Press ✓ Mark section complete at the end of each section after you study it. Opening the page does not mark anything. Tap a chip to jump. Labels: 🔥 key point · 📌 remember · ⚠️ common error · 💡 understand this · 🧪 at the bench · 🧠 memory aid.
About the book and this course
Clinical Laboratory Method Evaluation in Practice
A Case-Based Guide to Verification, Validation and Ongoing Quality Monitoring
For medical laboratory technologists, supervisors and quality teams
Hassan Shawki, Laboratory Supervisor · First edition, 2026
This free course follows the book chapter by chapter. Each course page gives the full chapter: every numbered section, worked example, table, checklist and list of common errors, followed by flashcards and original practice questions.
How the course is laid out
| Course page | What it covers |
|---|---|
| Introduction (this page) | How the book is organised, the decision each chapter supports, how each chapter works, the companion files and the book's ground rules |
| Chapters 0–20 | One page per chapter, in book order, grouped in the book's four Parts |
| Final Assessment | Mixed practice questions across all chapters and the book's glossary (published after Chapter 20) |
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), title page and copyright page, pp.v–vi
How the book is organised: the order of decisions
The book follows the order in which a laboratory makes its decisions.
↓
Part II — covers the quantitative studies
↓
Part III — covers qualitative tests and special settings
↓
Part IV — turns the evidence into a decision and a routine quality plan
| Part | Title | Chapters | Printed pages |
|---|---|---|---|
| I | Deciding what the evidence must show | 0–5 | 1–107 |
| II | Quantitative performance studies | 6–14 | 109–282 |
| III | Qualitative tests and special settings | 15–16 | 283–325 |
| IV | From evidence to routine practice | 17–20 | 327–410 |
Back matter
| Item | Printed page |
|---|---|
| Glossary | 411 |
| Template A — Evaluation plan (verification or validation) | 421 |
| Template B — Verification report | 423 |
| Template C — Validation report | 425 |
| Consolidated reference list | 427 |
| Index (it uses chapter and section references) | 433 |
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), Contents, p.vii; How this book is organised, p.viii; copyright page, p.vi
Part I — Deciding what the evidence must show (Chapters 0–5)
For each chapter the book names the decision it supports and its main references.
| Ch. | Title | The decision it supports | Main references |
|---|---|---|---|
| 0 | Equipment readiness and records | Is the analyser identified, accepted and recorded, and ready for method evaluation? | ISO 15189:2022 (6.4, 8.4); CLSI EP10-Ed4, QMS13-A |
| 1 | Fit for purpose: verification, validation and the life of a test | Do we verify or validate, and what must we prove before the first patient result? | ISO 15189:2022; ISO 9000:2015; CLSI EP19-Ed3 |
| 2 | The language of error | Which kind of error are we measuring, and what does each word mean? | ISO 15189:2022; CLSI EP21-Ed2, EP29-A |
| 3 | The statistics an evaluator uses | Which calculation answers our question, and how sure are we of the answer? | CLSI EP05-A3, EP09c-Ed3 |
| 4 | Setting performance specifications before testing | How much error can this test carry and still serve its intended use? | EFLM Milan consensus (2015); EFLM Biological Variation Database; CLSI EP21-Ed2 |
| 5 | Planning the evaluation | Which studies, materials, sample sizes and criteria go into the written plan? | CLSI EP19-Ed3, EP10-Ed4 |
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (Part I table), p.viii
Part II — Quantitative performance studies (Chapters 6–14)
| Ch. | Title | The decision it supports | Main references |
|---|---|---|---|
| 6 | Precision | Is the random error small enough, and does it match the claim? | CLSI EP05-A3, EP15-A3 |
| 7 | Trueness and bias against reference materials | Is the method centred on the right value? | CLSI EP15-A3; EP32-R |
| 8 | Method comparison with patient samples | Will patient results change when we switch methods, and by how much at each decision point? | CLSI EP09c-Ed3, EP31-Ed2 |
| 9 | Linearity, measuring interval and dilution | Over what range can we report results directly, and when can we dilute? | CLSI EP06-Ed2, EP34-Ed1 |
| 10 | Detection capability | What is the lowest result we can report with confidence? | CLSI EP17-A2 |
| 11 | Interference and recovery | Which substances or sample conditions distort results, and from what level? | CLSI EP07-Ed3, EP37-Ed1, C56-A |
| 12 | Carryover | Can one sample or reagent contaminate the next result? | CLSI EP10-Ed4, EP47-Ed1 |
| 13 | Reference intervals | Can we adopt the manufacturer's or a published reference interval for our population? | CLSI EP28-A3c |
| 14 | Combining the evidence: total error and measurement uncertainty | Taken together, is the error acceptable, and what uncertainty do we report? | CLSI EP21-Ed2, EP29-A; ISO 15189:2022 |
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (Part II table), pp.viii–ix
Parts III and IV — Qualitative tests, special settings and routine practice (Chapters 15–20)
Part III — Qualitative tests and special settings
| Ch. | Title | The decision it supports | Main references |
|---|---|---|---|
| 15 | Qualitative (binary) examinations | Does a positive/negative test agree with the comparator well enough? | CLSI EP12-Ed3 |
| 16 | Special settings: point-of-care, haematology, immunoassay, lot changes and multiple analysers | What changes in the plan for these settings, and how do we keep several systems comparable? | CLSI EP26-Ed2, EP31-Ed2, EP35-Ed2, EP14-Ed4 |
Part IV — From evidence to routine practice
| Ch. | Title | The decision it supports | Main references |
|---|---|---|---|
| 17 | Investigating unexpected results | A study failed or looks odd: is it the method, the materials or the study? | CLSI EP18-A2; the study documents above |
| 18 | From validation data to a QC plan | Which control rules, how many controls and how often? | CLSI C24 (4th ed.), EP23-Ed2 |
| 19 | External quality assessment and ongoing verification | Is performance holding up once the method is in routine use? | ISO 15189:2022; CLSI C24 (4th ed.), EP14-Ed4, QMS24-Ed3 |
| 20 | Documenting the decision | What goes into the report, who signs it, and what happens next? | ISO 15189:2022; CLSI EP19-Ed3 |
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (Part III and Part IV tables), pp.ix–x
How each chapter works, and the example that runs through the book
Every chapter follows the same pattern, so you always know where you are:
↓
2. One decision, worked through with a synthetic example
↓
3. A "Reading the report" feature (Chapters 6 to 20)
↓
4. Common errors
↓
5. A checklist
↓
6. References
One example, from the first page to the last
The same creatinine example runs through the book:
| Where | What happens to the creatinine example |
|---|---|
| Chapter 0 | The analyser is accepted |
| Chapter 4 | The performance specifications are set |
| Chapters 5–19 | The worked examples plan, study, investigate and monitor the same creatinine method (for example Worked Examples 5.1, 6.1, 8.1, 17.1, 18.1 and 19.1) |
| Chapter 20 | The signed decision record |
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (closing paragraph), p.x; worked-example titles in the chapter outlines (Chapters 4–20)
Companion files
The worked examples, figures and exercises use synthetic data sets that readers can open and recalculate. The book describes them as a companion package:
| What is in the package | Details |
|---|---|
| Source data (CSV) | For every figure and worked example that has a data set, as CSV files named after the figure or table they support (for example, Fig8.1_Fig8.2_source_data.csv for Figures 8.1 and 8.2) |
| Python scripts | The scripts that generated the synthetic data sets and the QC simulations in Chapter 18, so each figure and simulated value can be reproduced, with a script (run_all.py) that runs them in the right order, since some analyses build on the output of others |
| Editable templates | The equipment-record template of Chapter 0 (Table 0.7) with its event log, Templates A to C (evaluation plan, verification report and validation report) and the verification-record entry in Table 8.B as Word documents, and the follow-up register of Table 20.6 as a spreadsheet |
| File list (README) | For each file, the chapter, table or figure it belongs to |
Every file is synthetic and illustrative, like the examples it supports. The templates are starting points: a laboratory adapts them to its own procedures and criteria.
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), Companion files, p.xi
The book's ground rules
The copyright page sets four ground rules. Keep them in mind in every chapter.
| # | Ground rule | What it means for you |
|---|---|---|
| 1 | All data sets, reports and worked examples are synthetic, created for teaching. | No real patient, analyser, company or laboratory is described. |
| 2 | Limits, schedules and roles marked as illustrative are not recommendations for any laboratory. | Do not copy an illustrative limit into your own procedure as if it were a standard. |
| 3 | Laboratories must set their own criteria for their own intended use. | The method of deciding transfers; the numbers belong to the example. |
| 4 | ISO and CLSI documents are cited for attribution and explained in the author's own words. | Consult the current editions for the full requirements and procedures. Citation does not imply endorsement by ISO, CLSI, any accreditation body or any manufacturer. |
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), copyright page, p.vi
How to use this course
Every chapter page works the same way. Use the buttons at the top of each page:
| Button | What it does |
|---|---|
| Study Mode | The full chapter, section by section. Press ✓ Mark section complete after each section; the study panel shows your progress and lets you jump to any section. |
| Flashcards | Quick recall of the chapter's key points. Flashcards never change your quiz score. |
| Quiz / Exam | Original practice questions written from the chapter. Practice mode checks each answer; exam mode shows the results after you submit. |
| Progress / Results | Your study completion, score, weak areas and the questions to review. |
| Last-Minute Review | The 10-minute version of the chapter: decisions, formulas, numbers, checklist, common errors and key terms. |
| Export / Import Progress | A backup file of your progress for that page. When you sign in on the course hub, quiz progress also syncs between your devices. |
This Introduction page has no quiz: practice questions start with Chapter 0.
Source: course guide for this site (how the pages work); book structure from Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised, pp.viii–x
Training course, not a certification. Based on the author's textbook; all examples use synthetic data. It does not replace the CLSI and ISO documents it cites, and it is not affiliated with or endorsed by CLSI or ISO.
© 2026 Hassan Shawki. Course text adapted from the author's textbook Clinical Laboratory Method Evaluation in Practice.
⚡ Last-Minute Review — Introduction: How the Book and Course Work
Read this before Chapter 0, and come back whenever you lose the thread of where a chapter fits.
The organising idea
- The book follows the order in which a laboratory makes its decisions; each chapter supports one decision.
- Part I (Ch 0–5) what the evidence must show · Part II (Ch 6–14) quantitative studies · Part III (Ch 15–16) qualitative tests and special settings · Part IV (Ch 17–20) evidence → decision and routine quality plan
One decision per chapter
- 0 equipment identified, accepted, recorded, ready? · 1 verify or validate; what must be proved before the first patient result? · 2 which kind of error; what does each word mean? · 3 which calculation; how sure? · 4 how much error can the test carry? · 5 which studies, materials, sample sizes and criteria in the written plan?
- 6 random error small enough, matches the claim? · 7 centred on the right value? · 8 will patient results change at each decision point? · 9 reportable range, when to dilute? · 10 lowest reportable result? · 11 which substances distort results, from what level? · 12 can one sample or reagent contaminate the next? · 13 adopt the manufacturer's or a published reference interval? · 14 is the combined error acceptable; what uncertainty to report?
- 15 does a positive/negative test agree with the comparator? · 16 what changes for POCT, haematology, immunoassay, lot changes, several analysers? · 17 a study failed: method, materials or study? · 18 which control rules, how many controls, how often? · 19 is performance holding up in routine use? · 20 what goes in the report, who signs, what next?
How each chapter works
- Question from the bench → one decision with a synthetic example → "Reading the report" (Ch 6–20) → common errors → checklist → references
- The same creatinine example runs from accepting the analyser (Ch 0) and setting specifications (Ch 4) to the signed decision record (Ch 20)
Companion files and ground rules
- Companion package: CSV source data · Python scripts (incl. Chapter 18 QC simulations,
run_all.py) · editable templates (Table 0.7, Templates A–C, Table 8.B, Table 20.6) · README file list · "available from the author" - All data synthetic · illustrative limits are not recommendations · laboratories set their own criteria · ISO/CLSI cited for attribution, in the author's words; citation ≠ endorsement
- Back matter: Glossary · Templates A (evaluation plan), B (verification report), C (validation report) · consolidated references · index by chapter and section
Training course, not a certification. Based on the author's textbook; all examples use synthetic data. It does not replace the CLSI and ISO documents it cites, and it is not affiliated with or endorsed by CLSI or ISO.
Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), front matter pp.v–xi
🃏 Flashcards — quick recall
Tap the card (or press Space) to see the answer · 1 = Review again · 2 = Known · ← → move. Flashcards never change your quiz score.