← MedLab Study Hub
  1. MedLab Study Hub
  2. UAE Licensing Exam – MLS
  3. Sample Collection, Handling & Laboratory Errors
MLS STUDY SERIES · CLINICAL CHEMISTRY · DAY 12

Sample Collection, Handling & Laboratory Errors

The three phases of testing & where errors happen · Patient preparation (fasting, diurnal variation, posture, exercise) · Patient identification & labeling · Venipuncture technique, tourniquet & sites to avoid · Tubes, additives, serum vs plasma & order of draw · Skin puncture, arterial blood gases & special specimens · Hemolysis, lipemia & icterus · Processing, storage & stability · Hematology & coagulation specimen problems · Recognizing contamination, delta checks & post-analytical errors

Simple English · DoH Past Paper Exam → BOC6e → Harr → SUCCESS! → Other References → Additional · Works offline · questions · Version 1.3

📘 Study progress

Press ✓ Mark section complete at the end of each section after you study it. Opening the page does not mark anything. Tap a chip to jump. Labels: 🔥 very high-yield · 📌 must memorize · ⚠️ exam trap · 🧠 memory trick · 🔬 lab connection · 💡 understand this.

START HERE

1 · The three phases of testing — and where most errors happen

📚 Why this section: Calendar (Sample collection & errors) items: Preanalytical errors; Analytical errors; Postanalytical errors · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §I F Pre-analytical variables and §I G Post-analytical interpretation (p.7); Ch.11 §III B Quality assurance plan (p.372) · Check book: Clinical Laboratory Science Review, 5th ed., Laboratory Operations — Quality Assurance (p.227)

Every laboratory result passes through three phases. An error in ANY phase gives the doctor a wrong answer — even if the analyzer is perfect.

PRE-ANALYTICAL (before the test) test request → patient preparation → patient identification → collection → labeling → transport → receipt → centrifugation → storage ↓ ANALYTICAL (the test itself) calibration → QC → measurement → interference checks ↓ POST-ANALYTICAL (after the test) verification → reporting → critical-value call → interpretation → filing
🔥 VERY HIGH-YIELD — Most laboratory errors (about 60–70%) happen in the PRE-ANALYTICAL phase. The analytical phase has the FEWEST errors because QC protects it.
PhaseTypical errorsWhat protects it
Pre-analyticalWrong patient / unlabeled tube · not fasting · tourniquet too long · fist pumping · wrong tube or wrong order of draw · drawn above an IV · hemolysis · clotted or underfilled tube · delayed separation · wrong temperature or light exposureTwo patient identifiers, labeling at the bedside, written collection procedures, specimen rejection criteria, training of phlebotomists
AnalyticalFailed calibration · QC out of control · reagent problems · interference (hemolysis, lipemia, icterus) · above linearity (hook effect, need dilution)Internal QC (Levey-Jennings, Westgard), proficiency testing / EQA, maintenance
Post-analyticalTranscription error · result sent to the wrong chart · critical value not called · wrong units or reference interval · long turnaround time (TAT)LIS interfacing, auto-verification, delta checks, critical-value policy, TAT monitoring
⚠️ EXAM TRAP — Quality control (QC) checks only the ANALYTICAL phase. Normal QC does NOT prove the specimen was collected correctly. A hemolyzed or IV-contaminated sample gives a wrong result even when both controls are in range.
🧠 MEMORY TRICK — "PRE = PROBLEMS": the phase BEFORE the analyzer causes most problems.

📚 Book check — added from the two review books

  • Inappropriate specimen type and mislabeled specimens are the MOST COMMON pre-analytical problems the laboratory sees. (Hubbard Ch.1, p.7)
  • Quality Assurance (QA) covers ALL three phases: pre-analytical (specimen collection, transport, preservatives), analytical (test processing — QC data are used here) and post-analytical (how results are reported and acted upon). QC is only the analytical part of QA. (6.0 p.227; Hubbard Ch.11, p.372)
  • The written procedure manual must give, for each test: criteria for specimen collection, processing and rejection; interfering substances and common sources of error; and result reporting, including panic (critical) values. (Hubbard Ch.11, pp.375–376)

📚 How the sections were chosen

Two sources: the fixed calendar list for this day and the chapter headings of A Concise Review of Clinical Laboratory Science (Hubbard). Check book: Clinical Laboratory Science Review, 5th ed. (6.0).

#Study sectionCalendar items it coversBook heading (Hubbard, page)
1The 3 phases & where errors happenPreanalytical / analytical / postanalytical errorsCh.1 §I F–G (p.7); Ch.11 §III B (p.372)
2Patient preparation & biological variablesPatient preparation; Fasting; TimingCh.11 §III B (p.372)
3Patient identification & labelingPreanalytical errors (identification)Ch.1 §I F (p.7)
4Venipuncture techniqueTourniquet effects; ContaminationCh.1 §I F 1 (p.7)
5Tubes, additives & order of drawOrder of draw; Tube additives; Serum vs plasma; Wrong anticoagulantCh.1 §I F 1a (p.7)
6Capillary, arterial & special specimensTube additives; Storage; StabilityCh.1 §IV C 5a (p.19); §IV I 3 (p.27)
7Hemolysis, lipemia & icterus (HIL)Hemolysis; Lipemia; Icterus; InterferencesCh.1 §IV A 9 (p.16); §V (pp.32–34)
8Processing, storage & stabilitySample storage; Stability; Delayed separationCh.1 §I F 2 (p.7)
9Hematology & coagulation specimen problemsImproper fill; Wrong anticoagulantCh.3 §I A (p.87)
10Recognizing & handling specimen errorsAnalytical / postanalytical errors; TroubleshootingCh.11 §IV A (pp.375–376)
11Top exam trapsCommon examination troubleshootingCh.1 §I F (p.7)

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.5 Preanalytical Variation and Pre-Examination Processes (pp.80–82); SUCCESS! in Clinical Laboratory Science, Ch.13, Q25, Q38 (pp.1011, 1013) and Ch.11, Q14 (p.937); Medical Laboratory Science Review (Harr), Ch.5, p.236, Q52.

📌 MUST MEMORIZE

2 · Patient preparation and biological (physiological) variables

📚 Why this section: Calendar (Sample collection & errors) items: Patient preparation; Fasting; Timing · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.11 §III B Quality assurance plan — patient preparation follows written guidelines (p.372) · Check book: Clinical Laboratory Science Review, 5th ed., Chemistry — Lipid specimen collection and handling (p.105); Cortisol diurnal variation (p.130)

Some changes are REAL changes inside the patient's body (not lab mistakes). We control them by standardizing how the patient is prepared, so the result can be compared with the reference interval.

Fasting

TestPreparationWhy
Fasting plasma glucoseNo food or drink except water for at least 8 hFood raises glucose
Triglycerides / calculated LDLTraditionally 12 h fast (10–14 h)Chylomicrons after a meal raise TG for hours; Friedewald LDL needs fasting TG
Total cholesterol & HDLFasting not essentialLeast affected by a recent meal (Harr, p.259, Q57)
Oral Glucose Tolerance Test (OGTT)Normal diet with ≥150 g carbohydrate/day for 3 days, then 8–14 h overnight fast; no smoking, coffee, or exercise during the test; seatedCarbohydrate restriction before the test gives a FALSELY ABNORMAL (diabetic-looking) curve
AmmoniaFasting; no smoking for 8 hTobacco smoke can double ammonia
⚠️ EXAM TRAP — A mixed meal increases glucose, triglycerides, inorganic phosphate, ALP (intestinal) (a pure carbohydrate load or glucose infusion instead lowers phosphate). A delta-check flag on phosphate + glucose + TG + ALP together = the patient was not fasting (Harr, p.323, Q46).

Time of day (diurnal / circadian variation)

Cortisol & ACTH → HIGHEST in the early MORNING (≈8 a.m.), LOWEST late evening/midnight Iron → higher in the morning Potassium → lower in the afternoon than in the morning Growth hormone, prolactin → rise during sleep Therapeutic drugs → TIMING relative to the dose matters (peak vs trough)

Posture

Lying (supine) → standing (upright) ↓ Water moves from blood into the tissues ↓ Plasma volume ↓ (about 10%) ↓ LARGE molecules and protein-bound substances become MORE concentrated (proteins, albumin, enzymes, lipids, total calcium, cells, Hct) Small free ions (Na⁺, K⁺, glucose) change very little

Total calcium rises about 5–10% from supine to upright; ionized calcium does not change. Aldosterone, renin and plasma metanephrines need the patient supine for at least 30 minutes before collection.

Other patient factors

  • Exercise / muscle activity → ↑ CK, AST, LD, myoglobin, K⁺, lactate. Even fist clenching during venipuncture raises K⁺.
  • Stress, anxiety → ↑ cortisol, catecholamines, glucose, WBC. Catecholamines: patient resting supine 30 min; medications stopped if possible.
  • Smoking → ↑ carboxyhemoglobin, ↑ cortisol, ↑ glucose, ↑ ammonia, ↑ Hb/Hct.
  • Alcohol → ↑ GGT, ↑ triglycerides, ↑ uric acid, ↑ MCV.
  • Cooked meat → ↑ creatinine up to about 20%.
  • Drugs → in vivo effects (e.g., diuretics lower K⁺) and in vitro interference (e.g., ascorbic acid lowers peroxidase-based glucose).
  • Age, sex, pregnancy → unmodifiable; they are handled by correct reference intervals (e.g., ALP high in growing children and in pregnancy — placental ALP).
🔬 LAB CONNECTION — Request forms and the LIS should record the collection time, fasting status and, for drugs, the time of the last dose. Without them the result cannot be interpreted.

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4 (p.62) and Ch.5 (pp.81–88); Medical Laboratory Science Review (Harr), Ch.5, p.206 Q7, p.244 Q31, p.259 Q57, p.290 Q36, p.323 Q46; DoH Past Paper Exam — Chemistry, p.10, Q72.

🔥 VERY HIGH-YIELD

3 · Patient identification and specimen labeling

📚 Why this section: Calendar (Sample collection & errors) items: Preanalytical errors (patient identification, labeling) · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §I F Pre-analytical variables — two identifiers, mislabeled specimens (p.7) · Check book: Clinical Laboratory Science Review, 5th ed., Immunohematology — Pretransfusion testing, sample requirements (p.20)

A perfect result on the wrong patient is the most dangerous laboratory error — especially in blood bank (wrong blood in tube → ABO-incompatible transfusion).

1. Ask the patient to STATE full name + date of birth (open question — never "Are you Mr X?") ↓ 2. Compare with the wristband (inpatient) and the request form — at least TWO identifiers ↓ 3. Collect the specimen ↓ 4. LABEL the tubes AT THE BEDSIDE, in front of the patient, AFTER the draw ↓ 5. Label: full name, unique ID number (MRN), date & time of collection, collector's initials/ID
🔥 TWO identifiers (e.g., name + date of birth or MRN). Room number or bed number is NEVER an identifier.
SituationCorrect action
Unlabeled or mislabeled specimenReject and request a new specimen. The lab never labels a tube for someone else from "information provided".
Unlabeled blood bank (pre-transfusion) sample brought by a doctorDiscard and request a new, properly labeled sample (SUCCESS!, p.565, Q142)
Irreplaceable specimen (CSF, tissue) mislabeledFollow policy: the collector comes to the lab, identifies and signs; result is reported with a comment
Patient refuses venipunctureDo NOT draw. Respect the refusal, notify the nurse/physician/supervisor and document (Harr, p.535, Q63)
Patient asleep / unconsciousWake gently; identify by wristband; never draw without identification
⚠️ EXAM TRAP — Pre-labeling tubes BEFORE collection is not acceptable: tubes can be used on the wrong patient. Blood bank tube labels must also carry the date of phlebotomy and an identifier of the phlebotomist (SUCCESS!, p.565, Q143).
🧠 MEMORY TRICK — "2 IDs, 0 rooms, label at the bed."

📚 Book check — added from the two review books

  • Blood bank sample: the patient is identified with 2 unique identifiers, and the lab must be able to identify the phlebotomist and the date of collection. For the 3-day rule, the day of draw = day 0. Keep the patient sample and a donor RBC segment for 7 days after transfusion. (6.0 p.20)

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4 (pp.61, 67, 76); SUCCESS! in Clinical Laboratory Science, Ch.5, Q142–Q144 (p.565); Medical Laboratory Science Review (Harr), Ch.9, p.532 Q46 and p.535 Q63.

📌 MUST MEMORIZE

4 · Venipuncture technique — step by step

📚 Why this section: Calendar (Sample collection & errors) items: Tourniquet effects; Contamination · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §I F 1 Specimen collection (p.7) · Check book: Clinical Laboratory Science Review, 5th ed., Chemistry — Potassium specimen collection and handling (p.114)

Identify patient (2 IDs) → check request & fasting → hand hygiene, gloves ↓ Patient seated or lying; arm straight; choose site (median cubital vein first → cephalic → basilic) ↓ Tourniquet 7–10 cm (3–4 in) above site — NOT longer than 1 minute ↓ Clean with 70% isopropyl alcohol (concentric) → let it AIR-DRY ↓ Anchor vein, needle BEVEL UP, angle 15–30° ↓ Release tourniquet as soon as blood flows ↓ Fill tubes in the correct ORDER OF DRAW; invert gently (do not shake) ↓ Remove needle → activate safety device → pressure (do not bend the arm) ↓ LABEL at the bedside

Tourniquet and fist pumping

Tourniquet > 1 minute (hemoconcentration / venous stasis) ↓ Water and small molecules leave the vein → large molecules stay ↓ ↑ total protein, albumin, enzymes, lipids, total calcium, cells, iron ↑ lactate & ↑ ammonia (stasis, anaerobic metabolism) ↓ pH ↑ K⁺ (especially with FIST PUMPING — K⁺ released from muscle; can rise 1–2 mmol/L)
🔥 DoH-STYLE — "Using a tourniquet for a long time when collecting lactic acid" → falsely increased lactate. For lactate, avoid the tourniquet or release it immediately, and place the sample on ice.

Sites to avoid

  • Arm with an IV infusion — use the other arm. If both arms have IVs: draw BELOW the IV after the infusion has been stopped for at least 2 minutes (Tietz: ≥3 min, with clinician consent); discard the first 5 mL; document "drawn below IV".
  • Same side as a mastectomy (lymphostasis) · arteriovenous fistula/graft · hematoma · scarred, burned or edematous areas.
  • Drawing from a line (catheter): flush, then withdraw a discard volume (≈ 2× dead space, adults about 5–10 mL) before the sample; coagulation tests from a heparinized line may show heparin contamination.

Complications and fixes

ProblemCause / fix
HematomaNeedle through both walls, partial insertion, or not enough pressure after removal
HemolysisSmall needle (>23 G), wet alcohol, forcing blood through a syringe needle, vigorous shaking, traumatic draw
No blood flowBevel against vein wall → rotate/adjust needle slightly; lost vacuum → new tube
Fainting (syncope)Stop, remove tourniquet and needle, lower the head, call for help
Accidental arterial punctureBright red pulsing blood → remove, firm pressure ≥5 min
🔬 LAB CONNECTION — Butterfly (winged) set + a light-blue (citrate) tube as the FIRST or ONLY tube → draw a discard tube first. The tubing air space would otherwise underfill the citrate tube (wrong 9:1 ratio).

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4 (pp.62–67, 71) and Ch.5 (pp.87–88, MCQ 8 p.128.e16); Clinical Hematology: Theory and Procedures, 5th ed. (Turgeon), Ch.2 Principles of Blood Collection (review questions p.47); Medical Laboratory Science Review (Harr), Ch.5, p.244 Q31; DoH Past Paper Exam — Chemistry, p.7, Q2.

🔥 VERY HIGH-YIELD

5 · Tubes, additives, serum vs plasma, and order of draw

📚 Why this section: Calendar (Sample collection & errors) items: Order of draw concepts; Tube additives; Serum vs plasma; Wrong anticoagulant · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §I F 1a Evacuated blood tubes — order of draw (p.7) · Check book: Clinical Laboratory Science Review, 5th ed., Chemistry — Sample collection and handling (p.101); Coagulation — Specimen collection/handling (p.74); Hematology — Anticoagulants (p.55)

Serum = liquid left AFTER the blood clots (no fibrinogen, no clotting factors). Plasma = liquid from blood that did NOT clot because an anticoagulant was added (contains fibrinogen).

🧠 "Serum is plasma without fibrinogen." Serum needs ≥30 minutes to clot before centrifugation (longer in patients on anticoagulants).
StopperAdditiveHow it worksMain useDo NOT use for
Yellow / culture bottleSPS (sodium polyanethol sulfonate) or ACDSPS: anticoagulant + inhibits complement and phagocytosisBlood culture (SPS); ACD for HLA/DNAChemistry
Light blue3.2% sodium citrate, ratio 9 blood : 1 citrateBinds calcium (reversible — calcium added back in the test)PT, aPTT, fibrinogen, D-dimer, factor assaysChemistry (dilutes, binds Ca)
BlackSodium citrate 1:4Binds calciumWestergren ESR—
Red / gold (SST) / tigerNone or clot activator ± gelClots → serum; gel separates serum from cellsChemistry, serology, immunology, blood bank (red)Tests needing whole blood/plasma
GreenLithium or sodium heparin ± gel (PST)Activates antithrombin → inhibits thrombin (and Xa)STAT chemistry plasma, ammonia, blood gases (syringe), ionized Ca, K⁺ confirmationCoagulation; CBC/smears (blue background, clumping); lithium levels (Li-heparin); PCR (inhibits)
Lavender / purple (pink = blood bank)K₂EDTA (or K₃EDTA)Chelates calcium irreversiblyCBC, blood smear, HbA1c, ESR (ICSH method), blood bank (pink), cyclosporine/tacrolimus, molecularCalcium, K⁺, ALP, Mg, coagulation, iron
GraySodium fluoride + potassium oxalateFluoride inhibits enolase (glycolysis); oxalate precipitates CaGlucose, lactate, blood alcoholBUN by urease (fluoride inhibits urease), many enzymes, electrolytes (Na/K salts)
Royal (navy) blueNone or EDTA; trace-element freeCertified free of metalsTrace metals (zinc, copper, selenium), toxicology—
TanK₂EDTA, lead freeCertified <0.25 µg/dL leadBlood lead (whole blood)—

Order of draw (venipuncture, CLSI)

1. Blood culture (sterile) ← sterile FIRST (prevents contamination) 2. LIGHT BLUE citrate ← coagulation 3. RED / GOLD serum (± clot activator, gel) 4. GREEN heparin (± gel) 5. LAVENDER / PINK EDTA 6. GRAY fluoride–oxalate ← strongest "contaminators" LAST
🧠 MEMORY TRICK — "Bottles Before Red Goes Last Gray" or the phrase "Stop Light Red, Stay Put, Green Light Go": Sterile · Light blue · Red · SST · PST(green) · Green · Lavender · Gray.

Why the order matters — additive carry-over

Wrong order / contaminationResult
K-EDTA into a serum/heparin tubeK⁺ falsely HIGH; Ca²⁺, Mg²⁺ falsely LOW; ALP falsely LOW (Mg/Zn cofactors chelated). Classic pattern: very high K⁺ + very low Ca²⁺ in a well patient.
Clot activator / serum tube BEFORE citrateActivates coagulation → shortened PT/aPTT
Heparin into citrate tubeProlonged aPTT, thrombin time
Fluoride/oxalate into other tubes↑ Na⁺/K⁺, ↓ Ca²⁺, inhibited enzymes (ALP, amylase, urease)
Citrate into chemistry tube↑ Na⁺, ↓ Ca²⁺, dilution
⚠️ EXAM TRAPS — (1) "Which test can't you do on EDTA?" → Calcium. (2) "Gray tube sent for BUN by urease?" → cannot be done (fluoride inhibits urease). (3) "Lithium 14 mmol/L, patient well" → sample collected in a lithium-heparin tube. (4) "K⁺ 9.5, Ca 3.0 mg/dL, patient stable" → EDTA contamination → recollect.

📚 Book check — added from the two review books

  • Serum (red top) is used for most chemistry tests. When plasma is needed, heparin is better than oxalate, EDTA or citrate (these add Na⁺/K⁺ or bind calcium). (6.0 p.101)
  • Plasma sent by mistake for serum protein electrophoresis → an extra fibrinogen band between β and γ (near the application point) that can look like a monoclonal band → recollect serum and repeat. (6.0 p.107; Hubbard Ch.1, p.16)
  • With a straight needle and evacuated tubes, the light-blue (citrate) tube may be drawn FIRST — old fears of tissue-thromboplastin contamination are unfounded. (A discard tube is needed only with a butterfly set — see Section 4.) (6.0 p.74)

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4, Table 4.2 (p.65), pp.69–71 and MCQ 3, 5 (p.79.e2); Clinical Hematology: Theory and Procedures, 5th ed. (Turgeon), Ch.2 (p.47); SUCCESS! in Clinical Laboratory Science, Ch.13, Q4, Q14, Q15 (pp.1009–1010) and Ch.1, Q154 (p.111); Medical Laboratory Science Review (Harr), Ch.2, p.44 Q3–Q4; Ch.5, p.303 Q38, p.313 Q16; DoH Past Paper Exam — Chemistry, p.12 Q94, p.23 Q97; DoH Past Paper Exam — Hematology/Blood Bank, p.5 Q64, p.14 Q88.

📌 MUST MEMORIZE

6 · Skin puncture, arterial blood gases and special specimens

📚 Why this section: Calendar (Sample collection & errors) items: Tube additives; Sample storage; Sample stability (special specimens) · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §IV C 5a Specimen requirements for blood gas analysis (p.19) and §IV I 3 Porphyrin specimens (p.27) · Check book: Clinical Laboratory Science Review, 5th ed., Chemistry — Glucose specimens (p.101); ACP specimen handling (p.111); Ammonia (pp.127, 135)

Skin (capillary) puncture

  • Infants (<1 year): heel — medial or lateral plantar surface. Never the posterior curve, the arch, or an old puncture site. Depth <2.0 mm (avoid bone → osteomyelitis).
  • Older children and adults: finger — palmar surface of the distal segment of the middle or ring finger, across the fingerprint.
  • Warm the site (≈42 °C, 3–5 min) — especially for capillary blood gases ("arterialized" blood).
  • Alcohol must dry · wipe away the FIRST drop (tissue fluid, alcohol) · do NOT squeeze hard ("milking" adds tissue fluid and hemolysis) · avoid air bubbles.
ORDER OF DRAW — SKIN PUNCTURE (different from venipuncture!) 1. Blood gases (capillary tube) 2. EDTA (lavender) ← FIRST tube: platelets clump quickly in a skin puncture 3. Other anticoagulant tubes (heparin, fluoride) 4. Serum tubes LAST
⚠️ EXAM TRAP — Capillary blood differs from venous blood: glucose is HIGHER in capillary blood (largest clinically important difference; K⁺ is also slightly higher). Capillary total protein, calcium, bilirubin, sodium and chloride are slightly LOWER; phosphate and urea show no difference (Tietz Table 4.7). Capillary specimens are unsuitable when circulation is poor (shock, dehydration).

Arterial blood gases (ABG)

Syringe with dry (lyophilized) HEPARIN (never EDTA, citrate or oxalate — they change pH) ↓ Remove ALL air bubbles immediately, cap the syringe (anaerobic) ↓ Mix (roll) to dissolve heparin ↓ Analyze within 30 minutes (plastic syringe at ROOM TEMPERATURE) or glass syringe in ice water if delay is expected
ErrorpHPCO₂PO₂Why
Air bubble / exposure to air↑↓↑ (toward ≈150 mm Hg)Room air has almost no CO₂ and more O₂
Delay at room temperature↓↑↓Living cells (WBCs, platelets, reticulocytes) consume O₂, make CO₂ and lactic acid
Excess liquid heparin↓ (slightly)↓ (dilution)shifts toward ≈150 (a low PO₂ rises)Dilution with heparin that is in equilibrium with room air

Before radial artery puncture, perform the modified Allen test to check ulnar collateral circulation.

Specimens that need special handling

AnalyteSpecial handlingWhat goes wrong
AmmoniaHeparin/EDTA plasma, full tube, on ice, separate and test within 30 min; no smoking; minimal stasisDelay, stasis → ammonia ↑ (deamination of amino acids)
Lactate, pyruvateFluoride/oxalate (gray) on ice; no fist clenching; tourniquet released earlyGlycolysis → lactate ↑
Ionized calciumAnaerobic (no air), heparinized whole blood (balanced/low heparin), on ice, test within 2 h; serum only if kept cappedLoss of CO₂ → pH ↑ → iCa ↓. EDTA, citrate, oxalate chelate Ca.
Bilirubin, carotene, porphyrins, vitamin A, B₆, methotrexateProtect from LIGHT (amber tube or foil)Photodegradation → falsely LOW bilirubin (up to ~50% per hour in direct light)
ACTH, PTH, gastrin, catecholaminesEDTA (lavender) on ice, rapid separation (refrigerated centrifuge)Protease degradation → falsely low
Renin (exception!)EDTA at ROOM temperature, centrifuge at room temperature, then freeze plasmaChilling causes cryoactivation of prorenin → falsely HIGH renin
Cold agglutinins, cryoglobulinsKeep at 37 °C until serum is separatedAntibody binds to cells in the cold → falsely low
LeadWhole blood (tan/royal blue EDTA); venous preferredLead is in RBCs; finger skin can contaminate
Carbon monoxide (COHb)Whole blood (heparin/EDTA)CO is bound to hemoglobin in RBCs
Trace metalsRoyal (navy) blue tubeOrdinary stoppers contain zinc etc.
Blood cultureDisinfect skin (chlorhexidine/iodine), clean bottle tops, drawn FIRST; 2 setsSkin contaminants (CoNS)

📚 Book check — added from the two review books

  • Acid phosphatase (ACP) loses activity at room temperature → separate serum from cells quickly and stabilize it (add disodium citrate monohydrate, or lower the pH to about 5.4 with acetic acid). Hemolysis gives falsely ↑ ACP (RBCs contain ACP); fluoride, oxalate and heparin give falsely ↓ ACP. (6.0 p.111; Hubbard Ch.1, p.32)
  • Ammonia: a clotted (serum) sample is the wrong specimen — use heparin plasma on ice, centrifuge and test at once. Delays longer than 15 minutes can raise ammonia even on ice (amino acids/nitrogen compounds break down to ammonia). (6.0 pp.127, 135)
  • Arterial and capillary glucose are about 2–3 mg/dL higher than venous glucose. (6.0 p.101)
  • Urine porphyrins: protect from light — levels can fall by up to 50% in 24 h in light. Best specimen: fresh early-morning urine (10–20 mL) with no preservative. (Hubbard Ch.1, p.27)

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4 (pp.67–71, 76–77) and MCQ 7, 9 (p.79.e2); Medical Laboratory Science Review (Harr), Ch.5, p.193 Q17, p.200 Q53, p.244 Q31, p.303 Q38, p.316 Q28; SUCCESS! in Clinical Laboratory Science, Ch.1, Q333–Q335 (p.133), Q403, Q405 (p.141); Clinical Hematology: Theory and Procedures, 5th ed. (Turgeon), Ch.2 (p.47); DoH Past Paper Exam — Chemistry, p.10 Q69, p.15 Q37.

🔥 VERY HIGH-YIELD

7 · Hemolysis, lipemia and icterus — the "HIL" interferences

📚 Why this section: Calendar (Sample collection & errors) items: Hemolysis; Lipemia; Icterus; Interferences · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §IV A 9 Protein analysis — artifacts (p.16) and §V Enzymology — specimen errors (pp.32–34) · Check book: Clinical Laboratory Science Review, 5th ed., Chemistry — Hemolysis 'KLAMP' (p.101); Potassium (p.114); Bilirubin specimen handling (p.123)

Hemolysis (pink/red serum)

Hemolysis = red cells break and release their contents. In vitro hemolysis (during collection/handling) is far more common than true in vivo hemolysis.

Red cells burst ↓ three ways to cause error 1. RELEASE of substances that are HIGHER inside RBCs than in plasma → ↑ K⁺, LD, AST, ALT, ACP, phosphate, Mg²⁺, iron, ammonia 2. SPECTRAL (optical) interference — Hb absorbs at ≈415, 540, 570 nm 3. CHEMICAL interference / DILUTION → Hb inhibits the diazo reaction: bilirubin (Jendrassik–Grof) falsely ↓ → RBC fluid dilutes Na⁺, Cl⁻, glucose (slightly ↓)
Hemolysis effectAnalytes
Greatly ↑ (do NOT report)K⁺ (≈25× higher in RBCs), LD (≈150×), AST (≈40×), acid phosphatase, phosphate, Mg²⁺, iron, free Hb
Slight changeALT, CK (adenylate kinase interference only when marked), total protein (↑)
Little / no effectNa⁺, calcium (least affected electrolyte), glucose, urea, creatinine (method-dependent)
Falsely ↓Bilirubin (diazo inhibition), insulin (degraded by RBC proteases), troponin T in some assays
🔥 DoH-STYLE — "Sample received with a high K⁺. What will you do?" → Check the sample for hemolysis (and clotting, EDTA contamination, delayed separation, wrong anticoagulant) → recollect. Never report a K⁺ from a visibly hemolyzed sample.
⚠️ EXAM TRAP — Pseudohyperkalemia (K⁺ high in serum only): hemolysis, fist clenching, delayed separation, refrigeration of whole blood, EDTA contamination, and very high platelets or WBCs (thrombocytosis, myeloproliferative neoplasm, leukemia) — K⁺ leaks from platelets during CLOTTING. Confirm with heparinized plasma (no clotting → normal K⁺).

Lipemia (milky serum)

High triglycerides (chylomicrons, VLDL) — after a meal, hypertriglyceridemia, lipid infusion ↓ 1. LIGHT SCATTERING (turbidity) → photometric errors (↑ or ↓, method-dependent) 2. VOLUME DISPLACEMENT → indirect ISE Na⁺, K⁺, Cl⁻ falsely ↓ (pseudohyponatremia) 3. Non-homogeneous sample (lipid layer on top) 4. Hematology: falsely ↑ Hb → falsely ↑ MCH and MCHC
  • Pseudohyponatremia: indirect ISE (diluted) reads low; direct ISE (undiluted, blood gas analyzer) gives the true Na⁺ → report the direct ISE result.
  • Remove lipids by ultracentrifugation (preferred) or high-speed centrifugation/lipid-clearing agents — but measure triglycerides and lipid-soluble drugs on the NATIVE sample BEFORE delipidation.
  • CBC: correct the Hb with a plasma blank or saline replacement: Corrected Hb = Whole-blood Hb − [Plasma Hb × (1 − Hct/100)].
  • Optical coagulation analyzers cannot detect the clot in grossly lipemic plasma → use an electromechanical (mechanical) clot detection method.

Icterus (dark yellow serum)

High bilirubin absorbs strongly at 400–540 nm. It causes spectral interference and chemical interference with peroxidase (Trinder) reactions (bilirubin reacts with H₂O₂) → falsely LOW cholesterol, triglycerides, uric acid, creatinine (enzymatic) in some methods.

🔬 LAB CONNECTION — Modern analyzers measure HIL indices (serum indices) automatically. Each test has a cut-off above which the result is suppressed or reported with a comment. Sample blanking (sample + diluent, no color reagent; or saline in place of reagent) corrects only for the sample's own color — it does NOT correct chemical interference or released analytes.
🧠 MEMORY TRICK — Hemolysis raises what lives INSIDE the RBC: "K-LAMP" = K⁺, LD, AST (and ACP), Mg, Phosphate.

📚 Book check — added from the two review books

  • 6.0 memory aid: hemolysis — "help (c)KLAMP the leak": K⁺, LD, Aldolase and ACP, Mg²⁺, PO₄ all falsely ↑. Free hemoglobin also raises iron; bilirubin may be ↓ or ↑ depending on the hemoglobin and bilirubin levels (and the method). (6.0 pp.101, 135)
  • Hemolysis artifacts on electrophoresis: SPE → an extra heavy β band (free Hb); LD isoenzymes → LD1 > LD2 "flipped" pattern that mimics myocardial infarction. (6.0 p.101; Hubbard Ch.1, pp.16, 34)
  • Pseudohyperkalemia numbers: WBC ≥ 500,000/µL or platelets ≥ 700,000/µL; also excessive heel or finger squeezing in skin punctures. Normally plasma (and whole-blood) K⁺ is 0.1–0.7 mmol/L LOWER than serum K⁺, because platelets release K⁺ during clotting. (6.0 p.114)
  • Lipemia gives falsely ↑ bilirubin. A non-fasting sample left in the refrigerator shows a creamy chylomicron layer on top of turbid serum (abnormal in a fasting sample). (6.0 pp.105, 123)

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4 (pp.71–72) and Ch.5 (pp.89–100; MCQ 2–6, p.128.e16); Medical Laboratory Science Review (Harr), Ch.1 p.37 Q12; Ch.5 p.176 Q18, p.201 Q56, p.212 Q27, p.220 Q64, p.265 Q17, p.310 Q3, p.316 Q29; SUCCESS! in Clinical Laboratory Science, Ch.2, Q242, Q259–Q260 (pp.313–315); BOC Study Guide, 6th ed., Ch.4, Q278–Q279, Q296 (pp.264–267); DoH Past Paper Exam — Chemistry, p.1 Q10, p.11 Q76, p.12 Q98; DoH Past Paper Exam — Hematology/Blood Bank, p.9 Q27.

🔥 VERY HIGH-YIELD

8 · Specimen processing, transport, storage and stability

📚 Why this section: Calendar (Sample collection & errors) items: Sample storage; Sample stability; Delayed separation · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §I F 2 Specimen transport and storage (p.7) · Check book: Clinical Laboratory Science Review, 5th ed., Chemistry — Glucose specimen collection and handling (p.101); Potassium (p.114)

Delayed separation of serum/plasma from cells

Whole blood left unspun at ROOM TEMPERATURE ↓ cells keep living (glycolysis) and leak GLUCOSE ↓ about 5–7% per hour (≈10 mg/dL per hour) — faster with high WBC or platelets, neonates LACTATE ↑, AMMONIA ↑, pH ↓, PCO₂ ↑, PO₂ ↓ K⁺ ↑, PHOSPHATE ↑ (leak from cells; phosphate esters hydrolysed) LD ↑, AST ↑ (leak) Bilirubin ↓ if exposed to light
🔥 RULE — Separate serum/plasma from cells as soon as possible, within 2 hours of collection. Sodium fluoride (gray) preserves glucose, but fluoride works only after ≈1–2 h (it blocks enolase, a late glycolysis step) → place on ice or separate quickly.

Refrigerating WHOLE blood (unseparated)

Whole blood in the fridge (4 °C) ↓ Na⁺/K⁺-ATPase pump in RBC membrane stops working (it needs warmth) ↓ K⁺ leaks OUT of red cells ↓ K⁺ falsely ↑ (even without visible hemolysis)
⚠️ EXAM TRAP — DoH: "Blood sample stored overnight before sent to the lab → which are falsely high?" → Potassium and phosphate. "Sample of blood more than 2 hours → what decreases?" → Glucose (and bilirubin if exposed to light).

Coagulation specimen stability

TestStability (capped, uncentrifuged or centrifuged)What goes wrong
PTUp to 24 h at room temperatureRefrigeration → cold activation of factor VII → PT falsely SHORT
aPTT (no heparin)4 h (room temperature or 2–4 °C)Labile factors V and VIII decay → aPTT falsely LONG → request a new sample
aPTT/anti-Xa on heparinCentrifuge within 1 hPlatelets release PF4 → neutralizes heparin → aPTT falsely short
Platelet-poor plasmaPlatelets <10 × 10⁹/L (double centrifugation for lupus anticoagulant)Residual platelets neutralize phospholipid-dependent tests

Hematology specimen stability (EDTA)

  • CBC best within 6 h; most parameters stable 24 h at room temperature.
  • Standing at room temperature 6–24 h → RBCs swell: MCV ↑, Hct ↑, MCHC ↓; ESR ↓; WBC morphology changes (vacuoles, crenated cells). Make smears as soon as possible — ideally within 1 h (Turgeon) and no later than about 5 h (SUCCESS!), before neutrophils vacuolate and cells crenate.
  • Platelet count stable about 24 h; ESR should be set up within 4 h (24 h at 4 °C).

Other stability facts

  • CSF: deliver and test immediately (glucose falls; cells lyse; bacteria die). Do NOT refrigerate the microbiology tube.
  • Light-sensitive: bilirubin, porphyrins, vitamin A, β-carotene, B₆ → amber tube/foil.
  • Never freeze whole blood (hemolysis). Avoid repeated freeze–thaw; freezing destroys LD-5 (LD-4/5 cold labile).
  • Serum for CK: stable ≈4 h at room temperature and a week at 4 °C; CK is NOT in RBCs, so slight hemolysis does not interfere. Calcium chelators (citrate, EDTA) remove Mg²⁺ needed by CK → do not use.
  • Add-on tests: allowed only if the original specimen is the correct type, has enough volume, was stored correctly and is within the analyte's stability time.
  • Transport: upright, capped (prevents evaporation, CO₂ loss, aerosols); pneumatic tubes with sudden stops can cause hemolysis.
  • Centrifuge: balanced, lid closed until the rotor stops; speed checked with a tachometer; serum tubes clotted ≥30 min first.

📚 Book check — added from the two review books

  • Glucose falls about 10 mg/dL per hour (≈7%) in whole blood, but refrigerated, separated serum is fairly stable for glucose. (6.0 p.101)

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4 (pp.70, 76–78; MCQ 10, p.79.e2) and Ch.5 (p.81); Medical Laboratory Science Review (Harr), Ch.2 p.46 Q20, p.68 Q9, p.72 Q16; Ch.5 p.265 Q17, p.267 Q22, p.316 Q28; SUCCESS! in Clinical Laboratory Science, Ch.1, Q149, Q175 (pp.111–113), Ch.3, Q59 (p.403), Ch.17, Q9 (p.1105); BOC Study Guide, 6th ed., Ch.4, Q290 (p.266); DoH Past Paper Exam — Chemistry, p.3 Q44, p.6 Q86, p.20 Q80.

📌 MUST MEMORIZE

9 · Hematology and coagulation specimen problems

📚 Why this section: Calendar (Sample collection & errors) items: Improper fill; Wrong anticoagulant (hematology and coagulation) · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.3 §I A Electronic cell counting — common errors (p.87) · Check book: Clinical Laboratory Science Review, 5th ed., Hematology — Hemoglobin, hematocrit and ESR sources of error (pp.55, 60, 70); Coagulation — Specimen collection/handling (p.74); Laboratory Operations — Erroneous CBC results (p.240)

Citrate tube: the 9 : 1 rule

Correct tube: 9 parts blood + 1 part 3.2% citrate (fill ≥90%) ↓ citrate binds just enough calcium; the test adds calcium back UNDERFILLED tube (e.g., 3 mL in a 4.5 mL tube) ↓ too much citrate for the plasma excess citrate binds the reagent calcium ↓ PT and aPTT falsely PROLONGED → REJECT (QNS) and recollect
🔥 HIGH HEMATOCRIT (>55%, polycythemia, neonates): little plasma → same problem as underfilling (PT/aPTT falsely long). Fix: REDUCE the citrate volume:
C (mL citrate) = 0.00185 × V (mL blood) × (100 − Hct)
Example: Hct 70%, 4.5 mL blood → C = 0.00185 × 4.5 × 30 ≈ 0.25 mL citrate (instead of 0.5 mL).
  • Clotted citrate sample → factors consumed → prolonged PT/aPTT (or shortened if partially activated) → check every coagulation tube for clots; reject.
  • Hemolyzed coagulation sample → reject (activation of factors and platelets; optical interference).
  • Heparin contamination (drawn from a heparinized line) → aPTT and thrombin time very long, PT nearly normal → reptilase time normal; perform heparin neutralization or recollect by venipuncture.
  • Coagulation tests need platelet-poor plasma: centrifuge ≈1500 g for 15 min.

EDTA problems in the CBC

ProblemEffectFix
Underfilled EDTA tube (excess EDTA)RBCs shrink → Hct ↓, MCV ↓ (MCHC ↑); counts and Hb unchangedRecollect with correct fill
EDTA-dependent platelet clumping / platelet satellitismPlatelet count falsely LOW; WBC may be falsely high; clumps or platelets ringing neutrophils on the smearRecollect in sodium citrate; multiply the platelet count by 1.1 (dilution correction)
Cold agglutininRBC count ↓, MCV ↑, MCHC ↑ (>37), agglutinates on smearWarm sample at 37 °C for 15–30 min and rerun
Lipemia (or very high WBC)Hb falsely ↑ → MCH ↑, MCHC ↑; RBC and Hct correctPlasma blank / saline replacement
Hemolyzed sampleRBC count and Hct falsely low; RBC fragments counted as plateletsOnly Hb is valid → recollect
Clotted EDTA samplePlatelets and WBC falsely ↓ (consumed in clot)Reject
Nucleated RBCsCounted as WBCsCorrected WBC = WBC × 100 ÷ (100 + nRBC)
🧠 RULE OF THREE — Hb × 3 ≈ Hct (±3) and RBC × 3 ≈ Hb. When MCHC is above ≈37 g/dL, suspect an ERROR (lipemia, cold agglutinin, icterus, hemolysis) — only spherocytes give a true high MCHC.
  • EDTA is the anticoagulant of choice for CBC and smears (ICSH: K₂EDTA). Heparin causes platelet clumping and a blue smear background — use it only for osmotic fragility and RBC enzyme studies.
  • Blood bank: EDTA (pink) plasma is preferred; EDTA prevents in-vitro complement binding, so a positive DAT with EDTA reflects in-vivo coating. Pre-transfusion samples must be no older than 3 days if the patient was transfused or pregnant in the last 3 months.

📚 Book check — added from the two review books

  • CBC instrument errors (book table): lyse-resistant RBCs (Hb S, Hb C) → falsely ↑ WBC and Hb · giant platelets / platelet clumps → falsely ↑ WBC (giant platelets also ↑ RBC) and falsely ↓ platelets · schistocytes, microcytes → falsely ↑ platelets, falsely ↓ RBC · fragile WBCs → falsely ↓ WBC. (6.0 p.240)
  • Hemoglobin (cyanmethemoglobin) errors: falsely ↑ with lipemia, icterus, very high WBC, abnormal globulins (paraproteins) and lysis-resistant Hb S/C; falsely ↓ with sulfhemoglobin (the only Hb form the method does not measure). (6.0 pp.55, 240)
  • Glucose > 400 mg/dL → RBCs swell in the diluent → falsely ↑ MCV and Hct, ↓ MCHC. WBC > 50,000/µL → turbidity → falsely ↑ Hb (and MCV, Hct). (Hubbard Ch.3, p.87)
  • Carryover: a LOW WBC count run right after a very HIGH count can be falsely high (2–3%; up to 5% when successive counts differ by > 3:1) → repeat the low count. (Hubbard Ch.3, p.87)
  • ESR errors: tilted tube or high room temperature → falsely ↑ ESR; low temperature or an underfilled EDTA tube (excess EDTA shrinks RBCs, so they settle slowly) → falsely ↓ ESR. (6.0 pp.60, 70)
  • Coagulation tubes: use plastic or siliconized glass — glass activates factor XII and platelets stick to it. Hemolyzed samples must NOT be used for platelet aggregation (RBCs contain ADP). (6.0 p.74)

Sources: Medical Laboratory Science Review (Harr), Ch.1 p.4 Q9, p.36 Q11, p.37 Q12; Ch.2 p.44 Q3–Q5, p.46 Q19, p.68 Q8; SUCCESS! in Clinical Laboratory Science, Ch.2, Q252–Q253, Q259–Q261 (pp.313–315), Ch.3, Q58–Q60 (pp.401–403); BOC Study Guide, 6th ed., Ch.4, Q278–Q296 (pp.264–267), Q425 (p.286); Tietz, 7th ed., Ch.5 MCQ 7–8 (p.128.e16); DoH Past Paper Exam — Hematology/Blood Bank, p.2 Q9, Q17, Q20, p.11 Q64.

💡 UNDERSTAND THIS

10 · Recognizing specimen errors, and analytical and post-analytical errors

📚 Why this section: Calendar (Sample collection & errors) items: Analytical errors; Postanalytical errors; Common examination troubleshooting · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.11 §IV A CLIA 88 — procedure manual: rejection criteria, sources of error, panic values (pp.375–376) · Check book: Clinical Laboratory Science Review, 5th ed., Laboratory Operations — Delta check, sources of error (p.228); Chemistry — Q17 and rationale (pp.133, 136)

Recognize the pattern → name the cause

Result patternMost likely causeAction
Glucose very high (e.g., 1100 mg/dL), Na⁺ and Cl⁻ high/normal, K⁺ and HCO₃⁻ very low, other analytes dilutedDrawn ABOVE an IV of dextrose-saline (IV contamination)Recollect from the other arm
K⁺ very high + Ca²⁺ very low (+ ALP, Mg low) in a stable patientK-EDTA contamination (wrong order of draw or tube transfer)Recollect
Lithium extremely high (e.g., 14 mmol/L) in a well patientCollected in lithium heparinRecollect in plain/red tube
K⁺, LD, AST, phosphate high; pink serumIn vitro hemolysisRecollect
Low Na⁺ with very high TG or protein (indirect ISE); normal osmolalityPseudohyponatremiaDirect ISE
Delta-check failure on many unrelated analytesWrong patient (misidentification)Investigate, recollect
Delta flag on glucose, TG, phosphate, ALP onlyPatient not fastingComment / recollect fasting
Albumin higher than total protein, or a result physiologically impossibleRandom analytical errorRepeat the test
Anion gap <4 mmol/L, Na⁺ inappropriately lowLab error (or rare cation excess)Check Ca, albumin; repeat Na⁺

Delta check

A delta check compares a patient's present result with the previous result (usually within 24–72 h). A big difference that is not explained by the clinical situation suggests specimen misidentification, contamination or analytical error. It is the best tool to detect a mislabeled sample.

Analytical errors (review)

  • QC out of control → do not report → follow the out-of-control procedure → correct → rerun controls and patients.
  • Result above linearity → dilute and repeat (multiply by the dilution factor). Very high antigen in a sandwich immunoassay → hook effect (falsely LOW) → serial dilution.
  • Interference from drugs, heterophile antibodies, HIL.

Post-analytical errors

  • Transcription error, wrong units, wrong reference interval, report sent to wrong location.
  • Critical (panic) values must be telephoned immediately to a responsible caregiver; the receiver reads back the result; document name, time, read-back. Examples: K⁺ <2.5 or >6.5 mmol/L, glucose <40–50 mg/dL.
  • Long turnaround time (TAT) is a quality indicator; LEAN "value-stream mapping" studies each step from collection to result.

Specimen rejection criteria (summary)

REJECT when: • unlabeled / mislabeled / mismatch with request • wrong tube or anticoagulant for the test • clotted anticoagulated sample (CBC, coagulation) • underfilled citrate tube (QNS) or wrong blood:additive ratio • hemolyzed (for affected tests: K⁺, LD, AST, coagulation...) • delayed beyond stability / wrong temperature / not protected from light • leaking or contaminated container • insufficient volume ALWAYS: document, notify the ward, request a new specimen

📚 Book check — added from the two review books

  • Anion gap as a QC check: several patients in a row with a high Na⁺ and a high anion gap (e.g., 20–22) → suspect the sodium measurement, not the patients — even when controls are in range. (6.0 pp.133, 136)
  • Error type: specimen problems (wrong anticoagulant, drug interference, lipemia, hemolysis) and human errors are RANDOM errors — they affect single samples, not every result in the run. (6.0 p.228)

Sources: Medical Laboratory Science Review (Harr), Ch.5 p.236 Q52, p.313 Q13 & Q15–Q16, p.316 Q29 & Q31, p.323 Q46; Ch.9 p.535 Q65; SUCCESS! in Clinical Laboratory Science, Ch.13, Q38, Q44 (pp.1013–1014); Tietz, 7th ed., Ch.3 & Ch.4 (pp.76–78); DoH Past Paper Exam — Chemistry, p.1 Q10.

⚠️ VERIFIED

11 · Top exam traps

📚 Why this section: Calendar (Sample collection & errors) items: Common examination troubleshooting (review of traps) · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.1 §I F Pre-analytical variables (p.7) · Check book: Clinical Laboratory Science Review, 5th ed., Chemistry — Lipid specimen collection: turbid serum (p.105)

⚠️ EXAM TRAP Two classic specimen questions:
• Turbid (milky) serum = triglycerides (triglyceride-rich lipoproteins: chylomicrons and VLDL, the largest particles, scatter light). Cholesterol is carried mainly in small LDL/HDL particles that do not make serum turbid, and albumin is soluble. Turbidity usually appears when triglycerides are above ≈400 mg/dL.
• 24-hour urine: the collection STARTS by emptying the bladder and DISCARDING that urine (note the time); then collect all urine for 24 h, including the final void at the same time next day. Keeping the first urine gives more than 24 h of urine (over-collection). Measuring the total volume is the first step when the laboratory RECEIVES the container.

Top traps for this topic

  • Most errors are PRE-analytical. QC checks only the analytical phase.
  • Two identifiers; never room/bed number. Label at the bedside after collection. Unlabeled = reject.
  • Tourniquet ≤1 min. Long tourniquet / fist pumping → ↑ K⁺, ↑ lactate, ↑ proteins and protein-bound substances.
  • Order of draw: culture → blue → red/gold → green → lavender → gray. Skin puncture: EDTA first, serum last.
  • EDTA contamination = high K⁺ + low Ca²⁺ (+ low ALP, Mg). EDTA: no calcium. Gray (fluoride): no BUN by urease. Lithium heparin: no lithium level.
  • Citrate 3.2%, 9:1. Underfilled or Hct >55% → PT/aPTT falsely long. Reduce citrate: C = 0.00185 × V × (100 − Hct).
  • Above an IV: very high glucose, low K⁺ and HCO₃⁻, diluted everything else.
  • Hemolysis ↑ K⁺, LD, AST, ACP, phosphate, Mg; ↓ bilirubin (diazo). Na⁺ and calcium least affected.
  • Lipemia: pseudohyponatremia (indirect ISE), falsely high Hb/MCHC. Measure TG before ultracentrifugation.
  • Unseparated blood: glucose ↓ ~5–7%/h; K⁺ and phosphate ↑ (especially in the fridge); separate within 2 h.
  • ABG: heparin, no air bubbles, analyze within 30 min. Air → PO₂ ↑, PCO₂ ↓, pH ↑. Delay → PO₂ ↓, PCO₂ ↑, pH ↓.
  • Bilirubin: protect from light. Ammonia/lactate: on ice, test fast. Cold agglutinins: keep at 37 °C.
  • PT: 24 h at room temperature (fridge → FVII activation → short PT). aPTT: 4 h (factors V/VIII decay).

Sources: Tietz Textbook of Laboratory Medicine, 7th ed., Ch.4 (p.72, timed urine) and Ch.5 (pp.91–92, lipemia); Medical Laboratory Science Review (Harr), Ch.5, p.316 Q29. Other traps: see Sections 1–10.