Urinalysis I — Physical & Chemical Examination

Urine formation, composition & volume · Specimen types, 24-hour and drug-test collection · Handling, preservation & changes on standing · Color, clarity & odor · Specific gravity, refractometer & osmolality · Reagent strip technique, storage & QC · pH & protein (SSA, Bence Jones, microalbumin) · Glucose, Clinitest & ketones · Blood: hematuria, hemoglobinuria, myoglobinuria · Bilirubin & urobilinogen · Nitrite & leukocyte esterase · Interferences, ascorbic acid & result correlation

Simple English · DoH Past Paper Exam → BOC6e → Harr → SUCCESS! → Other References → Additional · Works offline · questions · Version 1.4

📘 Study progress

Press ✓ Mark section complete at the end of each section after you study it. Opening the page does not mark anything. Tap a chip to jump. Labels: 🔥 very high-yield · 📌 must memorize · ⚠️ exam trap · 🧠 memory trick · 🔬 lab connection · 💡 understand this.

START HERE

1 · How urine is made — and what normal urine contains

📚 Why this section: Calendar (Urinalysis I) items: Renal physiology relevant to urinalysis; Urine formation · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §I The renal system — structure, urine formation, constituents (pp.313–314) and §III D Urine volume (p.322) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Renal physiology; Urine volume; Urine composition; Hormones (pp.81–82)

Urine is the end result of three kidney jobs: filter the plasma, take back what the body needs, and add what the body wants to remove. Every urinalysis (UA) result is a clue about one of these jobs.

Blood → GLOMERULUS (filters plasma; cells and big proteins stay in blood) filtrate: specific gravity (SG) ≈ 1.010, osmolality ≈ 280–300 mOsm/kg ↓ PROXIMAL TUBULE (takes back ~65%: glucose, amino acids, salt, water, HCO₃⁻) ↓ LOOP OF HENLE (descending: water out · ascending: salt out, NOT water) ↓ DISTAL TUBULE + COLLECTING DUCT aldosterone → Na⁺ back in, K⁺ out Antidiuretic Hormone (ADH, vasopressin) → WATER back in ↓ FINAL URINE (SG 1.003–1.035 depending on hydration)
🔥 VERY HIGH-YIELD — Glomerular filtrate SG = 1.010. If the tubules cannot concentrate or dilute, the urine stays fixed at 1.010 = isosthenuria (severe renal disease). Below 1.010 = hyposthenuria; above 1.010 = hypersthenuria.
🧠 MEMORY TRICK — Who controls what?
• Countercurrent mechanism (loop of Henle, medulla): descending limb lets water out; ascending limb pumps salt out but is impermeable to water → the medulla stays salty.
• Antidiuretic Hormone (ADH) = water: released when plasma osmolality is HIGH; opens water channels in the collecting duct → small volume of concentrated urine.
• Renin → aldosterone = salt: renin is released when afferent arteriole pressure is LOW; aldosterone saves Na⁺ and secretes K⁺ ("save salt, pay with potassium").
• Sodium is a threshold substance; potassium is not (it is secreted even when serum K⁺ is low).
⚠️ EXAM TRAP — Low PRESSURE → renin. High OSMOLALITY → ADH. Examiners swap them. Also: the proximal tubule reabsorbs the MOST water (~65%), but the loop of Henle creates the concentration gradient.

Renal threshold

Renal threshold = the blood level a substance must pass before it "spills" into urine. The tubule carrier is full (tubular maximum) → the rest is excreted.

🔬 LAB CONNECTION — Renal threshold for glucose ≈ 160–180 mg/dL (8.8–9.9 mmol/L). Blood glucose above this → glycosuria. Pregnancy LOWERS the threshold, so glycosuria can appear with a normal blood glucose.

Normal composition

PartMain itemRemember
Water~95%The solvent
Major ORGANIC soluteUreaFrom protein / amino acid breakdown (60–90% of nitrogenous waste)
Major INORGANIC soluteSodium chloride (NaCl)Varies with salt intake
OthersCreatinine, uric acid, K⁺, phosphate, sulfate, ammoniumEverything found in urine must be water soluble

💡 UNDERSTAND THIS — If a body fluid contains high urea and creatinine, it is probably urine (useful when a surgeon asks "is this abdominal fluid urine?").

Urine volume

TermMeaningTypical cause
Normal≈ 600–1,600 mL/day (average 1,200–1,500)Depends on fluid intake
Polyuria> 2,000 mL/dayDiabetes mellitus (DM), diabetes insipidus (DI), diuretics, high fluid intake
Oliguria< 400–500 mL/dayDehydration, shock, acute kidney injury
AnuriaNo urine (cessation of flow)Severe kidney failure, obstruction
Nocturia> 500 mL at nightChronic renal disease, pregnancy
POLYURIA — which diabetes? Diabetes MELLITUS : no insulin → glucose spills → water follows glucose → HIGH volume + HIGH SG (glucose adds weight) + glucose positive Diabetes INSIPIDUS : no ADH (or kidney ignores ADH) → water not taken back → HIGH volume + LOW SG (≈1.001–1.005) + glucose negative
🧠 MEMORY TRICK — "MELLITUS = sweet and HEAVY; INSIPIDUS = tasteless and LIGHT." Pale urine with a HIGH SG = think diabetes mellitus.

📚 Book check — added from the two review books

  • The glomerulus is a non-selective filter: it lets through everything smaller than about 70,000 MW (water, ions, glucose, amino acids, urea, creatinine, uric acid, ammonia) and keeps cells and large proteins in the blood. The kidneys receive ≈1,200 mL of blood per minute; ≈120 mL/min (one-fifth of the plasma) becomes filtrate, with pH 7.4. (Hubbard Ch.9, pp.313–314; 6.0 p.81)
  • Reabsorption: ACTIVE = glucose, amino acids and salts (proximal tubule), chloride (ascending loop of Henle), sodium (distal tubule). PASSIVE = water (all parts except the ascending loop), urea (proximal tubule and ascending loop), sodium (ascending loop). (Hubbard Ch.9, p.314)
  • Tubules also SECRETE: proximal tubule → H⁺, sulfates, glucuronides and drugs; distal and collecting tubules → K⁺, H⁺ and ammonia (K⁺ is exchanged for Na⁺). (6.0 p.81)
  • Urea makes up about half of all dissolved solids in urine. Chloride is the major inorganic solute, followed by sodium and then potassium. (Hubbard Ch.9, p.314; 6.0 p.82)
  • More causes of volume change: polyuria also with caffeine and alcohol; oliguria with vomiting, diarrhea, heavy sweating and severe burns; anuria also with ↓ blood flow to the kidney (↓ cardiac output). (Hubbard Ch.9, p.322; 6.0 p.82)

📚 How the sections were chosen

Two sources: the fixed calendar list for this day and the chapter headings of A Concise Review of Clinical Laboratory Science (Hubbard). Check book: Clinical Laboratory Science Review, 5th ed. (6.0).

#Study sectionCalendar items it coversBook heading (Hubbard, page)
1Urine formation, composition & volumeRenal physiology; Urine formationCh.9 §I The renal system; §III D Urine volume (pp.313–314, 322)
2Specimen types & collectionUrine specimen collectionCh.9 §II C–D Types / methods of collection (pp.317–318)
3Handling, preservation & changes on standingPreservationCh.9 §II E Specimen preservation; Table 9–2 (pp.318, 323)
4Color, clarity & odorPhysical examination; Color; AppearanceCh.9 §III A–B Appearance, Odor (pp.319–321)
5Specific gravity, refractometer & osmolalitySpecific gravity; RefractometerCh.9 §III C Specific gravity (pp.321–322)
6Reagent strips: technique, care & QCChemical strip testingCh.9 §II B Quality control; §IV B Reagent strips (pp.315–317, 322–324)
7pH & protein (SSA, microalbumin)pH; ProteinCh.9 §IV B 3a, 3d; §IV C 2 (pp.323, 325, 327)
8Glucose, Clinitest & ketonesGlucose; KetonesCh.9 §IV B 3e–f; §IV C 1 (pp.325–327)
9Blood: hematuria, hemoglobinuria, myoglobinuriaBloodCh.9 §IV B 3c Blood (p.325)
10Bilirubin & urobilinogenBilirubin; UrobilinogenCh.9 §IV B 3g–h; §IV C 3 Ictotest (pp.326–327)
11Nitrite & leukocyte esteraseNitrite; Leukocyte esteraseCh.9 §IV B 3i–j (p.326)
12Interferences, discrepancies & top trapsFalse-positive/false-negative reactions; Important interferencesCh.9 §II B 8e; Table 9–3 (pp.317, 324)
13Urinalysis automationChemical strip testing (automated readers); Specific gravity (harmonic oscillation)Ch.9 §VI Automation in the urinalysis laboratory (p.335)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.2 & Ch.3, pp.29–33, Table 3–1; Ch.4, p.48; Medical Laboratory Science Review (Harr), Ch.6, pp.329, 332–334, Q1–Q3, Q17, Q19, Q25–Q26; Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, p.352.e3; DoH Past Paper Exam — Chemistry, p.12, Q6.

📌 MUST MEMORIZE

2 · Urine specimen types and correct collection

📚 Why this section: Calendar (Urinalysis I) items: Urine specimen collection · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §II C–D Types of urine specimens; Methods of collection (pp.317–318) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Specimen collection and handling; 24-hour urine (p.83)

The right specimen depends on the question the doctor is asking. Most exam questions ask "which specimen is BEST for…".

SpecimenBest forKey point
RandomRoutine screeningMost common, easiest; may be dilute
First morning (8-hour)Routine screening (ideal), pregnancy test, orthostatic protein, nitriteMost concentrated → abnormalities easier to detect; bacteria had time to make nitrite
Fasting (second morning)Diabetic screening / glucose2nd void after fasting (1st morning may hold last night's meal glucose)
2-hour postprandialDiabetic monitoringVoid before meal, collect 2 h after
2-hour afternoon (2–4 pm)UrobilinogenUrobilinogen excretion is highest in the afternoon
24-hour (timed)Quantitative tests (protein, creatinine clearance, hormones, catecholamines)Analytes with diurnal variation
Midstream clean-catchRoutine UA and bacterial cultureClean area, discard first part, collect middle
CatheterizedCulture when patient cannot void cleanlyLong-term (indwelling) catheter = Foley catheter
Suprapubic aspirationBladder urine for anaerobic culture, infantsNeedle through abdominal wall → no contamination
Three-glass collectionProstatic infection3rd specimen (after prostate massage) WBC/bacteria ≥10× the 1st
Pediatric bagInfantsAdhesive plastic bag; sterile if for culture

The 24-hour collection — step by step

Day 1, 8 a.m. : patient EMPTIES bladder → DISCARDS this urine → note the time Next 24 h : collect ALL urine in the container (keep refrigerated / preservative if required) Day 2, 8 a.m. : patient voids → ADDS this urine to the container → collection ends Laboratory : FIRST step on receipt = measure and record the TOTAL VOLUME (then mix, aliquot) Completeness : check total creatinine → adult ≈ 1–2 g/day (if <1 g/day, suspect under-collection)
⚠️ EXAM TRAP — "First step" has two meanings. For the PATIENT: void and discard the first urine. For the LABORATORY receiving the container: measure the total volume. Read who is acting in the question.

Containers and labeling

  • Clean, dry, leak-proof, clear, wide mouth, flat bottom; ≈50 mL capacity (12 mL needed for microscopy). Sterile container for culture.
  • Label goes on the container, NOT the lid (lids are removed). Name, ID number, date and time of collection.
  • Reject: unlabeled, label ≠ requisition, contaminated with feces/toilet paper, leaking/contaminated outside, insufficient volume, improperly transported (e.g., culture urine kept at room temperature too long).

Drug-of-abuse specimens (chain of custody)

  • Chain of custody form documents every person who handles the specimen.
  • Bluing dye in the toilet water, taped faucets; volume 30–45 mL.
  • Temperature checked within 4 minutes: 32.5–37.7 °C. Out of range → new specimen.
  • Specimen validity tests: temperature, pH, SG, creatinine, oxidants/nitrite (adulterants). Dilute: creatinine <20 mg/dL + SG <1.003. Substituted: creatinine <5 mg/dL + SG <1.002.

📚 Book check — added from the two review books

  • Pediatric bag: check the bag about every 15 minutes. It has many sources of contamination. (6.0 p.83)
  • A catheter passed up into the ureter collects urine from each kidney separately. This checks how well a single kidney works. (Hubbard Ch.9, p.318)
  • Three-glass test: if the 2nd (midstream) sample already contains bacteria (kidney or bladder infection), the result of the 3rd (after prostatic massage) sample is invalid. (Hubbard Ch.9, p.318)
  • The first morning specimen is also used for hormones and other low-level substances that are hard to find in a random urine. Timed collections are usually 2, 12 or 24 hours, and exact timing is essential. (Hubbard Ch.9, p.318)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.3, pp.32–37, Table 3–4; Medical Laboratory Science Review (Harr), Ch.6, p.332 Q16, p.378 Q30, p.379 Q31; BOC Study Guide, 6th ed., Ch.2, p.86, Q9; DoH Past Paper Exam — Chemistry, p.5 Q76–Q78, p.11 Q86, p.12 Q97, p.23 Q1.

🔥 VERY HIGH-YIELD

3 · Specimen handling, preservation and what changes when urine stands

📚 Why this section: Calendar (Urinalysis I) items: Preservation · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §II A 4 and §II E Specimen preservation (pp.315, 318); §IV A Table 9–2 changes in unpreserved urine (pp.322–323) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Analysis; Effects of prolonged sitting; Refrigeration (p.83)

Rule: deliver promptly and test within 2 hours. If that is not possible → refrigerate (2–8 °C) or add a suitable chemical preservative.

🔥 VERY HIGH-YIELD — Refrigeration at 2–8 °C is the most routinely used preservation. Culture urine can be held refrigerated up to 24 h. Refrigerated urine must return to room temperature before reagent strip testing (strip enzymes are temperature dependent).

Changes in unpreserved urine left at room temperature > 2 h

↑ INCREASESWhy↓ DECREASESWhy
pHBacteria split urea → ammonia; CO₂ lossGlucoseGlycolysis by cells and bacteria
NitriteNitrate-reducing bacteria multiplyKetonesAcetone evaporates; bacteria use acetoacetate
BacteriaMultiplicationBilirubinLight → oxidized to biliverdin
TurbidityBacterial growth, amorphous crystalsUrobilinogenOxidized to urobilin
Odor (ammonia)Urea breakdownRBCs, WBCs, castsLyse in dilute, alkaline urine
Color change / darkeningOxidation/reduction of metabolitesClarityBecomes cloudy
🧠 MEMORY TRICK — Standing urine: "pH, Nitrite, Bacteria GO UP; G-K-B-U (Glucose, Ketones, Bilirubin, Urobilinogen) and cells GO DOWN." Protein is the most stable.

Preservatives (no ideal preservative exists)

PreservativeGood forProblem
RefrigerationNo chemical interference; stops bacterial growth (24 h)↑ SG by urinometer; precipitates amorphous phosphates/urates
Boric acidProtein and formed elements; culture transport (bacteriostatic, keeps pH ~6)Interferes with pH, drug and hormone tests; crystals if too much
FormalinExcellent sediment (cells, casts)Reducing agent → false results for glucose, blood, LE, copper reduction
ThymolGlucose and sedimentInterferes with acid precipitation protein test
Sodium fluoridePrevents glycolysis; drug analysisInhibits strip glucose, blood, leukocyte tests
TolueneNo interference with routine testsFloats on top, clings to pipettes
Hydrochloric acid / acidSome 24-h tests (e.g., catecholamines per lab procedure)Not for routine UA
⚠️ EXAM TRAP — A culture specimen that sat unrefrigerated for >2 h must be rejected (bacteria have multiplied). The same specimen is acceptable if it was refrigerated immediately (up to 24 h) or put in a boric acid transport tube.

📚 Book check — added from the two review books

  • The time limit starts at voiding, NOT when the specimen arrives in the lab. Hubbard: analyze within 1 hour, or store in a dark refrigerator (4–7 °C); all testing must be done within 2 hours. (6.0 p.83; Hubbard Ch.9, pp.315, 318)
  • After refrigeration, let the urine return to room temperature (about 15 minutes) before testing. (6.0 p.83)
  • Most enteric bacteria double every 20 minutes in unpreserved urine. Their peroxidase can make the blood pad falsely positive. (Hubbard Ch.9, p.323)
  • On standing, Trichomonas stop moving or die. Without movement they can be mistaken for WBCs. (Hubbard Ch.9, p.323)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.3, pp.33–35, Tables 3–2 and 3–3; Medical Laboratory Science Review (Harr), Ch.6, p.330 Q4–Q5, p.332 Q14; BOC Study Guide, 6th ed., Ch.2, pp.85–86, Q2–Q8; SUCCESS! in Clinical Laboratory Science, Ch.11, Q5 (p.936), Q39 (p.940); DoH Past Paper Exam — Chemistry, p.1 Q3, p.25 Q14.

PHYSICAL EXAMINATION

4 · Color, clarity (appearance) and odor

📚 Why this section: Calendar (Urinalysis I) items: Physical examination; Color; Appearance · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §III A Appearance, Table 9–1, and §III B Odor (pp.319–321) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Physical examination: odor, clarity, color; Color as a clue (pp.83–84)

Normal yellow color comes from urochrome (excreted at a constant rate). Pale = dilute; dark yellow/amber = concentrated (or a pigment). So color gives a quick idea of concentration.

ColorCommon causesClue
Colorless / pale yellowDilute: high fluid intake, DI; DM (pale but HIGH SG)Check SG
Dark yellow / amberConcentrated (dehydration); bilirubin; carrots (carotene)Bilirubin → YELLOW foam when shaken
Orange / orange-redPhenazopyridine (Pyridium) — urinary tract analgesic; rifampinThick orange pigment masks strip colors
Red, cloudyIntact RBCs (hematuria)RBCs seen on microscopy
Red, clearHemoglobin (red plasma), myoglobin (clear plasma), porphyrins (port-wine), beets (genetic), drugsStrip blood + with Hb/Mb; NEGATIVE with porphyrins and beets
Brown / blackHomogentisic acid (alkaptonuria) and melanin (malignant melanoma) darken on standing; methemoglobin (acid urine with Hb)Turns black on standing or with air
Port-winePorphyrins (porphyria cutanea tarda, erythropoietic porphyria)Red fluorescence under UV light
Green / blue-greenBiliverdin (oxidized bilirubin), Pseudomonas infection, methylene blue, amitriptyline—
🧠 MEMORY TRICK — "Cloudy red = Cells; Clear red = Chemical (Hb, Mb, porphyrin, beet)." Yellow foam = bilirubin; white foam = protein.

Clarity (transparency)

Report clarity after mixing the specimen well (formed elements settle). Fresh normal urine is clear.

TurbiditypHLookDissolves with
Amorphous uratesACIDPink "brick dust" after refrigeration (uroerythrin)Warming to 60 °C or alkali
Amorphous phosphates / carbonatesALKALINEWhite precipitateDilute acetic acid (carbonates fizz)
WBCs, bacteria, yeastAnyCloudy, often with odor— (pathologic)
Lipids, lymph (chyle)AnyMilky— (nephrotic syndrome, chyluria)
Squamous cells, mucusAnyHazy— (contamination)

💡 UNDERSTAND THIS — A cloudy urine after a meal (alkaline tide) with a normal strip is usually amorphous phosphates — not disease.

Odor

OdorCause
Faint aromaticNormal fresh urine
Foul, ammoniaOld specimen or UTI with urease bacteria (e.g., Proteus)
Fruity, sweetKetones (DM, starvation, vomiting)
Maple syrupMaple syrup urine disease
MousyPhenylketonuria (PKU) — phenylpyruvic acid
RancidTyrosinemia
Sweaty feetIsovaleric acidemia
BleachContamination / adulteration

📚 Book check — added from the two review books

  • Three normal pigments: urochrome (yellow; the main one), uroerythrin (red) and urobilin (orange-red; formed when urobilinogen is oxidized). (Hubbard Ch.9, p.320)
  • Red or red-brown is the most common abnormal urine color. It usually means blood or hemoglobin. In a female patient, think of menstrual contamination. (Hubbard Ch.9, p.320)
  • Blue urine = indican (from abnormal breakdown of tryptophan; intestinal infection). Orange urine can also come from nitrofurantoin and acriflavine. (Hubbard Ch.9, pp.319–320; 6.0 p.84)
  • Brown-black urine can also come from levodopa and metronidazole (Flagyl). In alkaptonuria (no homogentisic acid oxidase), fresh urine looks normal and turns black on standing or when alkalinized. In melanoma, melanogen changes to black melanin on exposure to light. (Hubbard Ch.9, pp.319–320)
  • Check clarity at room temperature. Non-pathologic turbidity: amorphous crystals, mucus, powders, squamous cells, sperm in a female sample. Pathologic turbidity: bacteria, yeast, cells, abnormal crystals, lipids, prostatic fluid. Sperm in a male sample can be normal (recent ejaculation), but genitourinary disease must also be considered. (Hubbard Ch.9, pp.320, 335)
  • More odors: no odor at all may suggest acute tubular necrosis; cabbage = methionine malabsorption; rotting fish = trimethylaminuria; sweaty feet = isovaleric (and glutaric) acid. (Hubbard Ch.9, p.321)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.4, pp.41–45 and p.49, Table 4–6; Medical Laboratory Science Review (Harr), Ch.6, pp.330–331, Q6–Q13; BOC Study Guide, 6th ed., Ch.2, pp.87–88, Q14–Q26; SUCCESS! in Clinical Laboratory Science, Ch.11, Q2–Q3, Q8 (pp.935–936); Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, p.352.e1; DoH Past Paper Exam — Chemistry, p.12, Q12.

🔥 VERY HIGH-YIELD

5 · Specific gravity (SG), the refractometer and osmolality

📚 Why this section: Calendar (Urinalysis I) items: Specific gravity; Refractometer · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §III C Specific gravity, refractive index and osmolality (pp.321–322); §II B 4e refractometer QC (pp.316–317) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Specific gravity; Specific gravity measurement (pp.84–85)

SG = density of urine compared with the same volume of distilled water at the same temperature. It shows how well the tubules concentrate urine. SG is affected by the number AND the size/weight of particles (big molecules like glucose, protein and X-ray dye raise it a lot).

Osmolality depends ONLY on the number of dissolved particles. It is the more accurate measure of concentrating ability. Protein (a colloid) raises SG but hardly changes osmolality.

MethodPrincipleKey facts
Urinometer (hydrometer)Density (float)Needs 10–15 mL; temperature correction ±0.001 per 3 °C from calibration temperature (cold → subtract); least accurate, not recommended
RefractometerRefractive index = velocity of light in AIR ÷ velocity in SOLUTION1–2 drops; temperature-compensated (15–38 °C) → no temperature correction; still correct for glucose and protein
Harmonic oscillation densitometryDensity (sound-wave frequency change)Automated; linear to 1.080
Reagent strippKa change of a polyelectrolyte (ionic strength) + bromthymol blueMeasures only IONS: not affected by glucose, protein or X-ray contrast dye; add +0.005 when pH ≥ 6.5; blue = low SG, yellow-green = high SG
OsmometerFreezing point depressionNumber of particles; best measure

Refractometer calibration and corrections

Zero check : distilled water must read 1.000 (if not → adjust the zero-set screw) High checks : 5% NaCl = 1.022 ± 0.001 9% sucrose = 1.034 ± 0.001 Corrections : subtract 0.003 for each 1 g/dL PROTEIN subtract 0.004 for each 1 g/dL GLUCOSE Example : reading 1.030 with 1 g/dL protein + 1 g/dL glucose 1.030 − 0.003 − 0.004 = 1.023 Dilution : above the scale → dilute; multiply ONLY the decimal part 1:2 dilution reads 1.025 → true SG = 1.050
🔥 VERY HIGH-YIELD — Glucose and protein make the refractometer reading too HIGH, so you SUBTRACT their contribution. SG 1.040 with 1 g/dL glucose → corrected SG = 1.036.

Interpreting SG

SGMeaning
1.003–1.035Normal random range (most 1.015–1.025); ≥1.023 on a random specimen = good concentrating ability
< 1.003Probably not urine (or adulterated/substituted)
Fixed 1.010Isosthenuria — tubules lost concentrating and diluting ability (severe renal disease)
< 1.010 (e.g., 1.001–1.005)Hyposthenuria — dilute; diabetes insipidus, high water intake
> 1.035 (up to 1.040–1.050)Radiographic (X-ray) contrast dye after intravenous pyelogram (IVP), dextran/plasma expanders, very high glucose → measure SG by reagent strip or osmometry
⚠️ EXAM TRAP — X-ray contrast dye makes refractometer SG extremely high and gives a false-positive SSA protein, but does NOT affect the strip SG pad. Best method after contrast = reagent strip (or osmolality).

📚 Book check — added from the two review books

  • Another refractometer check solution: 3% NaCl = 1.015 ± 0.001. Calibrate the refractometer on each day of use with water, NaCl or sucrose solutions and controls, and record the results. (Hubbard Ch.9, pp.316–317, 321)
  • The refractometer scale reads only up to 1.035. Very concentrated urine or urine with X-ray dye must be diluted and read again. (Hubbard Ch.9, p.321)
  • The kidney can concentrate urine to about 1.040 at most. A higher SG means a large amount of glucose or radiographic dye (dye often gives SG > 1.040). (6.0 p.84; Hubbard Ch.9, p.334)
  • Strip SG is NOT raised by glucose, urea or X-ray dye (they do not ionize). But high protein can raise it (protein carries anions), and highly buffered alkaline urine lowers it. The strip reads in 0.005 steps from 1.000 to 1.030. (Hubbard Ch.9, pp.322, 324; 6.0 p.88)
  • SG normally goes down when urine volume goes up (inverse relationship). It goes up as the color gets darker (direct relationship). Exception: pale urine with a high SG = glucose (diabetes mellitus). (Hubbard Ch.9, p.321; 6.0 p.84)
  • Osmolality is measured by a freezing-point depression OR vapor-pressure osmometer. In renal disease it is better than SG, because protein and sugar raise SG. (Hubbard Ch.9, p.322)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.4, pp.46–49; Ch.5, pp.74–75; Medical Laboratory Science Review (Harr), Ch.6, pp.332–335, Q18–Q22, Q26, Q30; BOC Study Guide, 6th ed., Ch.2, pp.88–90, Q27–Q40; Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, p.352.e4; DoH Past Paper Exam — Chemistry, p.3 Q42, p.7 Q19, p.12 Q11.

📌 MUST MEMORIZE

6 · Reagent strips ("dipsticks") — technique, storage, quality control and principles

📚 Why this section: Calendar (Urinalysis I) items: Chemical strip testing · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §II B Quality control in urinalysis (pp.315–317) and §IV B Reagent strip screening tests, Table 9–3 (pp.322–324) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Reagent strip reactions (p.88); Strip correlations (p.87)

Correct technique

  • Mix the specimen well (RBCs and WBCs settle → unmixed = false-low blood and LE).
  • Specimen at room temperature (cold urine slows the enzymatic reactions: glucose, blood, LE).
  • Dip briefly and completely. Leaving the strip in urine too long leaches reagents (e.g., removes the protein-pad buffer).
  • Remove excess urine (touch the edge, blot). Excess urine causes runover: the acid buffer of the protein pad can run onto the pH pad → falsely ACID pH.
  • Read at the stated time (pH immediately … leukocyte esterase last at 120 seconds) in good light.

Storage

  • Opaque, tightly closed bottle with desiccant; cool dry place, room temperature below 30 °C; do NOT refrigerate or freeze.
  • Avoid volatile fumes; do not touch the pads; never use after expiry or if pads are discolored.

Quality control

  • Positive AND negative controls at least every 24 hours (many labs: every shift), with each new bottle/lot, and when results are questionable.
  • Distilled water is not a suitable negative control (strips need urine-like ionic strength; water can give a false-positive blood).
  • Positive control must agree within ± one color block. Confirmatory (backup) tests also need controls.

Principle of each pad — the master table

PadPrinciple / reagentConfirm / backup test
pHDouble indicator: methyl red + bromthymol blue (orange pH 5 → blue pH 9)pH meter
ProteinProtein error of indicators: tetrabromphenol blue buffered at pH 3SSA (3% sulfosalicylic acid)
GlucoseDouble sequential enzyme: glucose oxidase + peroxidase + chromogen(Clinitest is NOT a confirmation — it screens reducing sugars)
KetonesSodium nitroprusside (nitroferricyanide) + acetoacetic acid → purpleAcetest tablet
BloodPseudoperoxidase activity of heme + peroxide + tetramethylbenzidineMicroscopy; ammonium sulfate (Hb vs Mb)
BilirubinDiazo reaction: diazonium salt (2,4-dichloroaniline) → azodyeIctotest tablet
UrobilinogenEhrlich reaction: p-dimethylaminobenzaldehyde (Multistix) or diazo (Chemstrip)Watson-Schwartz
NitriteGreiss reaction: p-arsanilic acid/sulfanilamide + benzoquinoline → pinkCulture
LeukocytesLeukocyte esterase hydrolyses an ester (indoxylcarbonic acid ester) + diazonium salt → purpleMicroscopy
Specific gravitypKa change of a polyelectrolyte + bromthymol blueRefractometer / osmometer
🧠 MEMORY TRICK — The three DIAZO pads: "Bilirubin, Nitrite, Leukocytes" (and urobilinogen on Chemstrip). That is why ascorbic acid (which destroys diazonium salts and peroxide) lowers them. The two PEROXIDE pads: glucose and blood.

📚 Book check — added from the two review books

  • After dipping, draw the strip along the edge of the container and hold it horizontal. Dipping too long or holding the strip vertical lets reagents run from one pad into the next. Read beside the color chart in good light. (Hubbard Ch.9, p.316)
  • QC out of range? Step 1: test a new bottle of strips with the controls; if it is in range, discard the old bottle. Step 2: if still out, open a new control. Step 3: if still out, tell the supervisor before testing any patients. Record every problem and how it was fixed. (Hubbard Ch.9, p.317)
  • When you open a new reagent or control bottle, write the date and your initials on it. Record lot numbers and expiry dates. Never use a reagent past its expiry date, even if it seems to work. (Hubbard Ch.9, p.316)
  • Reagents and methods differ between manufacturers and even between lots. Always read the package insert to know each pad's principle and interferences. (Hubbard Ch.9, p.323)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.5, pp.54–57 and pp.59–75 (reagent strip summaries); Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, pp.352.e1–352.e4; BOC Study Guide, 6th ed., Ch.2, pp.90–91, Q44–Q52; SUCCESS! in Clinical Laboratory Science, Ch.11, Q9 (p.936).

🔥 VERY HIGH-YIELD

7 · Urine pH and protein

📚 Why this section: Calendar (Urinalysis I) items: pH; Protein · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §IV B 3a pH and 3d Protein (pp.323, 325); §IV C 2 Precipitation tests for protein (p.327) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — pH (p.84); Protein; Microalbuminuria (p.85)

pH

  • Fresh urine pH 4.5–8.0 (4.5 = the lowest the kidney can make). First morning usually 5.0–6.0; more alkaline after meals (alkaline tide).
  • pH 9.0 = improperly preserved specimen → recollect (fresh urine never reaches 9).
  • pH helps to: identify crystals, judge specimen acceptability, follow acid-base disorders and renal stones.
ACID urineALKALINE urine
High-protein / meat diet, cranberry juice · DM / ketosis, starvation · dehydration, diarrhea · emphysema (respiratory acidosis) · acid-producing bacteria (E. coli) · methenamineVegetarian diet · after meals · vomiting (metabolic alkalosis) · hyperventilation (respiratory alkalosis) · renal tubular acidosis (RTA) · urease bacteria (Proteus) · old specimen
⚠️ EXAM TRAP — In renal tubular acidosis the BLOOD is acidic but the URINE is alkaline (the tubule cannot secrete H⁺ / reabsorb HCO₃⁻). Normally acidosis → acid urine.

Protein

Normal: <10 mg/dL or <150 mg/day (mostly albumin, plus Tamm-Horsfall protein). Clinical proteinuria ≥30 mg/dL. Protein is the strip test most indicative of renal disease.

STRIP PRINCIPLE — "protein error of indicators" Tetrabromphenol blue + acid buffer (pH 3) → YELLOW Protein (albumin) ACCEPTS H⁺ from the indicator → color shifts GREEN → BLUE (pH stays 3 — the color changes because of PROTEIN, not pH) Most sensitive to ALBUMIN (many amino groups) → poor for globulins, Bence Jones, Hb
Reagent strip proteinSSA (3% sulfosalicylic acid, cold precipitation)
DetectsMainly albumin (≈15–30 mg/dL)ALL proteins (albumin, globulins, Bence Jones), more sensitive
FALSE POSITIVEHighly buffered ALKALINE urine (pH ≥8–9), leaving strip in urine too long, quaternary ammonium compounds/detergents, chlorhexidine, pigmented urine (phenazopyridine), trace with high SGRadiographic contrast dye, tolbutamide, penicillins, cephalosporins, sulfonamides, turbid uncentrifuged urine
FALSE NEGATIVEProteins other than albumin (Bence Jones, globulins), very dilute urine, microalbuminuriaHighly alkaline urine (pH neutralizes the acid)
🔥 VERY HIGH-YIELD — Strip NEGATIVE + SSA POSITIVE = a protein other than albumin (e.g., Bence Jones light chains in multiple myeloma) — or an SSA false-positive (contrast dye, tolbutamide, antibiotics). Strip POSITIVE + SSA negative (alkaline urine) = suspect strip false-positive.

Types of proteinuria

TypeExamples
Prerenal (overflow)Hemoglobin, myoglobin, acute-phase reactants, Bence Jones protein (multiple myeloma) — often missed by the strip
Renal — glomerularGlomerulonephritis, nephrotic syndrome, diabetic nephropathy, pre-eclampsia, exercise, dehydration, orthostatic
Renal — tubularFanconi syndrome, heavy metals, toxins; β₂-microglobulin (strip poorly sensitive)
PostrenalLower UTI/inflammation, menstrual blood, prostatic fluid, vaginal secretions
  • Orthostatic (postural) proteinuria: young adults; protein only after standing. Test: first morning specimen NEGATIVE, specimen after hours upright POSITIVE. (Both positive → NOT orthostatic.)
  • Bence Jones protein: coagulates at 40–60 °C and dissolves at 100 °C (screen); confirm by serum/urine electrophoresis and immunofixation.
  • Microalbuminuria (moderately increased albuminuria): 30–300 mg/24 h or albumin:creatinine ratio (ACR) 30–300 mg/g. Early sign of diabetic nephropathy (also hypertension, cardiovascular risk). Strips: immunochemical (Micral) or albumin dye-binding + creatinine pad (copper–creatinine pseudoperoxidase) → ACR on a random/first morning specimen (creatinine corrects for hydration).
🔬 LAB CONNECTION — ACR = urine albumin (mg/dL) ÷ urine creatinine (mg/dL) × 1000 → mg/g. Example: 16 mg/dL ÷ 140 mg/dL × 1000 = 114 mg/g → microalbuminuria range.

📚 Book check — added from the two review books

  • SSA procedure: mix equal volumes of urine and 3% sulfosalicylic acid (or trichloroacetic acid), let it stand 10 minutes, then grade the turbidity. Negative = no turbidity (≤5 mg/dL) · 1+ = faint turbidity, no granules (≈50 mg/dL) · 2+ = granules, no flocculation (≈200 mg/dL) · 3+ = granules + flocculation (≈500 mg/dL) · 4+ = clumps (≥1 g/dL). (Hubbard Ch.9, p.327)
  • SSA is sensitive to about 5–10 mg/dL. It detects albumin, globulins, glycoproteins and Bence Jones protein. If X-ray dye gives a false-positive SSA, the SG is usually > 1.035 and typical crystals are seen in the sediment. (Hubbard Ch.9, p.327)
  • Transient (temporary) proteinuria: fever, exercise, dehydration, acute illness, pregnancy, and orthostatic (after long standing). (Hubbard Ch.9, p.325; 6.0 p.85)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.5, pp.56–61, Tables 5–1 and 5–2; Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, pp.352.e2–352.e5; Medical Laboratory Science Review (Harr), Ch.6, pp.333–336 Q23–Q36, p.371 Q1, p.373 Q10, p.374 Q15; SUCCESS! in Clinical Laboratory Science, Ch.11, Q4, Q10, Q12, Q21 (pp.935–938); DoH Past Paper Exam — Chemistry, p.8 Q22, p.11 Q90, p.20 Q76.

🔥 VERY HIGH-YIELD

8 · Glucose, copper reduction (Clinitest) and ketones

📚 Why this section: Calendar (Urinalysis I) items: Glucose; Ketones · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §IV B 3e Glucose and 3f Ketones (pp.325–326); §IV C 1 Clinitest (pp.326–327) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Glucose; Clinitest; Ketones (pp.85–86)

Glucose

Hyperglycemia-associated glycosuria (blood glucose > 160–180 mg/dL): DM, gestational DM, Cushing, acromegaly, hyperthyroidism, pheochromocytoma, pancreatitis, stress / CNS damage (hormones that oppose insulin) Renal glycosuria (NORMAL blood glucose, tubules cannot reabsorb): Fanconi syndrome, advanced renal disease, pregnancy (lower threshold)
STRIP — double sequential enzyme reaction (SPECIFIC for glucose) 1) glucose + O₂ --glucose oxidase--> gluconic acid + H₂O₂ 2) H₂O₂ + chromogen (KI or TMB) --peroxidase--> colored oxidized chromogen
  • False positive: container contaminated with peroxide or strong oxidizing detergents (bleach).
  • False negative: ascorbic acid (reducing agent), high ketones, salicylates, high SG, low temperature, and — the most common — unpreserved urine left at room temperature (glycolysis).

Clinitest — copper reduction

CuSO₄ (blue) + reducing substance --heat + alkali--> Cu₂O (orange-red) Detects ANY reducing sugar: glucose, galactose, lactose, fructose, pentoses (+ ascorbic acid, some drugs) Sensitivity ≈ 200 mg/dL glucose (less sensitive than the strip) SUCROSE (table sugar) is NON-reducing → negative in both tests
  • Pass-through: at very high sugar the color passes orange and returns to green-brown → falsely low. Watch the reaction; repeat with the 2-drop method (2 drops urine + 10 drops water = 1:6 dilution; chart to 5 g/dL).
  • Main use today: screen infants (up to ~2 years) for galactosuria (galactosemia — failure to thrive, vomiting after milk).
  • Tablets are hygroscopic; reaction tube gets very hot (use a rack).
Glucose oxidase stripClinitestInterpretation
PositivePositiveGlucose present (true glycosuria)
1+ positiveNegativeSmall amount of glucose (Clinitest less sensitive)
4+ positiveNegativeSuspect oxidizing-agent contamination of the strip
NegativePositiveNon-glucose reducing sugar (galactose in a newborn; lactose in pregnancy/lactation) or strip interference (ascorbic acid)

Ketones

Ketones come from incomplete fat metabolism when carbohydrate cannot be used (DM) or is not available (starvation, vomiting, low-carb diet, strenuous exercise, child with vomiting/diarrhea).

Proportions in urine: β-hydroxybutyric acid ≈ 78% acetoacetic acid ≈ 20% acetone ≈ 2% Nitroprusside reacts with: ACETOACETIC ACID (main) + acetone (only if glycine present) Does NOT react with: β-HYDROXYBUTYRIC ACID
⚠️ EXAM TRAP — In severe diabetic ketoacidosis (DKA) with acidosis, most ketone is β-hydroxybutyrate → the nitroprusside test underestimates ketosis. Measure serum β-hydroxybutyrate enzymatically.
  • False positive: phthalein dyes (PSP/BSP), highly pigmented red urine, levodopa, drugs with free sulfhydryl groups (MESNA, captopril); phenylketones (PKU) in the classic tube test.
  • False negative: improperly preserved urine (acetone evaporates, bacteria break down acetoacetate).
  • Acetest tablet (nitroprusside + glycine + disodium phosphate + lactose) — also usable on serum; serial dilutions in severe ketosis.
  • Ketonuria is NOT caused by renal failure or by bacterial infection.
🧠 MEMORY TRICK — Glucose positive + ketones positive = type 1 DM / DKA. Glucose NEGATIVE + ketones positive = starvation, vomiting, dieting.

📚 Book check — added from the two review books

  • Strip glucose detects about 100 mg/dL (≈0.1%). Clinitest detects about 150–200 mg/dL (≈0.2%). The two books give slightly different Clinitest values. (Hubbard Ch.9, pp.325, 327; 6.0 p.86)
  • The Clinitest tablet contains copper sulfate, sodium hydroxide, sodium carbonate and citric acid. The reaction makes its own heat and boils. 5-drop method: 5 drops urine + 10 drops water + 1 tablet; 15 seconds after the boiling stops, mix gently and read. Blue = negative; green → orange = more sugar. Pass-through happens above about 2 g/dL. (Hubbard Ch.9, pp.326–327)
  • Non-glucose sugars (strip −, Clinitest +): lactose (late pregnancy, lactation), pentose (after eating certain fruits), fructose (parenteral fructose feeding), galactose (galactosemia). Inherited enzyme defects can also cause them. (Hubbard Ch.9, p.327)
  • The ketone strip detects about 5–10 mg/dL acetoacetic acid (maroon/purple color). It does not detect β-hydroxybutyrate, but the three ketone bodies are excreted together. (Hubbard Ch.9, pp.324–326)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.5, pp.61–66; Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, pp.352.e3–352.e4; Medical Laboratory Science Review (Harr), Ch.6, pp.336–338, Q37–Q45; BOC Study Guide, 6th ed., Ch.2, pp.91–93 Q47–Q55, Q65, Q67; SUCCESS! in Clinical Laboratory Science, Ch.11, Q15–Q16, Q31, Q59, Q66 (pp.937–944); DoH Past Paper Exam — Chemistry, p.9 Q51, p.13 Q20, p.16 Q44.

📌 MUST MEMORIZE

9 · Blood: hematuria vs hemoglobinuria vs myoglobinuria

📚 Why this section: Calendar (Urinalysis I) items: Blood · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §IV B 3c Blood (p.325); Table 9–3 (p.324) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Blood (p.86)

STRIP: heme has PSEUDOPEROXIDASE activity H₂O₂ (peroxide) + tetramethylbenzidine --heme--> oxidized TMB (green-blue) Intact RBCs lyse on the pad → SPECKLED / spotted pattern = HEMATURIA Free hemoglobin or myoglobin → UNIFORM color = HEMOGLOBINURIA / MYOGLOBINURIA Very sensitive: ≈ 5 RBCs/µL — more sensitive than the protein pad to hemoglobin
HematuriaHemoglobinuriaMyoglobinuria
Urine lookCloudy redClear redClear red-brown
RBCs on microscopyPresentAbsent (or few)Absent
PlasmaNormalRed/pink (Hb–haptoglobin stays in blood); haptoglobin ↓Clear (myoglobin cleared fast); CK ↑↑
CausesRenal calculi, glomerulonephritis, pyelonephritis, tumors, trauma, anticoagulants, exercise, catheterization, menstruationIntravascular hemolysis: transfusion reaction, hemolytic anemia, burns, malaria, PNH; RBC lysis in dilute alkaline urineRhabdomyolysis: crush injury, trauma, prolonged coma, convulsions, alcohol/drugs, statins, extreme exertion
80% ammonium sulfate—Hb precipitates → supernatant blood-negativeMb stays in solution → supernatant red and blood-positive
🔥 VERY HIGH-YIELD — Blood pad POSITIVE but NO RBCs: (1) RBCs lysed in dilute (low SG) or alkaline urine, (2) hemoglobinuria (intravascular hemolysis), (3) myoglobinuria (crush injury). Blood pad NEGATIVE but RBCs "seen": the cells are probably yeast (check with acetic acid — RBCs lyse) — or a false-negative from ascorbic acid.
  • False positive: strong oxidizing detergents (bleach), bacterial peroxidases (E. coli), vegetable peroxidase, menstrual contamination.
  • False negative: ascorbic acid (>25 mg/dL), high SG (crenated RBCs do not lyse), formalin, captopril, high nitrite, unmixed specimen.
  • Extravascular hemolysis gives ↑ urobilinogen but a negative blood pad (no free Hb filtered).
  • Reabsorbed Hb → hemosiderin granules in tubular cells (Prussian blue stain) a few days later.

📚 Book check — added from the two review books

  • Blood pad sensitivity: about 5–20 RBCs/µL, or 0.05–0.3 mg/dL free hemoglobin. The chromogen is tetramethylbenzidine or o-toluidine, and the color goes from green to dark blue. A normal result is negative. (Hubbard Ch.9, pp.324–325)
  • Strenuous exercise can cause all three: hematuria, hemoglobinuria and myoglobinuria. (6.0 p.86; Hubbard Ch.9, p.319)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.5, pp.65–67; Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, p.352.e3; Medical Laboratory Science Review (Harr), Ch.6, pp.338–339 Q46–Q50, p.372 Q8, p.375 Q16–Q17; BOC Study Guide, 6th ed., Ch.2, p.92 Q58, p.93 Q64; SUCCESS! in Clinical Laboratory Science, Ch.11, Q17 (p.937), Q34 (p.940).

🔥 VERY HIGH-YIELD

10 · Bilirubin and urobilinogen — reading jaundice from the urine

📚 Why this section: Calendar (Urinalysis I) items: Bilirubin; Urobilinogen · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §IV B 3g–h Bilirubin and Urobilinogen (p.326); §IV C 3 Ictotest (p.327) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Bilirubin; Urobilinogen; Normal bilirubin metabolism (pp.86–87)

Old RBCs → hemoglobin → UNCONJUGATED bilirubin (bound to albumin, NOT water soluble → NOT in urine) → liver conjugates with glucuronic acid → CONJUGATED bilirubin (water soluble → CAN appear in urine) → bile → intestine → bacteria → UROBILINOGEN (+ stercobilinogen) most → urobilin → brown stool some reabsorbed → liver → small amount filtered into urine (≤ 1 mg/dL = 1 Ehrlich unit)
ConditionUrine bilirubinUrine urobilinogenWhy
Bile duct obstruction (gallstone, carcinoma)POSITIVE (++)Normal / ↓ (absent)Conjugated bilirubin backs up into blood; bile cannot reach gut → no urobilinogen; pale (clay) stool
Liver damage (hepatitis, cirrhosis)Positive↑ (or normal)Damaged cells leak conjugated bilirubin and cannot clear recycled urobilinogen
Hemolytic disease (prehepatic)NEGATIVE↑↑Excess bilirubin is UNCONJUGATED (cannot pass into urine) → more urobilinogen made
🧠 MEMORY TRICK — "Hemolysis HIDES bilirubin (negative) but shouts urobilinogen. Obstruction BLOCKS urobilinogen but floods bilirubin." Bilirubin in urine = conjugated only = liver or bile-duct problem.

Bilirubin tests

  • Strip: diazo reaction (2,4-dichloroaniline or 2,6-dichlorobenzene diazonium salt) → tan/pink-violet. Sensitivity ≈ 0.4 mg/dL.
  • Ictotest tablet: more sensitive (0.05–0.1 mg/dL), less interference → confirm a positive or questionable strip, detect early hepatitis. Special mat keeps bilirubin on its surface; blue-purple = positive.
  • False negative: light exposure (photo-oxidized to biliverdin — the most common error), old urine (hydrolysis to free bilirubin), ascorbic acid, high nitrite.
  • False positive: pigmented urine (phenazopyridine), indican, metabolites of Lodine (etodolac).
  • Specimens for bilirubin: fresh, protected from light. Yellow foam on shaking.

Urobilinogen tests

  • Multistix: Ehrlich reaction — p-dimethylaminobenzaldehyde → pink-red (reported in Ehrlich units = mg/dL; normal 0.2–1). Chemstrip: diazo (more specific).
  • Strips cannot detect the ABSENCE (decrease) of urobilinogen → that is why "never reported as negative".
  • Highest excretion 2–4 p.m. → 2-hour afternoon specimen. Also ↑ after heavy meals and with constipation.
  • False positive (Ehrlich-reactive compounds): porphobilinogen, indican, p-aminosalicylic acid, sulfonamides, methyldopa, procaine, chlorpromazine; pigmented urine. False negative: old specimen (oxidized to urobilin), formalin, high nitrite (Chemstrip).
Watson-SchwartzChloroform layerButanol layer
UrobilinogenRed (extracted)Red (extracted)
Other Ehrlich-reactive compoundsColorlessRed (extracted)
PorphobilinogenColorlessColorless — not extracted by either

Hoesch test (Ehrlich reagent in 6 M HCl) screens/monitors porphobilinogen; urobilinogen is inhibited by the strong acid.

📚 Book check — added from the two review books

  • Normal urobilinogen excretion is up to 4 mg/24 h (≈1 mg/dL = 1 EU in a random urine). The strip reads 0.2–8 EU. (Hubbard Ch.9, pp.314, 324, 326)
  • Ictotest steps: 5 drops of urine on the special mat → put the tablet on the wet area → 2 drops of water run over the tablet onto the mat. Blue-purple on the mat within 60 seconds = positive. A pink or red color = negative. (Hubbard Ch.9, p.327)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.5, pp.68–72, Tables 5–3 and 5–4; Medical Laboratory Science Review (Harr), Ch.6, pp.339–340 Q51–Q53, p.374 Q14; BOC Study Guide, 6th ed., Ch.2, pp.85, 92–93, Q2, Q4, Q56–Q57, Q63; SUCCESS! in Clinical Laboratory Science, Ch.11, Q8, Q60–Q61 (pp.936, 943).

📌 MUST MEMORIZE

11 · Nitrite and leukocyte esterase — screening for urinary tract infection (UTI)

📚 Why this section: Calendar (Urinalysis I) items: Nitrite; Leukocyte esterase · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §IV B 3i–j Leukocytes and Nitrite (p.326) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Nitrite; Leukocytes (p.87)

NITRITE (Greiss reaction) Gram-negative bacteria (Enterobacterales: E. coli, Proteus, Klebsiella…) have REDUCTASE Dietary NITRATE (in urine) --bacterial reductase--> NITRITE Nitrite + p-arsanilic acid (or sulfanilamide) → diazonium salt + benzoquinoline → PINK azodye Standardized ≈ 100,000 (10⁵) organisms/mL · ANY pink = POSITIVE (does not measure amount)
Nitrite FALSE NEGATIVE (common!)Nitrite FALSE POSITIVE
Bacteria without reductase: gram-positive (Enterococcus, Staphylococcus), yeast, Trichomonas · urine in bladder < 4 hours (random specimen, frequent voiding, children) · no dietary nitrate (no vegetables) · very heavy infection reduces nitrite further to nitrogen · antibiotics · ascorbic acid · high SGOld unpreserved urine (contaminating bacteria multiply in the cup) · highly pigmented urine (pink edges are not positive)
🔥 VERY HIGH-YIELD — Nitrite needs THREE things: (1) nitrate-reducing bacteria, (2) dietary nitrate, (3) ≥4 hours incubation in the bladder → best specimen = first morning urine. Bacteria added at collection time cannot make nitrite immediately.

Leukocyte esterase (LE)

  • Detects esterase in granulocytes (neutrophils, eosinophils, basophils) and monocytes; also Trichomonas and histiocytes. NOT lymphocytes, RBCs, bacteria or renal cells.
  • Advantage: detects lysed WBCs (dilute alkaline urine) that microscopy misses. Sensitivity ≈ 5–15 WBC/hpf. Longest reaction: 2 minutes.
  • False positive: strong oxidizing agents, formalin, pigmented urine, nitrofurantoin.
  • False negative: high protein (>500 mg/dL), high glucose (>3 g/dL), high SG (crenated WBCs), oxalic acid, ascorbic acid, antibiotics (gentamicin, cephalexin, cephalothin, tetracycline), inaccurate timing.
  • LE + nitrite together screen which urines need culture; LE contributes more than nitrite. Both negative helps "rule out" UTI.
⚠️ EXAM TRAP — Nitrite POSITIVE but LE NEGATIVE → think of an old specimen (bacteria grew in the cup after collection; no true infection with WBCs). A true UTI usually has a positive LE. A strongly positive nitrite with no bacteria and no WBCs in a drug-screen specimen → adulterant (nitrite added to mask drugs).

📚 Book check — added from the two review books

  • In the Multistix LE pad, leukocyte esterase hydrolyses a pyrrole amino acid ester to a pyrrole. The pyrrole then reacts with a diazonium salt → purple. (Chemstrip uses an indoxyl ester.) (Hubbard Ch.9, p.326; 6.0 p.87)
  • LE can be falsely positive from vaginal contamination (vaginal WBCs, trichomonads). (Hubbard Ch.9, p.326)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.5, pp.72–74; Tietz Textbook of Laboratory Medicine, 7th ed., Ch.34, p.352.e4; Medical Laboratory Science Review (Harr), Ch.6, p.340 Q54–Q55, p.371 Q2, p.379 Q31; SUCCESS! in Clinical Laboratory Science, Ch.11, Q32 (p.939), Q67 (p.944); DoH Past Paper Exam — Chemistry, p.1, Q3.

⚠️ VERIFIED

12 · Interferences, result correlation, and top traps

📚 Why this section: Calendar (Urinalysis I) items: False-positive/false-negative reactions; Important interferences · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §II B 8e Potential inaccuracies (p.317) and Table 9–3 Affecting factors (p.324) · Check book: Clinical Laboratory Science Review, 5th ed., Urinalysis — Reagent strip reactions: false positive / false negative (p.88); Strip correlations (p.87)

Ascorbic acid (vitamin C) — the classic reducing agent

🔥 VERY HIGH-YIELD — Large doses of vitamin C cause FALSE-NEGATIVE (falsely LOW) results for blood, glucose, bilirubin, nitrite and leukocyte esterase (it uses up peroxide or reduces the diazonium salt). It does NOT affect protein, pH or SG. In the copper reduction test (Clinitest) it can give a false POSITIVE.

Correlate the results (they must "agree")

FindingShould go withIf not → think
Positive nitritePositive LE, bacteria, WBCs, often alkaline pHOld specimen; adulterant
Positive bloodRBCs on microscopyLysis (dilute/alkaline), Hb or Mb
RBCs seenPositive blood padYeast mistaken for RBCs; ascorbic acid
Positive proteinCasts, bloodAlkaline false positive; orthostatic
Positive bilirubinDark yellow/amber urine, yellow foamPhenazopyridine; light-exposed specimen
Glucose + ketonesType 1 DMKetones alone → starvation/vomiting
Dark yellow colorHigh SGPigment (bilirubin, drug) if SG low

Top traps for this topic

  • Filtrate SG 1.010 · fixed 1.010 = isosthenuria · <1.003 = not urine · >1.035 = X-ray dye → use strip SG or osmolality.
  • Refractometer: water 1.000, 5% NaCl 1.022, 9% sucrose 1.034; temperature-compensated; subtract 0.003/g protein, 0.004/g glucose.
  • Strip SG: ions only (no glucose/protein/dye effect); add 0.005 if pH ≥6.5.
  • Protein strip = albumin only; false + alkaline; SSA = all proteins; strip −/SSA + = Bence Jones.
  • Nitroprusside = acetoacetic acid (± acetone), never β-hydroxybutyrate.
  • Glucose oxidase specific; Clinitest any reducing sugar (not sucrose); pass-through → 2-drop.
  • Speckled blood pad = intact RBCs; uniform = Hb/Mb; ammonium sulfate precipitates Hb, not Mb.
  • Hemolysis: bilirubin −, urobilinogen ↑. Obstruction: bilirubin +, urobilinogen ↓. Bilirubin → protect from light → Ictotest.
  • Nitrite: gram-negative, nitrate diet, 4 h in bladder. LE: not lymphocytes; read at 2 min.
  • Standing urine: pH, nitrite, bacteria ↑; glucose, ketones, bilirubin, urobilinogen, cells ↓. Test within 2 h or refrigerate.
  • Delayed more than 2 h → refrigerate (2–8 °C); boric acid is mainly a culture-transport preservative.
  • Cloudy after refrigeration = amorphous urates (acid) or phosphates (alkaline). Dissolved protein or glucose does not make urine cloudy; turbidity means particles.
  • Drug-screen validity = temperature, pH, SG and creatinine (plus adulterant tests); leukocyte esterase is not a validity test.

📚 Book check — added from the two review books

  • Newer reagent strips resist ascorbic acid (vitamin C) much better. Older strips were inhibited at about ≥5 mg/dL ascorbic acid for blood, ≥25 mg/dL for nitrite and ≥50 mg/dL for glucose. (6.0 pp.86–88; Hubbard Ch.9, p.324)
  • Highly pigmented urine (for example phenazopyridine, levodopa metabolites) makes the pad colors hard to read. It can give false-positive ketone and urobilinogen results. (Hubbard Ch.9, p.323; 6.0 p.88)
  • Common causes of urinalysis errors: wrong collection, handling or specimen identity; ignoring procedures or expiry dates; not using the color chart; not following instrument instructions; weak QC; and expecting tests based on different methods to agree (for example strip protein vs SSA, or strip SG vs refractometer). (Hubbard Ch.9, p.317)
  • Strip correlation partners: glucose ↔ ketones · bilirubin ↔ urobilinogen · blood ↔ protein + microscopy · nitrite and LE ↔ protein + each other + microscopy · pH ↔ nitrite, LE, microscopy · SG ↔ none. (6.0 p.87)

Sources: Urinalysis and Body Fluids, 5th ed. (Strasinger & Di Lorenzo), Ch.3 (pp.33–37), Ch.4 (pp.46–48), Ch.5 (pp.59–73); Medical Laboratory Science Review (Harr), Ch.6, p.334 Q28, p.335 Q33, pp.378–379 Q30–Q31.

BOOK CHECK

13 · Urinalysis automation — strip readers and sediment analyzers

📚 Why this section: Calendar (Urinalysis I) items: Chemical strip testing (automated readers); Specific gravity (harmonic oscillation) · Book framework: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §VI Automation in the urinalysis laboratory (p.335) · Check book: Clinical Laboratory Science Review, 5th ed., Laboratory Operations — Urinalysis instrumentation; Flow cytometry (p.242)

Many laboratories no longer read strips by eye or count every sediment particle by microscope. Instruments do it. The exam usually asks one thing: which principle measures which part of the urinalysis?

  • Levels of automation: single strip readers → semi-automated → fully automated analyzers → complete urinalysis workstations (chemistry + sediment).
  • Analyzers named in the check book: Clinitek (Siemens) and Urisys (Roche) — strip readers; iQ200 (IRIS) — digital-imaging sediment; UF-1000i (Sysmex) — flow-cytometry sediment.

1. Automated strip readers — reflectance photometry

  • Light shines on each reagent pad → the colored pad absorbs part of it → a detector measures the light that is reflected.
  • The reflected light is compared with a known standard → the analyzer shows the concentration and its units.
  • Darker color (more analyte) → LESS reflected light. Reflected light falls in direct proportion to the color intensity.
🧠 MEMORY TRICK: Color goes UP → reflectance goes DOWN. A dark pad "swallows" the light.

2. Specific gravity in analyzers — harmonic oscillation densitometry

  • A sound wave of a set frequency passes through the urine. Its frequency changes in proportion to the urine density, and a microprocessor converts the change to SG (see Section 5).

3. Sediment — flow cytometry

  • Sheath fluid focuses the particles into a single-file stream in the flow cell (hydrodynamic focusing).
  • Impedance (conductivity): each particle passing through an electrical field makes one pulse. Number of pulses = count; size of the pulse = size of the particle.
  • Laser light scatter: forward scatter (diffraction + refraction) mainly shows size; side scatter (detector at 90°, reflection) shows granularity / internal complexity. Particles are identified by how they scatter light (and by fluorescence when stains are used).

4. Sediment — digital imaging (flow microscopy)

  • Hydrodynamic focusing moves the particles one by one past a microscope objective; the flow cell also measures size, conductivity and light scatter.
  • Software classifies the particles. Questionable particles are shown on a monitor so the operator can identify and confirm them.
Part of the urinalysisAutomated principleManual method
Reagent strip colorsReflectance photometryEye vs color chart
Specific gravityHarmonic oscillation densitometry (or the strip SG pad)Refractometer, urinometer
Sediment count / identificationFlow cytometry (impedance + laser scatter) or digital imagingMicroscopy
🔥 VERY HIGH-YIELD: Strips = reflectance photometry · SG = harmonic oscillation · Sediment = flow cytometry / impedance or digital imaging.
⚠️ EXAM TRAP: Automation does NOT remove quality control. Run controls each day of use, follow the manufacturer's instructions, and record the results. Flagged or questionable results need operator review (and manual microscopy when needed). Highly pigmented urine still makes pad colors hard to read.
🔬 LAB CONNECTION: Advantages of readers: the same reading time and color judgment for every strip (no room-lighting or staff differences), speed, and results sent straight to the LIS (fewer transcription errors).

Sources: A Concise Review of Clinical Laboratory Science (Hubbard), Ch.9 §VI Automation in the urinalysis laboratory (p.335); §II B 4 QC of automated equipment (p.316); §IV B 2 pigmented urine (p.323); Clinical Laboratory Science Review, 5th ed., Laboratory Operations — Urinalysis instrumentation; Flow cytometry (p.242). Advantages of automation and the need to review flagged results = current standard practice.