← Course Hub
METHOD EVALUATION COURSE · INTRODUCTION

Introduction: How the Book and Course Work

The order of decisions · The four Parts · The decision each chapter supports · How each chapter works · Companion files · Ground rules · How to use the course

Course text from Clinical Laboratory Method Evaluation in Practice (1st ed., 2026) · Flashcards · Works offline · Version 1.1

📘 Study progress

Press ✓ Mark section complete at the end of each section after you study it. Opening the page does not mark anything. Tap a chip to jump. Labels: 🔥 key point · 📌 remember · ⚠️ common error · 💡 understand this · 🧪 at the bench · 🧠 memory aid.

About the book and this course

Front cover of Clinical Laboratory Method Evaluation in Practice

Clinical Laboratory Method Evaluation in Practice
A Case-Based Guide to Verification, Validation and Ongoing Quality Monitoring

For medical laboratory technologists, supervisors and quality teams

Hassan Shawki, Laboratory Supervisor · First edition, 2026

This free course follows the book chapter by chapter. Each course page gives the full chapter: every numbered section, worked example, table, checklist and list of common errors, followed by flashcards and original practice questions.

🔥 KEY POINT: The book follows the order in which a laboratory makes its decisions. Read the chapters in order: each one answers one decision, and the next chapter builds on it.

How the course is laid out

Course pageWhat it covers
Introduction (this page)How the book is organised, the decision each chapter supports, how each chapter works, the companion files and the book's ground rules
Chapters 0–20One page per chapter, in book order, grouped in the book's four Parts
Final AssessmentMixed practice questions across all chapters and the book's glossary (published after Chapter 20)
⚠️ Training course, not a certification. Based on the author's textbook; all examples use synthetic data. It does not replace the CLSI and ISO documents it cites, and it is not affiliated with or endorsed by CLSI or ISO.

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), title page and copyright page, pp.v–vi

How the book is organised: the order of decisions

The book follows the order in which a laboratory makes its decisions.

Part I — settles what the evidence must show, starting with Chapter 0, which makes sure the equipment itself is identified, accepted and recorded before any method is evaluated
↓
Part II — covers the quantitative studies
↓
Part III — covers qualitative tests and special settings
↓
Part IV — turns the evidence into a decision and a routine quality plan
PartTitleChaptersPrinted pages
IDeciding what the evidence must show0–51–107
IIQuantitative performance studies6–14109–282
IIIQualitative tests and special settings15–16283–325
IVFrom evidence to routine practice17–20327–410

Back matter

ItemPrinted page
Glossary411
Template A — Evaluation plan (verification or validation)421
Template B — Verification report423
Template C — Validation report425
Consolidated reference list427
Index (it uses chapter and section references)433
📌 REMEMBER the four Parts as four questions: I What must the evidence show? · II How good are the numbers? · III What about yes/no tests and special settings? · IV What do we decide, and how do we keep it working?

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), Contents, p.vii; How this book is organised, p.viii; copyright page, p.vi

Part I — Deciding what the evidence must show (Chapters 0–5)

For each chapter the book names the decision it supports and its main references.

Ch.TitleThe decision it supportsMain references
0Equipment readiness and recordsIs the analyser identified, accepted and recorded, and ready for method evaluation?ISO 15189:2022 (6.4, 8.4); CLSI EP10-Ed4, QMS13-A
1Fit for purpose: verification, validation and the life of a testDo we verify or validate, and what must we prove before the first patient result?ISO 15189:2022; ISO 9000:2015; CLSI EP19-Ed3
2The language of errorWhich kind of error are we measuring, and what does each word mean?ISO 15189:2022; CLSI EP21-Ed2, EP29-A
3The statistics an evaluator usesWhich calculation answers our question, and how sure are we of the answer?CLSI EP05-A3, EP09c-Ed3
4Setting performance specifications before testingHow much error can this test carry and still serve its intended use?EFLM Milan consensus (2015); EFLM Biological Variation Database; CLSI EP21-Ed2
5Planning the evaluationWhich studies, materials, sample sizes and criteria go into the written plan?CLSI EP19-Ed3, EP10-Ed4
💡 UNDERSTAND THIS: Part I comes before any data. The equipment is ready (Ch 0), the laboratory knows whether it verifies or validates (Ch 1), speaks one language of error (Ch 2), chooses its statistics (Ch 3), sets its specifications (Ch 4) and writes the plan (Ch 5).

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (Part I table), p.viii

Part II — Quantitative performance studies (Chapters 6–14)

Ch.TitleThe decision it supportsMain references
6PrecisionIs the random error small enough, and does it match the claim?CLSI EP05-A3, EP15-A3
7Trueness and bias against reference materialsIs the method centred on the right value?CLSI EP15-A3; EP32-R
8Method comparison with patient samplesWill patient results change when we switch methods, and by how much at each decision point?CLSI EP09c-Ed3, EP31-Ed2
9Linearity, measuring interval and dilutionOver what range can we report results directly, and when can we dilute?CLSI EP06-Ed2, EP34-Ed1
10Detection capabilityWhat is the lowest result we can report with confidence?CLSI EP17-A2
11Interference and recoveryWhich substances or sample conditions distort results, and from what level?CLSI EP07-Ed3, EP37-Ed1, C56-A
12CarryoverCan one sample or reagent contaminate the next result?CLSI EP10-Ed4, EP47-Ed1
13Reference intervalsCan we adopt the manufacturer's or a published reference interval for our population?CLSI EP28-A3c
14Combining the evidence: total error and measurement uncertaintyTaken together, is the error acceptable, and what uncertainty do we report?CLSI EP21-Ed2, EP29-A; ISO 15189:2022
🧠 MEMORY AID — the Part II studies in order: random error (6) → centring (7) → patient results across methods (8) → range (9) → low end (10) → distorting substances (11) → contamination (12) → reference intervals (13) → everything combined (14).

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (Part II table), pp.viii–ix

Parts III and IV — Qualitative tests, special settings and routine practice (Chapters 15–20)

Part III — Qualitative tests and special settings

Ch.TitleThe decision it supportsMain references
15Qualitative (binary) examinationsDoes a positive/negative test agree with the comparator well enough?CLSI EP12-Ed3
16Special settings: point-of-care, haematology, immunoassay, lot changes and multiple analysersWhat changes in the plan for these settings, and how do we keep several systems comparable?CLSI EP26-Ed2, EP31-Ed2, EP35-Ed2, EP14-Ed4

Part IV — From evidence to routine practice

Ch.TitleThe decision it supportsMain references
17Investigating unexpected resultsA study failed or looks odd: is it the method, the materials or the study?CLSI EP18-A2; the study documents above
18From validation data to a QC planWhich control rules, how many controls and how often?CLSI C24 (4th ed.), EP23-Ed2
19External quality assessment and ongoing verificationIs performance holding up once the method is in routine use?ISO 15189:2022; CLSI C24 (4th ed.), EP14-Ed4, QMS24-Ed3
20Documenting the decisionWhat goes into the report, who signs it, and what happens next?ISO 15189:2022; CLSI EP19-Ed3
💡 UNDERSTAND THIS: Part IV starts where the studies end. A failed study is investigated (17), the evidence becomes a QC plan (18), external quality assessment and ongoing checks show that performance holds (19), and the decision is documented and signed (20).

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (Part III and Part IV tables), pp.ix–x

How each chapter works, and the example that runs through the book

Every chapter follows the same pattern, so you always know where you are:

1. A question from the bench ("The question on your desk")
↓
2. One decision, worked through with a synthetic example
↓
3. A "Reading the report" feature (Chapters 6 to 20)
↓
4. Common errors
↓
5. A checklist
↓
6. References

One example, from the first page to the last

The same creatinine example runs through the book:

WhereWhat happens to the creatinine example
Chapter 0The analyser is accepted
Chapter 4The performance specifications are set
Chapters 5–19The worked examples plan, study, investigate and monitor the same creatinine method (for example Worked Examples 5.1, 6.1, 8.1, 17.1, 18.1 and 19.1)
Chapter 20The signed decision record
🧪 AT THE BENCH: Follow the creatinine example from chapter to chapter. Seeing one method go from an accepted analyser to a signed decision is the fastest way to learn how the separate studies fit together.

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised (closing paragraph), p.x; worked-example titles in the chapter outlines (Chapters 4–20)

Companion files

The worked examples, figures and exercises use synthetic data sets that readers can open and recalculate. The book describes them as a companion package:

What is in the packageDetails
Source data (CSV)For every figure and worked example that has a data set, as CSV files named after the figure or table they support (for example, Fig8.1_Fig8.2_source_data.csv for Figures 8.1 and 8.2)
Python scriptsThe scripts that generated the synthetic data sets and the QC simulations in Chapter 18, so each figure and simulated value can be reproduced, with a script (run_all.py) that runs them in the right order, since some analyses build on the output of others
Editable templatesThe equipment-record template of Chapter 0 (Table 0.7) with its event log, Templates A to C (evaluation plan, verification report and validation report) and the verification-record entry in Table 8.B as Word documents, and the follow-up register of Table 20.6 as a spreadsheet
File list (README)For each file, the chapter, table or figure it belongs to

Every file is synthetic and illustrative, like the examples it supports. The templates are starting points: a laboratory adapts them to its own procedures and criteria.

💡 In the book, the download address is given as "available from the author". On this course, every template the book prints (for example Table 0.7 in Chapter 0 and Templates A to C in Chapter 20) is shown as an HTML table you can copy.

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), Companion files, p.xi

The book's ground rules

The copyright page sets four ground rules. Keep them in mind in every chapter.

#Ground ruleWhat it means for you
1All data sets, reports and worked examples are synthetic, created for teaching.No real patient, analyser, company or laboratory is described.
2Limits, schedules and roles marked as illustrative are not recommendations for any laboratory.Do not copy an illustrative limit into your own procedure as if it were a standard.
3Laboratories must set their own criteria for their own intended use.The method of deciding transfers; the numbers belong to the example.
4ISO and CLSI documents are cited for attribution and explained in the author's own words.Consult the current editions for the full requirements and procedures. Citation does not imply endorsement by ISO, CLSI, any accreditation body or any manufacturer.
⚠️ COMMON ERROR: Treating a worked example's limit (for example a ±0.2 mmol/L comparison limit or a 1.0 µS/cm water limit in Chapter 0) as a published requirement. In the book these are illustrative local choices; your laboratory sets its own.

Source: Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), copyright page, p.vi

How to use this course

Every chapter page works the same way. Use the buttons at the top of each page:

ButtonWhat it does
Study ModeThe full chapter, section by section. Press ✓ Mark section complete after each section; the study panel shows your progress and lets you jump to any section.
FlashcardsQuick recall of the chapter's key points. Flashcards never change your quiz score.
Quiz / ExamOriginal practice questions written from the chapter. Practice mode checks each answer; exam mode shows the results after you submit.
Progress / ResultsYour study completion, score, weak areas and the questions to review.
Last-Minute ReviewThe 10-minute version of the chapter: decisions, formulas, numbers, checklist, common errors and key terms.
Export / Import ProgressA backup file of your progress for that page. When you sign in on the course hub, quiz progress also syncs between your devices.

This Introduction page has no quiz: practice questions start with Chapter 0.

Suggested rhythm for each chapter: Study Mode (one section at a time) → Flashcards → Quiz in practice mode → review wrong answers → Last-Minute Review before the next chapter
📌 Questions use new synthetic numbers, not the worked examples' numbers: you will need to reason, not remember.

Source: course guide for this site (how the pages work); book structure from Clinical Laboratory Method Evaluation in Practice (Shawki, 1st ed. 2026), How this book is organised, pp.viii–x

Training course, not a certification. Based on the author's textbook; all examples use synthetic data. It does not replace the CLSI and ISO documents it cites, and it is not affiliated with or endorsed by CLSI or ISO.

© 2026 Hassan Shawki. Course text adapted from the author's textbook Clinical Laboratory Method Evaluation in Practice.