminated product is suspected?" → remove from use and sequester the remaining product (keep for testing).
- "Who coordinates a recall inside the hospital?" → pharmacy, with the IP tracing exposed patients.
Sources: APIC Text, Ch.112 Pharmacy Services — 'Background', 'Basic Principles', 'Intrinsic Contamination', 'Extrinsic Contamination', 'Modes of Contamination of Sterile Pharmaceutical Products and Preparations', 'Pharmacist Responsibilities Involving Antimicrobial Stewardship', 'Infection Preventionist Partnership with the Pharmacy' · CDC: Clinician Brief: Drug Diversion (2024) · CDC: Multistate Outbreak of Fungal Meningitis and Other Infections (2012–2013, final case count) · FDA: Compounding and the FDA: Questions and Answers (2025).
9 · Safe injection practice, vials, storage and hang times
Simple idea: a needle or syringe that touched one patient is dirty. If it goes back into a shared vial or bag, the vial is now dirty for the next patient. Most hepatitis B and C outbreaks from injections happened in outpatient clinics because staff reused syringes or shared vials. The rule is CDC's One & Only: one needle, one syringe, only one time.
The core injection safety rules (CDC)
- Use a new sterile needle and syringe for every patient and every entry into a vial. Never reuse a syringe for another patient, even if you change the needle or inject through IV tubing.
- Prepare injections with aseptic technique in a clean area, away from sinks, splashes and used equipment.
- Disinfect the rubber septum with alcohol before every entry and let it dry. The septum under the flip cap is not guaranteed sterile.
- Never use bags or bottles of IV solution as a shared source for several patients.
- Insulin pens, fingerstick lancing devices and glucose meters: one pen per patient; never share a pen, even with a new needle (blood can flow back into the cartridge).
Types of containers
| Container | Preservative? | Rule |
|---|---|---|
| Single-dose vial (SDV) / ampule / IV bag | No | One patient, one procedure, one entry. Never pool leftovers or save them, even for the same patient. Choose the smallest vial size needed. Exception: in a shortage, pharmacy may repackage an unopened SDV for several patients only under USP <797> conditions (ISO Class 5). |
| Multiple-dose vial (MDV) | Yes (antimicrobial preservative) | Dedicate to one patient whenever possible. Date it when first opened; discard 28 days after first entry unless the manufacturer gives a different (shorter or longer) date — and never after the manufacturer's expiry date. |
| Pharmacy bulk package (PBP) | Usually no | Many doses in one container (antibiotics, contrast, concentrated electrolytes) for use only in an ISO Class 5 hood by pharmacy. Never for direct patient use on a unit. Use within the time on the labeling. |
Why 28 days?
The USP test for preservatives (USP <51> Antimicrobial Effectiveness Testing) checks that the preservative suppresses organisms introduced over a 28-day period of repeated withdrawals. So USP <797> and CDC use a 28-day beyond-use date (BUD) for opened MDVs, unless the manufacturer says otherwise. The preservative does not kill viruses such as HCV, and it works less well in the refrigerator — so it is no excuse for poor technique.
When to discard any vial
- Visible contamination, cloudiness or particles, or suspected contamination (for example the septum was touched or the vial was in a patient room).
- BUD reached (MDV 28 days or manufacturer date), or empty.
- Manufacturer's expiration date reached (this date applies only to the unopened vial).
- Vial not dated after opening — treat as unsafe and discard.
Medication refrigerators and storage
- Medication refrigerators on units: check and record temperature at least daily (log dated and signed, or electronic). Bulk storage in pharmacy: continuous monitoring with high/low alarms.
- Vaccines (CDC Vaccine Storage and Handling Toolkit): refrigerator 2–8 °C (36–46 °F), freezer −50 to −15 °C; use a digital data logger with continuous monitoring and check and record the minimum and maximum temperatures at the start of each workday. Older sources (e.g., APIC Text 2014) say "check twice a day".
- Out-of-range temperature: label the products "do not use", keep them in proper storage, fix the unit, document, and ask the manufacturer or pharmacy before using them. Do not discard vaccine before this check.
- No food or drinks and no specimens in medication refrigerators.
Hang times and tubing change (CDC intravascular catheter guideline)
The USP BUD runs from compounding until administration starts. Once the infusion is hung, CDC hang-time and tubing rules apply.
| Infusion | Complete infusion within | Change the administration set |
|---|---|---|
| Ordinary continuous fluids (no blood, no lipid) | No CDC limit — follow the manufacturer | No more often than every 96 hours, but at least every 7 days |
| Lipid-containing PN (3-in-1) | 24 hours | Within 24 hours |
| Lipid emulsion alone | 12 hours (24 hours only if volume needs it) | Within 24 hours |
| Blood or blood products | 4 hours | Within 24 hours |
| Propofol | Per manufacturer | Every 6 or 12 hours, when the vial is changed (per manufacturer) |
Needleless connectors: change no more often than every 72 hours (or per manufacturer), and with the administration set. Older sources (e.g., APIC Text 2014) give a 24-hour hang time for fat emulsion alone; CDC's guideline says 12 hours for lipid emulsion alone.
Other shared containers
- Multi-dose eye drops and ointments: contaminated tips and caps have caused Serratia and Pseudomonas eye infections. Dedicate to one patient where possible, do not touch the tip to the eye, and follow labeling and policy for discard.
- Albuterol and saline for respiratory therapy: carrying open MDVs in pockets for days caused a B. cepacia outbreak. Prefer single-dose units.
- Contrast media, flush syringes, local anesthetics: single-patient use; prefilled flush syringes are preferred.
How the exam asks it
- "A nurse uses one 10-mL saline SDV to flush three patients' lines" → unsafe; one SDV = one patient.
- "An MDV of lidocaine is kept on the procedure tray in the patient room" → it must be dedicated to that patient or kept in the medication area.
- "An undated opened MDV is found" → discard.
- "A patient on lipid emulsion alone — when must the bag finish?" → within 12 hours.
Sources: APIC Text, Ch.112 Pharmacy Services — 'Modes of Contamination of Sterile Pharmaceutical Products and Preparations', 'Methods for Preventing Contamination of Compounded Sterile Preparations', 'Storage of Pharmaceuticals' · CDC: Preventing Unsafe Injection Practices (2024) · CDC: One & Only Campaign · CDC/HICPAC: Guidelines for the Prevention of Intravascular Catheter-Related Infections (2011; updated 2017), Summary of Recommendations (page 2024) · CDC: Vaccine Storage and Handling Toolkit · USP General Chapter <797> (2023) and <51>.
10 · Sterile compounding — USP <797>, USP <800> and 503A/503B
Simple idea: mixing a sterile drug creates a chance for germs from air, hands and surfaces to enter it. The United States Pharmacopeia (USP) General Chapter <797> sets minimum rules for clean air, clean people, clean surfaces and safe time limits. It applies to everyone who compounds sterile preparations — pharmacists, technicians, nurses, physicians — in every place (hospital, clinic, physician office). The current revision became official on 1 November 2023.
The air: primary engineering controls and rooms
- Primary engineering control (PEC): the device that gives ISO Class 5 unidirectional (first-air) flow at the work surface — laminar airflow workbench, biological safety cabinet (BSC), or compounding aseptic isolator. ISO 5 = no more than 3,520 particles ≥0.5 µm per cubic meter.
- Cleanroom suite: an ISO Class 7 buffer room (holds the PEC) entered through an ante room (ISO Class 8, or ISO 7 if it opens into a negative-pressure hazardous drug room). The buffer room is under positive pressure to the ante room; HEPA-filtered air.
- Segregated compounding area (SCA): an unclassified space with a PEC in it, kept away from traffic and at least 1 meter from sinks. Only Category 1 CSPs may be made here.
- Certification of PECs and rooms by a qualified person at least every 6 months, and after moving the device or major service.
The 2023 categories and beyond-use dates (BUDs)
The BUD is the time after which the CSP must not be used (stored or started). It is counted from the time of compounding.
| Type | Where made | BUD (room temp / refrigerated) |
|---|---|---|
| Immediate-use CSP | Outside a PEC, in emergencies or when delay would harm the patient; simple transfer of no more than 3 different sterile products | Administration must begin within 4 hours of the start of preparation |
| Category 1 | PEC in an SCA (or in a cleanroom suite) | ≤12 hours room temperature / ≤24 hours refrigerated |
| Category 2 | PEC in a cleanroom suite | Longer — e.g., aseptic, sterile ingredients, no sterility test: 4 days room / 10 days fridge / 45 days frozen; with any nonsterile ingredient: 1 / 4 / 45 days; longer if sterility tested or terminally sterilized (up to 45 / 60 / 90 days) |
| Category 3 | Cleanroom suite with extra requirements (sterility and endotoxin testing, more frequent monitoring, sterile garb, no exposed skin) | Longest — 60 to 180 days depending on method and storage |
Older sources (e.g., APIC Text 2014, based on the 2008 chapter) use low-, medium- and high-risk levels, a "low-risk 12-hour" level, and an immediate-use limit of 1 hour. The 2023 chapter replaced these with Categories 1–3 and a 4-hour immediate-use limit.
Opened containers in the pharmacy
- A single-dose container opened only in ISO Class 5 or cleaner air may be used for up to 12 hours after first puncture (unless the manufacturer says less). Older sources (e.g., APIC Text 2014) say 6 hours. Opened ampules may not be stored.
- MDV: 28 days after first entry unless the manufacturer states otherwise.
- Pharmacy bulk package: only in ISO Class 5, within the time on its label.
The people: hand hygiene, garb, competency
- Remove jewelry, cosmetics and nail products; no artificial nails.
- Garb in order from "dirtiest" to "cleanest": shoe covers, head and facial-hair covers, face mask → wash hands and forearms to the elbows for at least 30 seconds → low-lint gown closed at the neck with snug wrists → alcohol-based hand rub → sterile gloves. Gloves are disinfected with sterile 70% isopropyl alcohol during work.
- Competency, before compounding alone and then ongoing: garbing and hand hygiene with a gloved fingertip and thumb test (initially 3 times, with zero growth), aseptic technique with a media-fill test, and written/observed training. Repeat at least every 6 months for Category 1 and 2 (every 3 months for Category 3).
Environmental monitoring and cleaning
- Air and surface sampling are required in USP <797> — this is different from CDC's advice against routine environmental cultures in ordinary hospital areas. Viable air sampling at least every 6 months; surface sampling at least monthly (Categories 1–2; more often for Category 3).
- If growth is over the action level, identify the organism to at least the genus level, investigate, clean, retest; highly pathogenic organisms (e.g., molds, S. aureus, Gram-negative rods) need action whatever the count (⚑ Not verified in the 2023 text).
- Cleaning: PEC work surface and floors daily (and work surface after spills and between batches); walls, ceilings and storage shelves monthly; a sporicidal agent at least monthly (Categories 1–2). Clean from clean to dirty, top to bottom, with low-lint wipes and EPA-registered agents; sterile 70% isopropyl alcohol on the PEC surface.
- Wipe vial stoppers and ampule necks with sterile 70% alcohol before entry.
USP <800> hazardous drugs
Hazardous drugs (HDs, e.g., many chemotherapy agents) must protect the worker as well as the product. Sterile HDs are compounded in a containment PEC (Class II or III BSC, or compounding aseptic containment isolator) that is externally vented, in a room under negative pressure (0.01–0.03 inch water column) with at least 30 air changes per hour (or 12 in a containment segregated compounding area). HDs are stored separately in a negative-pressure room. Staff wear two pairs of chemotherapy gloves and HD gowns. USP <800> became fully applicable with the 2023 <797>.
Who regulates? 503A vs 503B
| 503A compounding pharmacy | 503B outsourcing facility | |
|---|---|---|
| Main overseer | State board of pharmacy (FDA can inspect) | FDA (risk-based inspections) |
| Prescription | Patient-specific prescription needed | May compound without patient-specific prescriptions (for office/hospital stock) |
| Quality standard | USP <797>/<800> and state law | Federal current good manufacturing practice (CGMP) |
| Registration and reporting | State license | Registers with FDA; reports products and adverse events to FDA |
503B was created by the Drug Quality and Security Act (2013) after the 2012 fungal meningitis outbreak.
How the exam asks it
- "A nurse mixes an antibiotic on the unit for an emergency" → immediate-use; start within 4 hours.
- "Pharmacy has only a hood in an unclassified room" → Category 1 only (12 h room / 24 h fridge).
- "A technician's gloved fingertip test grows colonies" → stop independent compounding, retrain, retest.
- "Mold on a cleanroom surface sample" → identify, investigate, clean with sporicidal agent, resample.
- "The IP's role in the pharmacy cleanroom" → review monitoring data and cleaning, advise on disinfectants and technique, join rounds; consulted at once if a CSP is suspected in infections.
Sources: APIC Text, Ch.112 Pharmacy Services — 'Methods for Preventing Contamination of Compounded Sterile Preparations', 'Environmental Sampling and Testing', 'Aseptic Technique', 'Pharmacist Participation in Infection Prevention and Control Committee' · USP: General Chapter <797> Pharmaceutical Compounding—Sterile Preparations (revision official 1 Nov 2023) and FAQs · USP: General Chapter <800> Hazardous Drugs—Handling in Healthcare Settings · FDA: Compounding and the FDA: Questions and Answers (2025); Human Drug Compounding Laws (503A/503B).
11 · Decisions, numbers and traps
Simple idea: exam scenarios in this topic ask you to choose the right first action, read a number (a temperature, a time, a date, a rate), and avoid an old rule that has changed. This section puts them side by side.
First-action rules
| Situation | FIRST action |
|---|---|
| Several patients and staff have vomiting and diarrhea after the same lunch | Save and refrigerate the leftover suspect food (same batch), then notify IP and the health department; do not throw it away |
| Kitchen walk-in refrigerator log shows 50 °F (10 °C) since last night | Find how long the food was above 41 °F (5 °C); discard time/temperature control for safety (TCS) food that was too warm too long; repair the unit; document — never just re-chill and serve |
| Cook reports diarrhea before the shift | Exclude from food work; report diagnosed norovirus, hepatitis A, Shigella, Shiga toxin–producing E. coli (STEC) or Salmonella to the health department |
| A culture tube breaks inside a centrifuge | Stop, wait for aerosols to settle (keep the lid closed), then decontaminate the rotor and bucket with the right disinfectant, wearing PPE |
| Clinical lab grows a possible Brucella or Francisella | Work in a BSC with BSL-3 practices, stop automated identification, notify the laboratory director and IP, and refer to the Laboratory Response Network reference lab |
| Cluster of the same Gram-negative organism in blood cultures of patients who all got one compounded product | Quarantine the product and lot, save isolates and product, notify pharmacy, leaders, the health department and FDA MedWatch |
| New hepatitis C infections in patients who all received opioids on one unit | Think of drug diversion and tampering; involve pharmacy, leaders, public health and law enforcement; offer testing to exposed patients |
| Nurse is seen using one syringe with a new needle for a second patient's vial | Stop the practice now; the syringe is contaminated; review exposure of patients with public health |
Numbers — worked examples
1. Food-specific attack rate — finds the food most likely to blame.
2. Multiple-dose vial (MDV) date — 28 days after first entry, unless the manufacturer gives a shorter date.
3. Two-stage cooling — hot food must fall from 135 °F to 70 °F within 2 hours, and to 41 °F within 6 hours in total.
4. Immediate-use compounded sterile preparation (CSP) — administration must begin within 4 hours of the start of preparation.
Old value → current value
| Item | Older sources (e.g., APIC Text 2014) | Current guidance |
|---|---|---|
| Hot holding of food | 140 °F in places | 135 °F (57 °C) or above (FDA Food Code) |
| Compounding groups | Low / medium / high risk | Category 1, 2, 3 CSPs (USP <797>, 2023) |
| Immediate-use CSP | Begin within 1 hour | Begin within 4 hours |
| Single-dose vial opened in ISO Class 5 air | 6 hours | 12 hours (unless the label says less) |
| Shipping names | "Etiologic agent", "diagnostic specimen" | Category A (UN2814 / UN2900), Category B (UN3373) |
| Class II BSC types | A, B1, B2, B3 | A1, A2, B1, B2, C1 (BMBL 6th ed.) |
Sources: APIC Text, Ch.110 Laboratory Services — 'Laboratory Response Network', 'Centrifuges'; Ch.111 Nutrition Services — 'Addressing a Foodborne Outbreak', 'Investigating a Foodborne Outbreak'; Ch.112 Pharmacy Services — 'Extrinsic Contamination', 'Methods for Preventing Contamination of Compounded Sterile Preparations' · FDA Food Code (2022) · USP General Chapter <797> (2023) · CDC: Preventing Unsafe Injection Practices (2024) · CDC/NIH: BMBL 6th ed. (2020).
Independent study material written from the APIC Text and public CDC guidance. Not affiliated with or endorsed by CBIC or APIC. Questions are original practice items, not examination questions.
⚡ Last-Minute Review — Laboratory, Pharmacy & Nutrition Services
1. The laboratory as partner
- The lab gives IP: culture interpretation, rapid alerts of unusual organisms and clusters, the yearly antibiogram, saved isolates for typing, help in outbreaks.
- A change in test method (e.g. toxin assay → PCR for C. difficile) can raise rates without a real outbreak — ask "did the test change?"
- Rules: CMS through CLIA (non-waived labs surveyed every 2 years) + accreditors such as CAP or The Joint Commission.
- A positive culture is a result, not a diagnosis.
2. Biosafety
- BSL-1 teaching agents · BSL-2 blood-borne and most clinical work (BSC for splash/aerosol) · BSL-3 aerosol-spread serious agents (TB cultures; suspected Brucella, Francisella), inward airflow, anteroom · BSL-4 Ebola-type agents.
- BSC: Class I protects worker + environment, not product · Class II protects worker, product and environment · Class III sealed glove box. A clean bench blows air at the worker; a fume hood has no HEPA.
- Laboratory Response Network: sentinel (hospital labs: rule out or refer) → reference (public health labs) → national (CDC).
- Start with a biological risk assessment; repeat it when anything changes.
3. Lab work, shipping, waste
- No mouth pipetting, no eating, no recapping, coat stays in the lab, BSC for aerosols.
- Broken tube in a centrifuge: keep the lid closed, let aerosols settle, then decontaminate.
- Category A (UN2814 / UN2900: cultures of dangerous agents, e.g. TB culture) · Category B (UN3373: patient specimens) · always triple packaging.
- Autoclave = method of choice for lab waste; check with biological indicators (Geobacillus stearothermophilus). Tape shows heat only.
4. Foodborne illness
- Hospital patients are a highly susceptible population (HSP): no raw or undercooked animal food, no raw sprouts, no unpasteurized juice, no bare-hand contact with ready-to-eat food.
- Suspected outbreak: save and refrigerate the suspect food (same batch) → notify IP + health department → stools, menus, interviews → attack rates → control.
- Do not culture healthy food workers or food routinely.
5. Food temperatures
- Danger zone: above 41 °F (5 °C) and below 135 °F (57 °C).
- Cooking: poultry/stuffed 165 °F · ground meat 155 °F · whole roasts/fish 145 °F · reheat to 165 °F within 2 h.
- Cooling: 135 → 70 °F in 2 h, → 41 °F in 6 h total.
- Cold-holding log failure: how long above 41 °F? → discard TCS food held too warm too long → repair the unit → document. Never just re-chill and serve.
- HACCP: hazards → critical control points → limits → monitoring → corrective action → verification → records.
6. Kitchen hygiene
- Reportable symptoms: vomiting, diarrhea, jaundice, sore throat with fever, infected hand lesion. "Big 6": norovirus, hepatitis A, Shigella, STEC, typhoid, nontyphoidal Salmonella.
- A cook with diarrhea is excluded — not moved or gloved.
- Sanitizer at label strength (test it); too strong is not better. Hot-water manual sanitizing 171 °F for 30 s; dish machine final rinse 180 °F.
- Ice: scoop stored outside the ice, never hands or a glass.
- Breast milk given to the wrong infant: inform both families; the infant's doctor decides on testing.
7. Pharmacy and injections
- Intrinsic contamination = made at the factory (many hospitals) · extrinsic = during use here (one place).
- Cluster linked to a product: quarantine the lot, save isolates, notify pharmacy, health department, FDA MedWatch.
- Unusual bacteremias or new HCV in patients given opioids on one unit → think drug diversion.
- One needle, one syringe, one time. A new needle on a used syringe is still unsafe.
- SDV: one patient, one entry. MDV: 28 days after opening (or the manufacturer's shorter date), opened in a clean medication area — if it enters a patient area, dedicate it to that patient.
- Hang: blood 4 h · lipid alone 12 h · 3-in-1 PN 24 h · propofol tubing every 6–12 h · plain fluid sets 96 h to 7 days.
8. Sterile compounding
- USP <797> (2023): Category 1 (segregated compounding area, ≤ 12 h room / 24 h fridge), Category 2 (cleanroom suite, longer dates), Category 3 (extra testing). Immediate use: begin within 4 h.
- ISO Class 5 hood → ISO 7 buffer room (positive pressure) → ISO 8 ante room. Recertify every 6 months.
- Competency: gloved fingertip test (garbing) + media-fill test (aseptic process). Air and surface sampling are required here.
- USP <800> hazardous drugs: negative pressure, externally vented hood. "797 pushes out, 800 pulls in."
- 503A = traditional pharmacy compounding for a patient · 503B = FDA-registered outsourcing facility.
9. Traps
- Save the evidence, never discard it · 135 °F not 140 °F · immediate use 4 h not 1 h · Categories 1–3 not low/medium/high · tape ≠ biological indicator · routine environmental cultures only in compounding areas · method change can fake an outbreak.
Independent study material written from the APIC Text and public CDC guidance. Not affiliated with or endorsed by CBIC or APIC. Questions are original practice items, not examination questions.
🃏 Flashcards — quick recall